The method of measurement dosimetry in neutron – gamma field by using CaSo4 : Dy (PTFE) disc which has a diameter of 1.3mm and thickness of 0.2mm and using hydrogenated material as a converters of neutron to recoil protons (n-p) reaction, the discs were irradiated by neutron source (241Am-Be) with flux of 4.5?105 n/cm2s for different time to obtain different dose. The TL signals, which we have been obtained by using the converters, are increases to 71%. So we can resolve the neutron and gamma in mixed field.
The study aims at finding out:
1. The students' attitude towards the mixed learning at the university.
2. The statistically significant differences in attitude towards the mixed learning at the university according to the specialization variable.
3. The statistically significant differences in attitude towards the mixed learning at the university according to the gender variable.
The researcher has constructed a scale for measuring the students' attitude towards the mixed learning at the university.
After assuring its validity and reliability, the scale has been given to a sample of (100) students. The sample is selected randomly from (4) colleges of the university of Baghdad, (2) for scientific specialization and (2)for h
Design of experiments (DOE) was made by Minitab software for the study of three factors used in the precipitation process of the Sodium Aluminate solution prepared from digestion of α-Al2O3 to determine the optimum conditions to a produce Boehmite which is used in production of ɤ-Al2O3 during drying and calcination processes, the factors are; the temperature of the sodium aluminate solution, concentration of HCl acid added for the precipitation and the pH of the solution at which the precipitation was ended. The design of the experiments leads to 18 experiments.
The results show that the optimum conditions for the precipitation of the sodium aluminate solution which
... Show MoreThe purpose of this research is to implement the orthogonal polynomials associated with operational matrices to get the approximate solutions for solving two-dimensional elliptic partial differential equations (E-PDEs) with mixed boundary conditions. The orthogonal polynomials are based on the Standard polynomial (
Steady natural and mixed convection flow in a square vented enclosure filled with water-saturated aluminum metal foam is numerically investigated. The left vertical wall is kept at constant temperature and the remaining walls are thermally insulated. Forced convection is imposed by providing an inlet at cavity bottom surface, and a vent at the top surface. Natural convection takes place due to the temperature difference inside the enclosure. Darcy-Brinkman-Forchheimer model for fluid flow and the two-equation of the local thermal non-equilibrium model for heat flow was adopted to describe the flow characteristics within the porous cavity. Numerical results are obtained for a wide range of width of the inlet as a fraction
... Show MoreNew biscarboxylato zwitterionic ligands, namely bis(N-carboxylatoethyl)-4,4 -dipyridinum) L1 and bis(Ncarboxylatopropyl)-)-4,4 -dipyridinum) L2, were synthesized from the reaction of 4,4 -dipyridine with 3-bromopropanoic acid and 4-bromobutanoic acid, respectively. The reaction of these ligands and the azido coligand with some metal ions resulted in the formation of polymeric complexes of general formulae [Cr2(Ln)(N3)4]Cl2·H2O and [M2(Ln)(N3)4] xH2O, where (M = Mn(II), Fe(II), Co(II), Ni(II), Cu(II), Zn(II) and Cd(II); n = 1, 2; x = 1, 1, 1, 1, 0, 1, and 1, respectively.) The oxygens of the carboxylato group are coordinated to the metal ion in a bidentate fashion. The mode of bonding and overall geometry of the complexes were determin
... Show MoreEach Intensity Modulated Radiation Therapy (IMRT) plan needs to be tested and verified before any treatment to check its quality. Octavius 4D-1500 phantom detector is a modern and qualified device for quality assurance procedure. This study aims to compare the common dosimetric criteria 3%/3 mm with 2%/2 mm for H&N plans for the IMRT technique. Twenty-five patients with head and neck (H&N) tumor were with 6MV x-ray photon beam using Monaco 5.1 treatment planning software and exported to Elekta synergy linear accelerator then tested for pretreatment verification study using Octavius 4D-1500 phantom detector. The difference between planned and measured dose were assessed by using local and global gamma index (GI) analysis method at
... Show MoreAnti-tumor necrosis factor treatments for inflammatory bowel disease face challenges like primary nonresponse and secondary loss of response, often due to antidrug antibodies that increase drug clearance. The Fc-gamma receptors type3A (FCGR3A) (rs396991) polymorphism affects infliximab pharmacokinetics and immunogenicity. This study investigates its influence on trough levels, anti-infliximab antibody development, and clinical outcomes in Iraqi ulcerative colitis (UC) patients. This single-center study involved patients on maintenance infliximab therapy who were enrolled. Serum infliximab trough levels and anti-infliximab antibodies (antibodies to infliximab) (free and total) were measured using enzyme-linked immunosorbent assay. Genotyping
... Show MoreIn this research, the problem of multi- objective modal transport was formulated with mixed constraints to find the optimal solution. The foggy approach of the Multi-objective Transfer Model (MOTP) was applied. There are three objectives to reduce costs to the minimum cost of transportation, administrative cost and cost of the goods. The linear membership function, the Exponential membership function, and the Hyperbolic membership function. Where the proposed model was used in the General Company for the manufacture of grain to reduce the cost of transport to the minimum and to find the best plan to transfer the product according to the restrictions imposed on the model.