Preferred Language
Articles
/
bsj-3467
New Fluorometric Method for the Determination of Ketotifen Fumarate Using Continuous Flow Injection Analysis via ISNAG-fluorimeter
...Show More Authors

        A newly developed analytical method was conducted for the determination of Ketotifen fumarate (KTF) in pharmaceuticals drugs via quenching of continuous fluorescence of 9(10H)-Acridone (ACD). The method was applied using flow injection system of a new homemade ISNAG fluorimeter with fluorescence measurements at ± 90◦ via 2×4 solar cell. The calibration graph was linear in the range of 1-45 mmol/L, with correlation coefficient r = 0.9762 and the limit of detection 29.785 µg/sample from the stepwise dilution for the minimum concentration in the linear dynamic ranged of the calibration graph. The method was successfully applied to the determination of Ketotifen fumarate in two different pharmaceutical drugs. A comparison was made between the newly developed method analysis and the classical method using the standard addition method via the use of individual and paired t-test and F-test. It was noticed that there was no significant difference between the two methods at 95 % confidence level.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed May 31 2023
Journal Name
International Journal Of Advanced Technology And Engineering Exploration
Investigation of phase change characteristics for refrigerant R-134a flow in a double pipe heat exchanger with the use of thermal non-equilibrium model
...Show More Authors

Almost all thermal systems utilize some type of heat exchanger. In a lot of cases, evaporators are important for systems like organic Rankine cycle systems. Evaporators give a share in a large portion of the capital cost, and their cost is significantly attached to their size or transfer area. Open-cell metal foams with high porosity are taken into consideration to enhance thermal performance without increase the size of heat exchangers. Numerous researchers have tried to find a representation of the temperature distribution closer to reality due to the different properties between the liquid and solid phases. Evaporation heat transfer in an annular pipe of double pipe heat exchanger (DPHEX) filled with cooper foam is investigated numerical

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Fri Jun 03 2022
Journal Name
International Journal Of Health Sciences
Corrosion risk assessment of the oil flow line in Southern Iraq
...Show More Authors

The risk assessment for three pipelines belonging to the Basra Oil Company (X1, X2, X3), to develop an appropriate risk mitigation plan for each pipeline to address all high risks. Corrosion risks were assessed using a 5 * 5 matrix. Now, the risk assessment for X1 showed that the POF for internal corrosion is 5, which means that its risk is high due to salinity and the presence of CO, H2S and POF for external corrosion is 1 less than the corrosion, while for Flowline X2 the probability of internal corrosion is 4 and external is 4 because there is no Cathodic protection applied due to CO2, H2S and Flowline X3 have 8 leaks due to internal corrosion so the hazard rating was very high 5 and could be due to salinity, CO2, fluid flow rate

... Show More
Preview PDF
Crossref
Publication Date
Tue Mar 30 2010
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Numerical study of the mixed convection flow over a square cylinder
...Show More Authors

In this work, a numerical study is performed to predict the solution of two – dimensional, steady and laminar mixed convection flow over a square cylinder placed symmetrically in a vertical parallel plate. A finite difference method is employed to solve the governing differential equations, continuity, momentum, and energy equation balances. The solution is obtained for stream function, vorticity and temperature as dependent variables by iterative technique known as successive over relaxation. The flow and temperature patterns are obtained for Reynolds number and Grashof number at (Re= -50,50,100,-100) (positive or negative value refers to aidding or opposing buoyancy , +1 assisting flow, -1 opposing flow) and (102 to 105) , respective

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 04 2018
Journal Name
Baghdad Science Journal
The Effect of Gas Flow on Plasma Parameters Induced by Microwave
...Show More Authors

In this paper, construction microwaves induced plasma jet(MIPJ) system. This system was used to produce a non-thermal plasma jet at atmospheric pressure, at standard frequency of 2.45 GHz and microwave power of 800 W. The working gas Argon (Ar) was supplied to flow through the torch with adjustable flow rate by using flow meter, to diagnose microwave plasma optical emission spectroscopy(OES) was used to measure the important plasma parameters such as electron temperature (Te), residence time (Rt), plasma frequency (?pe), collisional skin depth (?), plasma conductivity (?dc), Debye length(?D). Also, the density of the plasma electron is calculated with the use of Stark broadened profiles

