Preferred Language
Articles
/
bsj-3133
Spectrophotometric and Reverse Flow Injection Method Determination of Nitrazepam in Pharmaceuticals Using O-Coumaric Acid as a New Chromogenic Reagent
...Show More Authors

            A spectrophotometric- reverse flow injection analysis (rFIA) method has been proposed for the   determination of Nitrazepam (NIT) in pure and pharmaceutical preparations. The method is based upon the coupling reaction of NIT with a new reagent O-Coumaric acid (OCA) in the presence of sodium periodate in an aqueous solution. The blue color product was measured at 632 nm. The variation (chemical and physical parameters) related with reverse flow system were estimated. The linearity was over the range 15 - 450 µg/mL of NIT with detection limits and limit of quantification of 3.425 and 11.417 µg mL-1 NIT,respectively. The sample throughput of 28 samples per hour was achieved. Suggested method was successfully applied for the determination of NIT in its dosage forms.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Dec 27 2017
Journal Name
Al-khwarizmi Engineering Journal
A New Structure for Cascaded Single-Stage Distributed Amplifier Using Proposed Active Inductor Loads
...Show More Authors

A modification to cascaded single-stage distributed amplifier (CSSDA) design by using active inductor is proposed. This modification is shown to render the amplifier suitable for high gain operation in small on-chip area. Microwave office program simulation of the Novel design approach shows that it has performance compatible with the conventional distributed amplifiers but with smaller area. The CSSDA is suitable for optical and satellite communication systems.

View Publication Preview PDF
Publication Date
Wed Dec 05 2018
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Spectrophotometric Determination of Chlordiazepoxide in Pharmaceutical Formulations via Oxidative Coupling Reaction with Phenothiazine
...Show More Authors

Abstract

A sensitive, precise and reliable indirect spectrophotometric method for the determination of chlordiazepoxide (CDE) in pure and pharmaceutical dosage forms is described. The method is based on oxidative coupling reaction between amino group resulting from acidic decomposition of CDE with phenothiazine in the presence of sodium periodate to produce an intense green soluble dye that is stable and shows a maximum absorption at 602 nm. The calibration plot indicates that Beer’s law is obeyed over the concentration range of 0.1?50 µg/mL, with a molar absorptivity of 1×104 L/mol cm and correlation coefficient of 0.9994.All the conditions that affecting on the stability and sensitivity of the fo

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Sun Dec 01 2019
Journal Name
Baghdad Science Journal
Studying the Crystal Structure, Topography, and Anti-bacterial of a Novel Titania (TiO2 NPs) Prepared by a Sol-gel Manner
...Show More Authors

In this research, titanium dioxide nanoparticles (TiO2 NPs) were prepared through the sol-gel process at an acidic medium (pH3).TiO2 nanoparticles were prepared from titanium trichloride (TiCl3) as a precursor with Ammonium hydroxide (NH4OH) with 1:3 ratio at 50 °C. The resulting gel was dried at 70 °C to obtain the Nanocrystalline powder. The powder from the drying process was treated thermally at temperatures 500 °C and 700 °C. The crystalline structure, surface morphology, and particle size were studied by using X-ray diffraction (XRD), Atomic Force Microscopy (AFM), and Scanning Electron Microscope (SEM). The results showed (anatase) phase of titanium dioxide with the average grain size

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Jun 04 2017
Journal Name
Baghdad Science Journal
Spectrophotometric determination of Metronidazole and Metronidazole benzoate via first and Second Derivative order spectroscopy
...Show More Authors

A New Spectrophotometric Methods are improved for determination Metronidazole (MTZ) and Metronidazolebenzoate (MTZB) depending on1STand 2nd derivative spectrum of the two drugs by using ethanol as a solvent. Many techniques were proportionated with concentration (peak high to base line, peak to peak and peak area). The linearity of the methodsranged between(1-25µg.ml-1) is obtained. The results were precise and accurate throw RSD% were between (0.041-0.751%) and (0.0331-0.452%), Rec% values between (97.78, 101.87%) and (98.033-102.39%) while the LOD between (0.051-0.231 µg.ml-1) and (0.074-1.04 µg.ml-1) and LOQ between (0.170-0.770µg.ml-1) and (0.074-0.313 µg.ml-1) of (MTZ) and of (MTZB) respectively. These Methods were successfully ap

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Wed Feb 12 2025
Journal Name
Chemchemtech
A REVIEW OF ANALYTICAL METHODS FOR THE ANALYSIS OF PHARMACEUTICALS IN ENVIRONMENTAL SAMPLES
...Show More Authors

