In this research, the electrical characteristics of glow discharge plasma were studied. Glow discharge plasma generated in a home-made DC magnetron sputtering system, and a DC-power supply of high voltage as input to the discharge electrodes were both utilized. The distance between two electrodes is 4cm. The gas used to produce plasma is argon gas which flows inside the chamber at a rate of 40 sccm. The influence of work function for different target materials (gold, copper, and silver), - 5cm in diameter and around 1mm thickness - different working pressures, and different applied voltages on electrical characteristics (discharge current, discharge potential, and Paschen’s curve) were studied. The results showed that the discharge current and potential increase by increasing the applied voltage ranging between 300-700 V. Discharge current increased as working pressure increased in the beginning, and then semi-stabilized (slight increase) starting from 1×100 mbar, while discharge potential decreased at the beginning as working pressure increased and then semi-stabilized at the same point at which discharge current stabilized. The Paschen’s curves were compared with each other. It was concluded that the lower breakdown voltage was associated with lower work function of the (Au, Cu, and Ag) cathode material. Breakdown voltages were (395, 398, and 420) for Ag, Cu and Au respectively.
The fauna of bees (Hymenoptera, Apoidea) from different regions of Iraq is surveyed in this study; there were 16 species, 13 genera that belong to four families which are collected in this investigation.
Also, all the species that are recorded for Iraq in previous investigations are revised; totally there are 110 species, 32 genera belonging to five families: Apidae, Andernidae, Colletidae, Halictidae and Megachilidae were listed.
Introduction: The use of screw-retained hybrid arch bars (HABs) is a relatively recent development in the treatment of mandibular fractures. The purpose of this study is to compare the clinical outcome between HAB and the conventional Erich arch bar (EAB) in the closed treatment of mandibular fractures. Materials and methods: This study included 18 patients who were treated for mandibular fractures with maxillomandibular fixation (MMF), patients were randomly assigned into a control group (n = 10) in which EAB was used and study group (n = 8) in which HAB was used. The outcome variables were time required for application and removal, gingival inflammation scores, postoperative complications, and incidence of wire-stick injury or gloves perf
... Show MoreThis research is based on the descriptive and analytical methodology. The importance of studying labor laws and labor unions in Japan between 1889 and 1946 constitutions is because Japan was out of a feudal phase, and had no idea about the factory system and industrialization in their modern sense before the Meiji era. Generally, its labor system used to be mostly familial, and the economic system was based on agriculture. This called for the enactment of legislations and laws appropriate for the coming phase in Meiji era. Thus, this paper examines the role of Meiji government in enacting labor legislations and laws when he came to power in 1896, and his new constitution in 1889 and the civil code of 1896. It further examines the way Mei
... Show MoreIn the present work, different thicknesses of CdS film were prepared by chemical bath deposition. Z-Scan technique was used to study the nonlinear refractive index and nonlinear absorption coefficients. Linear optical testing were done such as transmission test, and thickness of films were done by the interference fringes (Michelson interferometer). Z-scan experiment was performed at 650nm using CW diode laser and at 532nm wavelength. The results show the effect of self-focusing and defocusing that corresponds with nonlinear refraction n2. The effect of two-photon absorption was also studied, which correspond to the nonlinear absorption coefficient B.
Background/purpose: Dental implantology involves different treatments that have been used in conjunction with dental implant surgery to increase implant stability and bone regeneration process. Photobiomodulation( PBM) can be one of these techniques. The objective of this study was to evaluate the bone density around implants. Materials and methods: in this study, 10 individuals had 20 implants inserted in the posterior of their mandibles. each patient received two implants the left side served as the control whereas the right side served as the study group with a diode laser (same patients). measurements were made for each implant. Measurements were obtained using cone-
... Show More