View Publication Preview PDF
Scopus (19)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Sun Mar 01 2015
Journal Name
Baghdad Science Journal
Spectrophotometric determination of Phenylephrine hydrochloride and Salbutamol sulphate drugs in pharmaceutical preparations using diazotized Metoclopramide hydrochloride
...Show More Authors

A spectrophotometric method has been proposed for the determination of two drugs containing phenol group [phenylephrine hydrochloride (PHP) and salbutamol sulphate (SLB)] in pharmaceutical dosage forms. The method is based on the diazotization reaction of metoclopramide hydrochloride (MCP) and coupling of the diazotized reagent with drugs in alkaline medium to give intense orange colored product (?max at 470 nm for each of PHP and SLB). Variable parameters such as temperature, reaction time and concentration of the reactants have been analyzed and optimized. Under the proposed optimum condition, Beer’s law was obeyed in the concentration range of 1-32 and 1-14 ?g mL-1 for PHP and SLB, respectively. The limit of detection (LOD) and l

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Apr 19 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Separation and determination of poly aromatic hydrocarbons in vegetables samples in Baghdad city using HPLC Technique
...Show More Authors

The Reversed Phase High Performance Liquid Chromatography (RP-HPLC) has been used for the separation of Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage of the heavy water ,industrial trash and trash of oil colanders. -

... Show More
Publication Date
Sun Dec 04 2011
Journal Name
Baghdad Science Journal
Determination of Antibodies (IgG, IgM) against Toxoplasma gondii in Some Iraqi individuals by using ELISA technique
...Show More Authors

A total of 258 voluntary blood donors (males 101; females 157) in the age range of 18-52 yr among males and 18-55 yr among females were examined for Toxoplasma gondii antibodies (IgG), and (IgM) by immunological technique (Enzyme linked Immunosorbant Assay) during the period from March 2009 to April 2010. This study covered a wide range of factors including immunological, age ,sex , place of residence and symptoms that may have a possible relationship with toxoplasmosis. Results presented in this study showed clearly that 38 (14.7%) of individuals participated in this study having IgG Toxoplasma Ab, among those 10 samples (9.9%) were males and 28 samples (17.8%) were females. Moreover, we found the prevalence of IgM seropositivity in th

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Fri Dec 30 2016
Journal Name
International Journal Of Applied Chemistry
Spectrophotometric Determination of Co(II) by Using Ethyl Cyano(2-Methyl Carboxylate Phenyl Azo Acetate) (ECA)
...Show More Authors

A new simple and sensitive spectrophotometric method for the determination of trace amount of Co(II) in the ethanol absolute solution have been developed. The method is based on the reaction of Co(II) with ethyl cyano(2-methyl carboxylate phenyl azo acetate) (ECA) in acid medium of hydrochloric acid (0.1 M) givining maximum absorbance at ((λmax = 656 nm). Beer's law is obeyed over the concentration range (5-60) (μg / ml) with molar absorptivity of (1.5263 × 103 L mol-1 cm-1) and correlation coefficient (0.9995). The precision (RSD% ˂ 1%). The stoichiometry of complex was confirmed by Job's method which indicated the ratio of metal to reagent is (2:1). The studied effect of interference elements Zn(II), Cu(II), Na(I), K(I), Ca(II) and Mg

... Show More
Preview PDF
Publication Date
Wed Oct 12 2011
Journal Name
Journal Of Liquid Chromatography & Related Technologies
RAPID DETERMINATION OF SPHINGANINE AND SPHINGOSINE IN URINE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY USING MONOLITHIC COLUMN
...Show More Authors

A rapid high performance liquid chromatography method for the determination of sphinganine (Sa) and sphingosine (So) in urine samples by employing a silica-based monolithic column is described. The samples were first extracted using ethyl acetate and derivatized using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol. C20 sphinganine was used as internal standard. Under the optimized conditions, separation was achieved using a mixture of methanol:water (93:7, v/v), column temperature at 30°C, flow rate of 1 mL min−1, and an injection volume of 10 μL. Good linearity was obtained for Sa and So over the concentration range 20–500 ng mL−1(correlation coefficients ≥0.9978). The detection limits were 0.45 ng mL−1 for Sa and

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Aip Conference Proceedings
Determination of paracetemol in pharmaceutical preparations samples by spectrophotometer using meta phenylenediamine as a chromogenic agent
...Show More Authors

View Publication
Crossref (1)
Scopus Crossref