One of the main causes for concern is the widespread presence of pharmaceuticals in the environment, which may be harmful to living things. They are often referred to as emerging chemical pollutants in water bodies because they are either still unregulated or undergoing regulation. Pharmaceutical pollution of the environment may have detrimental effects on ecosystem viability, human health, and water quality. In this study, the amount of remaining pharmaceutical compounds in environmental waters was determined using a straightforward review. Pharmaceutical production and consumption have increased due to medical advancements, leading to concerns about their environmental impact and potential harm to living things due to their increa

... Show More
View Publication
Scopus Crossref
Publication Date
Wed Oct 17 2018
Journal Name
Journal Of Economics And Administrative Sciences
New Robust Estimation in Compound Exponential Weibull-Poisson Distribution for both contaminated and non-contaminated Data
...Show More Authors

Abstract

The research Compared two methods for estimating fourparametersof the compound exponential Weibull - Poisson distribution which are the maximum likelihood method and the Downhill Simplex algorithm. Depending on two data cases, the first one assumed the original data (Non-polluting), while the second one assumeddata contamination. Simulation experimentswere conducted for different sample sizes and initial values of parameters and under different levels of contamination. Downhill Simplex algorithm was found to be the best method for in the estimation of the parameters, the probability function and the reliability function of the compound distribution in cases of natural and contaminateddata.

 

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 14 2019
Journal Name
Al-khwarizmi Engineering Journal
Sculptured Surface Design and Implementation by Lofting Design Method Using Cross-sectional B-Spline Curves
...Show More Authors

This research presents a particular designing strategy for a free form of surfaces, constructed by the lofting design method. The regarded surfaces were created by sliding a B-spline curves (profile curves), in addition to describing an automatic procedure for selective identification of sampling points in reverse engineering applications using Coordinate Measurement Machine. Two models have been implemented from (Ureol material) to represent the different cases of B-spline types to clarify its scope of application. The interior data of the desired surfaces was designed by MATLAB software, which then were transformed to UG-NX9 software for connecting the sections that were designed in MATLAB program and obtaining G-code programs for the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Baghdad Science Journal
Determination of Phosphodiesterase Type 5 Enzyme (PDE-5) Inhibitors and Analogues as Adulterants in Selected Herbal Products using Gas Chromatography–Electron Impact-Mass Spectrometer (GC-EI-MS)
...Show More Authors

       Sildenafil, tadalafil, and vardenafil are phosphodiesterase type 5 enzyme (PDE-5) inhibitors used for the treatment of male erectile dysfunction. This present study aims to investigate 55 herbal products indicated for men’s sexual health from the Malaysian market for adulteration of PDE-5 inhibitors and analogues. The screening and identification of 20 PDE-5 inhibitors and analogues in herbal products of various forms (powder, capsules, tablets, and pastels) were conducted using gas chromatography–electron impact-mass spectrometer (GC-EI-MS). The analysis has shown that 19 herbal products were adulterated with PDE-5 inhibitors and analogues. Unique ion fragmentations and the presence of molecular

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Thu Jan 06 2022
Journal Name
Chemical Papers
A solvent collection technique using dispersive liquid–liquid microextraction coupled with spectrophotometry for the trace determination of folic acid in pure, dosage forms and flaxseed
...Show More Authors

A simple, rapid and environmentally friendly dispersive liquid–liquid microextraction method-based spectrophotometric method for the trace determination of folic acid has been developed. The proposed method is based on the formation of a deep yellow product via reaction of folic acid and 1,2-naphthoquine-4-sulfonate at pH = 9. The formed complex was extracted using a mixture of chloroform and ethanol. Then, the tiny organic droplets were measured at λ = 520 nm. At the optimum conditions, linearity was ranged from 0.05 to 1.5 μg/mL for the standard and samples, with a linear correlation coefficient of 0.9996. The detection limits were 0.02, 0.027, 0.03, 0.02 and 0.04 μg/mL for standard, tablet (5 mg), tablet (1 mg), syrup and fl

... Show More
View Publication
Scopus (4)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Dec 20 2021
Journal Name
Baghdad Science Journal
Evaluation Method of Mesh Protocol over ESP32 and ESP8266
...Show More Authors

Internet of Things (IoT) is one of the newest matters in both industry and academia of the communication engineering world. On the other hand, wireless mesh networks, a network topology that has been debate for decades that haven’t been put into use in great scale, can make a transformation when it arises to the network in the IoT world nowadays. A Mesh IoT network is a local network architecture in which linked devices cooperate and route data using a specified protocol. Typically, IoT devices exchange sensor data by connecting to an IoT gateway. However, there are certain limitations if it involves to large number of sensors and the data that should be received is difficult to analyze. The aim of the work here is to implement a self-

... Show More
View Publication Preview PDF
Scopus (15)
Crossref (8)
Scopus Clarivate Crossref