Pseudomonas aeruginosa has variety of virulence factors that contribute to its pathogenicity. Therefore, rapid detection with high accuracy and specificity is very important in the control of this pathogenic bacterium. To evaluate the accuracy and specificity of Polymerase Chain Reaction (PCR) assay, ETA and gyrB genes were targeted to detect pathogenic strains of P. aeruginosa. Seventy swab samples were taken from patients with infected wounds and burns in two hospitals in Erbil and Koya cities in Iraq. The isolates were traditionally identified using phenotypic methods, and DNA was extracted from the positive samples, to apply PCR using the species specific primers targeting ETA, the gene encoding for exotoxin A, and gyrB gene. The results of this study indicate that 100% of P. aeruginosa isolates harbored the gyrB gene, whereas 74% of these isolates harbored ETA gene. However, the specificity of PCR for detection of P. aeruginosa based on the both genes was 100%, since no amplified product obtained using DNA extracted from other bacterial species. Hence by considering the importance of rapid detection of this bacterium due to the presence of problems in biochemical methods, PCR targeting multiple virulence genes is suggested in identification of pathogenic strains of P. aeruginosa isolated from some infections which should speed diagnosis of an antimicrobial therapy.
15 local isolates of Pseudomonas were obtained from 35 samples from several sources such as soil, water and some high-fat foods. The ability of isolates to produce lipase was measured by the size of the clarification zone formed around the colonies on the lipase production medium and by measuring the enzymatic activity and specific enzymatic activity, the isolate M3 was found to be the most efficient for production of the enzyme, This isolate was identified by microscopic, morphological, some biochemical tests and genetic diagnosis of 16S gene sequences by using the (PCR) technique, and then comparing the results obtained with the National Center for Biotechnology Inform
... Show MoreThe aim of this work was to estimate the concentrations of natural and artificial nuclides in some fertilized and unfertilized plant samples. These samples were collected and prepared in a petri dish for the measurements using gamma spectroscopy. The average values of 238U, 232Th, 40K, and 137Cs for the unfertilized plant samples were (11.964 ± 3.226, 8.273 ± 2.639, 402.436 ± 18.099, and 2.761 ± 1.613) respectively, and for the fertilized plant samples were (30.434 ± 5.282, 22.584 ± 4.620, 711.332 ± 25.806, and 6.986 ± 2.542) respectively. The average values of radiological hazard indices, Raeq, D, D for 137Cs, (AEDE)in, (AEDE)out, Iγ, Hin, and Hout for the unfertilized plant samples were (54.782 ± 7.216, 27.306, 0.469, 0.
... Show MoreA rapid, simple and sensitive spectrophotometric method for the determination of trace amounts of chromium is studied. The method is based on the interaction of chromium with indigo carmine dye in acidic medium and the presence of oxalates as a catalyst for interaction, and after studying the absorption spectrum of the solution resulting observed decrease in the intensity of the absorption. As happened (Bleaching) for color dye, this palace and directly proportional to the chromium (VI) amount was measured intensity of the absorption versus solution was figurehead at a wavelength of 610 nm. A plot of absorbance with chromium (VI) concentration gives a straight line indicating that Beer’s law has been obeyed over the range of 0.5
... Show MoreThe Reversed Phase High Performance Liquid Chromatography (RP-HPLC) has been used for the separation of Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage of the heavy water ,ind
... Show MoreBackground: The majorities of statin-treated patients, in whom low-density lipoprotein cholesterol (LDL-C) targets have been achieved, have had recurrent cardiovascular events (CVE) with an absolute rate remain even higher among patients with disorders of insulin resistance, metabolic syndrome (MetS) and type2 diabetes mellitus (T2DM) as compared to patients devoid of these conditions.Objectives: Provide updated key messages of lipid and lipoprotein abnormalities as indicator for cardiovascular disease (CVD) risk in patients with T2DM and obesity, as well as the current evidence-based treatment targets and interventions to reduce this risk.Key messages: The Residual Risk Reduction Initiative (R3I) emphasized atherogenic dyslipidemia (AD)
... Show MoreThe study included 200 samples were collected from children under two years included (50 samples from each of Cerebrospinal fluid, Blood, Stool and Urine) from, Central Children Hospital and Children's Protections Educational Hospital. Isolates bacterial were obtained cultural, microscopic and biochemical examination and diagnosed to the species by using vitek2 system. The results showed there were contamination in 6.5% of clinical samples. The diagnosed colonies which gave pink color on the MacConkey agar , golden yellow color on the Trypton Soy agar and green color on the Birillent Enterobacter sakazakii agar and gave a probability of 99% in the vit
... Show MoreTwelve samples of cigarettes have been collected from local markets of different types and origins by using (HPGe) detector, and measurement of the specific activity for series U238 and series Th232 in addition to K40 in order to estimate the health risk of cigarettes their by smokers, the results shown that highest specific activity value were be (12. 8±6. 3 Bq/kg, 8. 41±5. 8 Bq/kg, 125. 16±58. 3 Bq/kg), respectively, in the sample (MAC) MacBeth type cigarettes in Brazilian origin, this paper reports data such as (specific activity of K40, series U238, series Th232
In this study, gamma ray transmission method have been used to determine the total porosity in four samples: pure Alumina ( Al2O3 ), Al2O3 + (0.2wt%)MgO , Al2O3 + (0.6wt% )Y2O3 and Al2O3+ (8wt% ) ZrO2 .
The experimental setup for the gamma ray transmission consist of 137Cs gamma source ( 662 KeV ), a NaI (Tl) scintillation detector measured the attenuation of strongly collimated gamma beam through alumina samples.
The porosity obtained by the gamma ray transmission method were compare
... Show MoreEstimations of specific activity concentrations in eight commercial porcelain tiles made in different countries were performed by the use of HPGe detector. We have found that the highest specific activity concentrations for 238U, 40K were equal to (21.120 Bq/kg) and (283.862 Bq/kg) respectively, Iranian origin, while the highest specific activity concentration for 232Th was found to be equal to (29.292 Bq/kg), Iraqi origin; all of which were less than their corresponding recommended values given by (UNSCEAR, 2000). The radiation hazard indices [IÉ£ , Hin ,Hex , Raeq ,DÆ” , (AEDE) in and (AEDE) out] w
... Show MoreThis research describes a straightforward procedure for extracting the pigment of Methylene Blue (MB) dye from aqueous solutions by utilizing a low-cost, safe, natural, and national source. Batch adsorption experiments were carried out to determine contact time, adsorbent dose, and the starting concentration of the adsorbate. For the analysis, a UV spectrophotometer was employed. Dye adsorption equilibrium was obtained after 120 minutes of contact time. Temkin, Langmuir, and Freundlich isotherm adsorption were used at solution concentrations of (3, 4, 6, and 8) mg/l. Adsorption data is used to predict the pseudo first and pseudo second order kinetic equations, Elovich kinetic models, and intra-particle diffusion using pseudo f
... Show More