Preferred Language
Articles
/
bsj-3467
New Fluorometric Method for the Determination of Ketotifen Fumarate Using Continuous Flow Injection Analysis via ISNAG-fluorimeter
...Show More Authors

        A newly developed analytical method was conducted for the determination of Ketotifen fumarate (KTF) in pharmaceuticals drugs via quenching of continuous fluorescence of 9(10H)-Acridone (ACD). The method was applied using flow injection system of a new homemade ISNAG fluorimeter with fluorescence measurements at ± 90◦ via 2×4 solar cell. The calibration graph was linear in the range of 1-45 mmol/L, with correlation coefficient r = 0.9762 and the limit of detection 29.785 µg/sample from the stepwise dilution for the minimum concentration in the linear dynamic ranged of the calibration graph. The method was successfully applied to the determination of Ketotifen fumarate in two different pharmaceutical drugs. A comparison was made between the newly developed method analysis and the classical method using the standard addition method via the use of individual and paired t-test and F-test. It was noticed that there was no significant difference between the two methods at 95 % confidence level.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Sep 13 2018
Journal Name
Baghdad Science Journal
An Efficient Numerical Method for Solving Volterra-Fredholm Integro-Differential Equations of Fractional Order by Using Shifted Jacobi-Spectral Collocation Method
...Show More Authors

The aim of this article is to solve the Volterra-Fredholm integro-differential equations of fractional order numerically by using the shifted Jacobi polynomial collocation method. The Jacobi polynomial and collocation method properties are presented. This technique is used to convert the problem into the solution of linear algebraic equations. The fractional derivatives are considered in the Caputo sense. Numerical examples are given to show the accuracy and reliability of the proposed technique.

View Publication Preview PDF
Scopus (6)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Mar 01 2023
Journal Name
Evergreen
Combustion Characteristics of a Free Piston Engine Linear Generator using Various Fuel Injection Durations
...Show More Authors

View Publication
Scopus (6)
Crossref (2)
Scopus Crossref
Publication Date
Tue Oct 01 2024
Journal Name
Analytical And Bioanalytical Electrochemistry
New Electrochemical Sensors for Determination of Tamoxifen Based on Enhanced Polymer Nano Composite Deep Eutectic Solvent and Water Mixture as Ionophores
...Show More Authors

Scopus (6)
Scopus
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of Global Pharma Technology
A Modified Version of Generalized Standard Addition Method as Quantitative Determination of Lysineacetyl salicylate-Glycine Complex
...Show More Authors

Scopus
Publication Date
Sat Feb 09 2019
Journal Name
Journal Of The College Of Education For Women
Shadow Removal Using Segmentation Method
...Show More Authors

Shadow detection and removal is an important task when dealing with color outdoor images. Shadows are generated by a local and relative absence of light. Shadows are, first of all, a local decrease in the amount of light that reaches a surface. Secondly, they are a local change in the amount of light rejected by a surface toward the observer. Most shadow detection and segmentation methods are based on image analysis. However, some factors will affect the detection result due to the complexity of the circumstances. In this paper a method of segmentation test present to detect shadows from an image and a function concept is used to remove the shadow from an image.

View Publication Preview PDF
Publication Date
Mon Jun 01 2009
Journal Name
Journal Of Economics And Administrative Sciences
Suggested method for modifying the site parameter
...Show More Authors

     Estimating multivariate location and scatter with both affine equivariance and positive break down has always been difficult. Awell-known estimator which satisfies both properties is the Minimum volume Ellipsoid Estimator (MVE) Computing the exact (MVE) is often not feasible, so one usually resorts to an approximate Algorithm. In the regression setup, algorithm for positive-break down estimators like Least Median of squares typically recomputed the intercept at each step, to improve the result. This approach is called intercept adjustment. In this paper we show that a similar technique, called location adjustment, Can be applied to the (MVE). For this purpose we use the Minimum Volume Ball (MVB). In order

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
International Journal Of Nonlinear Analysis And Applications
Big data analysis by using one covariate at a time multiple testing (Ocmt) method: Early school dropout in iraq
...Show More Authors

Scopus (13)
Scopus
Publication Date
Sun Jun 07 2009
Journal Name
Baghdad Science Journal
The adsorption-desorption process as a method for separation of nitrogen-carbon dioxide gas mixture using activated carbon
...Show More Authors

Gas adsorption phenomenon on solid surface has been used as a mean in separation and purification of gas mixture depending on the difference in tendencies of each component in the gas mixture to be adsorbed on the solid surface according to its behaviour. This work concerns to study the possibilities to separate the gas mixture using adsorption-desorption phenomenon on activated carbon. The experimental results exhibit good separation factor at temperature of -40 .

View Publication Preview PDF
Crossref
Publication Date
Wed Sep 30 2020
Journal Name
Association Of Arab Universities Journal Of Engineering Sciences
Estimation of Minimum Miscibility Pressure for Hydrocarbon Gas Injection Based on EOS
...Show More Authors

The important parameter used for determining the probable application of miscible displacement is the MMP (minimum miscibility pressure). In enhanced oil recovery, the injection of hydrocarbon gases can be a highly efficient method to improve the productivity of the well especially if miscibility developed through the displacement process. There are a lot of experiments for measuring the value of the miscibility pressure, but they are expensive and take a lot of time, so it's better to use the mathematical equations because of it inexpensive and fast. This study focused on calculating MMP required to inject hydrocarbon gases into two reservoirs namely Sadi and Tanomaa/ East Baghdad field. Modified Peng Robenson Equation of State was

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Tue May 23 2023
Journal Name
Journal Of Engineering
Injection Temperature Effects on the Properties of High Density Polyethylene Crates
...Show More Authors

This study was undertaken to provide more insight on the optimum injection temperature used for the production of PE crates, thereby saving time and money, and improving part quality. The work included processing trails of HDPE crates in an injection
molding machine at five temperatures ranged from 220 to 300°C. Both Rheological and mechanical characterization was conducted in order to understand the effect of injection temperature on the properties of crates. Oven aging was also applied for (4 weeks) to evaluate the long-term thermal stability. The results revealed that producing the crates at a temperature range of (260-280 °C) gives the best rheological and mechanical result. The lowest drop in thermal stability has been observed

... Show More
View Publication Preview PDF
Crossref