Atenolol was used with ammonium molybdate to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on reaction between atenolol and ammonium molybdate in an aqueous medium to obtain a dark brown precipitate. Optimum parameters was studied to increase the sensitivity for developed method. A linear range for calibration graph was 0.1-3.5 mmol/L for cell A and 0.3-3.5 mmol/L for cell B, and LOD 133.1680 ng/100 µL and 532.6720 ng/100 µL for cell A and cell B respectively with correlation coefficient (r) 0.9910 for cell A and 0.9901 for cell B, RSD% was lower than 1%, (n=8) for the determination of atenolol at concentration (0.5, 0.7 and 5) mmol/L respectively. The results were compared with classical method UV-Spectrophotometric at λ max=270 nm using the standard addition method via the use of t-test, at 95% confidence level. The comparison of data explain that long distance chasing photometer (NAG-ADF-300-2) is the choice with excellent extended detection and wide application.
The aim of this study is to provide an overview of various models to study drug diffusion for a sustained period into and within the human body. Emphasized the mathematical compartment models using fractional derivative (Caputo model) approach to investigate the change in sustained drug concentration in different compartments of the human body system through the oral route or the intravenous route. Law of mass action, first-order kinetics, and Fick's perfusion principle were used to develop mathematical compartment models representing sustained drug diffusion throughout the human body. To adequately predict the sustained drug diffusion into various compartments of the human body, consider fractional derivative (Caputo model) to investiga
... Show MoreObjectives: The aim of the study was, to assess the nurse's role regarding cardiovascular drug
administration in Erbil city.
Methodology: A descriptive survey was conducted in Hawler teaching and Rizgari teaching Hospitals. The
number of samples is 50 nurses; the period of the study was started from 15th of November 2008 up to
the end of March 2009. A questionnaire was developed by investigators based on extensive review of
available studies and literatures. Data were collected through application of observational check list
consist of two part, part one was demographic sheet and part two about nurse’s responsibility regarding
medication administration which include (before, during, after drug administration). Data
Let A ⊆ V(H) of any graph H, every node w of H be labeled using a set of numbers; , where d(w,v) denotes the distance between node w and the node v in H, known as its open A-distance pattern. A graph H is known as the open distance-pattern uniform (odpu)-graph, if there is a nonempty subset A ⊆V(H) together with is the same for all . Here is known as the open distance pattern uniform (odpu-) labeling of the graph H and A is known as an odpu-set of H. The minimum cardinality of vertices in any odpu-set of H, if it exists, will be known as the odpu-number of the graph H. This article gives a characterization of maximal outerplanar-odpu graphs. Also, it establishes that the possible odpu-number of an odpu-maximal outerplanar graph i
... Show MoreIn this paper, the Mars orbital elements were calculated. These orbital elements—the major axis, the inclination (i), the longitude of the ascending node (W), the argument of the perigee (w), and the eccentricity (e)—are essential to knowing the size and shape of Mars' orbit. The quick basic program was used to calculate the orbital elements and distance of Mars from the Earth from 25/5/1950 over 10000 days. These were calculated using the empirical formula of Meeus, which depended on the Julian date, which slightly changed for 10000 days; Kepler's equation was solved to find Mars' position and its distance from the Sun. The ecliptic and equatorial coordinates of Mars were calculated. The distance between Mars and the center of the E
... Show MoreThe Log-Logistic distribution is one of the important statistical distributions as it can be applied in many fields and biological experiments and other experiments, and its importance comes from the importance of determining the survival function of those experiments. The research will be summarized in making a comparison between the method of maximum likelihood and the method of least squares and the method of weighted least squares to estimate the parameters and survival function of the log-logistic distribution using the comparison criteria MSE, MAPE, IMSE, and this research was applied to real data for breast cancer patients. The results showed that the method of Maximum likelihood best in the case of estimating the paramete
... Show MoreAtenolol is one of beta-adrenergic receptor blocking agent. It is widely used for the treatment of hypertension as a selective antihypertensive drug. But long term usage of atenolol may cause one of the cardiovascular diseases like myocardial infarction. To prove the relationship between atenolol and cardiovascular disease, measurement of creatinekinase-MB as a diagnostic indicator in early and long term usage of this drug by hypertensive patients is recommended. A comparative study was conducted in Al-Yarmouk Teaching Hospital–Emergency Department- on 30 hypertensive patients using atenolol. They were divided into (2) groups A and B according to the duration of the drug usage. Group A- (15) patients with a mean age (56
... Show MoreA newly developed analytical method characterized by its speed and sensitivity for
the determination of cadmium (II) in aqueous solution in three randomly chosen
samples from river water at different locations via turbidimetric measurement by
Ayah 6SX1-T-2D Solar - CFI analyser. The method is based on the formation of
yellowish white precipitate for the complex Cd3[Fe(CN)6]2 by direct reaction of the
cadmium (II) with potassium hexacyano ferrate (III) in aqueous medium. Turbidity
was measured via the reflection of incident light that collides on the surfaces
precipitated particles at 0-180o. Chemical and physical parameters were investigated.
Linear dynamic of cadmium (II) is ranged from 0.05-12 mmol.L-1, with cor
Development of a precise and delicate reaction has been acquired for the determination of vancomycin hydrochloride using batch and cloud point extraction (CPE) methods. The first method is based on the formation of azo dye as a result of diazotized dapsone coupled with vancomycin HCl (VAN) in a basic medium. The sensitivity of this reaction was enhanced by utilizing a nonionic surfactant (Triton X-114) and the cloud point extraction technique (second method). The azo dye formed was extracted into the surfactant-rich phase, dissolved in ethanol and detected at λmax 440 nm spectrophotometrically. The reaction was investigated using both batch and CPE methods (with and without extraction), and a simple comparison between the two
... Show MoreA new, simple and sensitive spectrophotometric method was described for the determination of famotidine (FAM) as a pure material and in pharmaceutical formulation. This method was based on diazotization and coupling reaction between famotidine and diazotized solution of metochlopramide hydrochloride (DMPH) in the presence of phosphate buffer solution to give a compound of azo dye having orange color soluble in water with high absorptivity at a wave length of 478 nm. The data shows that FAM and DMPH combine in the molar ratio of 1:1 at PH 7.0 .The method obeys Beer's law over concentration range of 1-40 ?g.ml-1 of famotidine with a correlation coefficient of 0.9955 and a detection limit of 0.10 ?g.ml-1. The apparent molar absorptivity re
... Show MoreA new simple sensitive and selective spectrophotometric method has been
developed for the analysis of vanadium(V) in three randomly chosen samples from
river water at different locations by continuous flow injection analysis. The method
based on the oxidation of pyrogallol by vanadium(V) in acidic solution to form color
species and the same species was determined using homemade Ayah 6SX1-T-2D
solar cell analyser . Chemical and physical parameters were investigated using the
high intensity of snow white light emitted diode as a source. The linear dynamic
range for the instrument response versus vanadium(V) concentration was 1-200
mg.L-1 with correlation coefficient r = 0.9920. The limit of detection (S/N=3) was 70<