Simple, cheap, sensitive, and accurate kinetic- spectrophotometric method has been developed for the determination of naringenin in pure and supplements formulations. The method is based on the formation of Prussian blue. The product dye exhibits a maximum absorbance at 707 nm. The calibration graph of naringenin was linear over the range 0.3 to 10 µg ml-1 for the fixed time method (at 15 min) with a correlation coefficient (r) and percentage linearity (r2%) were of 0.9995 and 99.90 %, respectively, while the limit of detection LOD was 0.041 µg ml-1. The method was successfully applied for the determination of naringenin in supplements with satisfactory results.
- Identifying the visual culture skills of students of the College of Education for Pure Sciences / Ibn Al-Haytham.
- Identifying the statistically significant differences in the visual culture skills of students of the College of Education for Pure Sciences / Ibn Al-Haytham according to the gender variable.
And the descriptive approach was used, due to its relevance to the nature of the research objective.
To verify this, the visual culture skills test consisted of (22) items of the multiple choice type, where the (Koder Richardson 20) equation was applied to calculate the stability of the visual culture skills test. For the skill of writing
The current work was undertaken to obtain the crude extract of PPO and laccase enzyme from the leaves of Malva parviflora. All leaves were washed with tap water, then the extraction was performed to acquire the crude extract’s enzymes. One gram of Malva parviflora leaves was homogenized in various volumes of distilled water (1:10, 1:5, and 1:2 w: v). The results showed that polyphenol oxidase and laccase with a ratio of 1:10 (w:v) gave the highest specific activity of 112.3 with 0.394 U/mg proteins. In addition, Malva parviflora leaves were homogenized with several types of buffers with two concentration (0.2 and 0.1 M) for PPO and laccase extraction. These buffers were potassium
... Show MoreNew chlropheniramine maleate (CPM) selective electrochemical membranes were prepared by using chlropheniramine maleate -molecularly imprinted polymers. MIP was prepared by bulk polymerization using 2-hydroxyethyl methacrylate (2-HEMA) as monomer, ethylene glycol dimethacrylate (EGDMA) as a cross-linker and a benzoyl peroxide (BPO) as an initiator at 600C. Three CPM-MIP electrodes were constructed by using tri-tolyl Phosphate (ToCP), tris (2- ethyl hexyl) Phosphate (TEHP) and tributyl Phosphate (TBP) as plasticizers in PVC matrix.Electrode parameters including slopes, working concentrations ph. The interference effect in the presence of (Na+, Mg+2, Al+3, Glycine, Alanine, Arginine and Phenylalanine) was studied using the separated a
... Show MoreIn the present work , radon concentration was measured indoor buildings in the College of Education for Pure Science/ Ibn Al- Haitham University of Baghdad using detector (CR-39) by counting track of alpha resulting from decay series of uranium on the detectors which have exposure to air inside the rooms for (30) days , have been applied the equation (1) and (2) to calculate concentrations of Radon and the results showed that all samples were within the allowable range globally except two samples F1 and F2 where concentrations were (445.868Bq/m3) and (436.791Bq/m3) respectively , they were higher than allowable range globally which was (200-300) Bq/m3 recorded by (ICRP) [1] .
In this study, gamma ray transmission method have been used to determine the total porosity in four samples: pure Alumina ( Al2O3 ), Al2O3 + (0.2wt%)MgO , Al2O3 + (0.6wt% )Y2O3 and Al2O3+ (8wt% ) ZrO2 .
The experimental setup for the gamma ray transmission consist of 137Cs gamma source ( 662 KeV ), a NaI (Tl) scintillation detector measured the attenuation of strongly collimated gamma beam through alumina samples.
The porosity obtained by the gamma ray transmission method were compare
... Show MoreAbstract
This paper is an experimental work to determinate the effect of welding velocity and formed arc energy for CO2-MAG fusion weld pool. The input parameters (arc voltage, wire feed speed and gas flow rate) were investigated to find their effects on the weld joint efficiency. Design of experiment with response surface methodology technique was used to build empirical mathematical models for welding velocity and arc energy in term of the input welding parameters. The predicted quadratic models were statistically checked for adequacy purpose by ANOVA analysis. Additionally, numerical optimization was conducted to obtain the optimum values for welding velocity and arc energy. A good agree
... Show MoreThis paper investigates a new approach to the rapid control of an upper limb exoskeleton actuator. We used a mathematical model and motion measurements of a human arm to estimate joint torque as a means to control the exoskeleton’s actuator. The proposed arm model is based on a two-pendulum configuration and is used to obtain instantaneous joint torques which are then passed into control law to regulate the actuator torque. Nine subjects volunteered to take part in the experimental protocol, in which inertial measurement units (IMUs) and a digital goniometer were used to measure and estimate the torque profiles. To validate the control law, a Simscape model was developed to simulate the arm model and control law in which measurem
... Show MoreIn this work Different weight of pure Zinc powder suspended particles in 4ml base engine Oil were used.
Intensity of Kα Line was measured for the suspended particles ,also for mixture which consist from Zinc particle blended with Engine base Oil. Calibration Curve was drawn between Ikα line Intensity and Zinc concentration at different operation condition. The Lower Limit detection (LLD) and Sensitivity (m) of Spectrometer were determined for different Zinc Concentration (Wt%). The results of LLD and m for Samples were analyzed at Operation Condition of 30KV,17mA is best from Samples were analyzed at Operation Condition of 25KV,15mA