Spectrophotometric method was developed for the determination of copper(II) ion. Synthesized (2,2[O-Tolidine-4,4-bis azo]bis[4,5-diphenyl imidazole]) (MBBAI) was used as chromogenic reagent at pH=5. Various factors affecting complex formation, such as, pH effect, reagent concentration, time effect and temperature effect, have been considered and studied. Under optimum conditions concentration ranged from (5.00-80.00) µg/mL of copper(II) obeyed Beer`s Low. Maximum absorption of the complex was 409nm with molar absorpitivity 0.127x104 L mol-1 cm-1. Limit of detection(LOD) and Limit of quantification were 1.924 and 6.42 μg/mL, respectively. The stoichiometric composition of the chelate is 1:2 (Cu:MBBAI). Experimental results for studying some selected ions as interference were reported. The developed method was successfully applied to determine copper (II) ion in dental filling.
Background: Diabetic nephropathy (DN) is a significant contributor to end-stage renal failure in individuals with type 2 diabetes mellitus (T2DM). Diabetic nephropathy is characterized by tubular atrophy, glomerular dilation, glomerulosclerosis, interstitial fibrosis, and proteinuria, resulting in deterioration of kidney function. DN, primarily caused by hyperglycemia, accounts for millions of deaths globally and is the leading cause of end-stage renal disease. Matrix metalloproteinase 10 is an enzyme essential for the breakdown of extracellular matrix constituents. Fetuin-A forms soluble complexes with calcium and phosphate to prevent soft tissue mineralization Objectives: To determine the levels of Matrix Metalloproteinase 10 and
... Show MoreTo assess the contribution of Doppler broadening and examine the
Compton profile, the Compton energy absorption cross sections are
measured and calculated using formulas based on a relativistic
impulse approximation. The Compton energy-absorption cross
sections are evaluated for different elements (Fe, Zn, Ag, Au and Hg)
and for a photon energy range (1 - 100 keV). With using these crosssections,
the Compton component of the mass–energy absorption
coefficient was derived, where the electron momentum prior to the
scattering event caused a Doppler broadening of the Compton line.
Also, the momentum resolution function was evaluated in terms of
incident and scattered photon energy and scattering angle. The res
In this paper, turbidimetric and reversed-phase ultra-fast liquid chromatography (UFLC) methods were described for the quantitative determination of ephedrine hydrochloride in pharmaceutical injections form. The first method is based on measuring the turbidimetric values for the formed yellowish white precipitate in suspension status in order to determine the ephedrine hydrochloride concentration. The suspended substance is formed as a result of the reaction of ephedrine hydrochloride with phosphomolybdic acid which was used as a reagent. The physical and chemical characteristics of the complex were investigated. The calibration graphs of ephedrine were established by turbidity method. While the second method (UFLC) was conducted using the
... Show MoreThe present study was conducted on 20 patients suffering from different types of lesion like
pyogenic granuloma, peripheral giant cell granuloma, mucoceles, pregnancy tumour, Fordyce's granules
and irritating fibroma.The cases were selected from outpatient clinic of the Al Kydhemya Teaching
Hospital. Patients were treated by diode laser (810±20 nm) at the affected areas of the oral cavity with
continuous contact focused mode until excision of the lesion with coagulation of the oozing area after
excision. Patients were followed up after 2 days, 7 days and 2 weeks to assess healing process and any
post operative complication. Some of undiagnosed lesion sent for histopathological examination. No
serious complications w
This research work aims to the determination of molybdenum (VI) ion via the formation of peroxy molybdenum compounds which has red-brown colour with absorbance wave length at 455nm for the system of ammonia solution-hydrogen peroxide-molybdenum (VI) using a completely newly developed microphotometer based on the ON-Line measurement. Variation of responses expressed in millivolt. A correlation coefficient of 0.9925 for the range of 2.5-150 ?g.ml-1 with percentage linearity of 98.50%. A detection limit of 0.25 ?g.ml-1 was obtained. All physical and chemical variable were optimized interferences of cation and anion were studied classical method of measurement were done and compared well with newly on-line measurements. Application for the use
... Show MoreMRP is a system intended for the batch manufacturing of discrete parts including assemblies and subassemblies that should be stocked to support future manufacturing needs. Due to the useful information provided by MRP it has evolved into a Manufacturing Resources Planning, MRP II, a system that ties the basic MRP system to the other functional areas of the company such as marketing, finance, purchasing, etc. The objective of this research, which was conducted at the State Company for Batteries Manufacturing, is to test the performance of some popular lot-sizing techniques used within MRP II framework. It is hypothesized that the technique which minimizes the total inventory costs does no
... Show MoreBackground: The size of the nasopharyngeal airway was believed to have an important role in the development of the dentofacial structure. This study was carried out to test the relation between the nasopharyngeal dimensions with some dento-cranial measurements in class I and II jaw relationship. Materials and Methods: This study was done on 60 subjects (30 males and 30 females) at age range 18-25 years. Cephalometric radiograph has been taken to each subject and the measurements were recorded. The sample was divided into two groups, class I skeletal relationship (15 males and 15 females) and class II skeletal relationship (15 males and 15 females). Comparisons between the different study groups were undertaken. Results: In class I skeletal
... Show MoreBackground: Recent studies suggest that chronic periodontitis (CP) and type2 diabetes mellitus (T2DM) are bidirectionally associated. Analysis of saliva as a mirror of oral and systemic health could allow identification of α amylase (α-Am) and albumin (A1) antioxidant system markers to assist in the diagnosis and monitoring of both diseases. The present study aims at comparing the clinical periodontal parameters in chronic periodontitis patients with poorly or well controlled Type 2Diabetes Mellitus, salivary α-Am, A1, flow rate (FR) and pH then correlate between biochemical, physical and clinical periodontal parameters of each study and control groups. Materials and Methods: 80 males, with an age range of (35-50) years were divide
... Show MoreBackground: The present study aimed to assess the distribution, prevalence, severity of malocclusion in Baghdad governorate in relation to gender and residency Materials and Methods: A multi-stage stratified sampling technique was used in this investigation to make the sample a representative of target population. The sample consisted of 2700 (1349 males and 1351 females) intermediate school students aged 13 years representing 3% of the total target population. A questionnaire was used to determine the perception of occlusion and orthodontic treatment demand of the students and the assessment procedures for occlusal features by direct intraoral measurement using veriner and an instrument to measure the rotated and displaced teeth. Results a
... Show More