Preferred Language
Articles
/
bsj-2998
Moving Objects Detection Based on Frequency Domain: image processing
...Show More Authors

In this research a proposed technique is used to enhance the frame difference technique performance for extracting moving objects in video file. One of the most effective factors in performance dropping is noise existence, which may cause incorrect moving objects identification. Therefore it was necessary to find a way to diminish this noise effect. Traditional Average and Median spatial filters can be used to handle such situations. But here in this work the focus is on utilizing spectral domain through using Fourier and Wavelet transformations in order to decrease this noise effect. Experiments and statistical features (Entropy, Standard deviation) proved that these transformations can stand to overcome such problems in an elegant way.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jul 10 2024
Journal Name
The Open Neuroimaging Journal
The Efficacy of Bedside Chest Ultrasound in the Detection of Traumatic Pneumothorax
...Show More Authors
Background

Chest X-rays have long been used to diagnose pneumothorax. In trauma patients, chest ultrasonography combined with chest CT may be a safer, faster, and more accurate approach. This could lead to better and quicker management of traumatic pneumothorax, as well as enhanced patient safety and clinical results.

Aim

The purpose of this study was to assess the efficacy and utility of bedside US chest in identifying traumatic pneumothorax and also its capacity to estimate the extent of the lesion in comparison to the gold standard modality chest computed tomography.

... Show More
View Publication
Scopus (6)
Crossref (7)
Scopus Crossref
Publication Date
Wed Feb 03 2016
Journal Name
Nanoscience And Nanotechnology
Fabrication of Functionalize Reduce Graphene Oxide and Its Application in Ampicillin Detection
...Show More Authors

Graphene oxide (GO) was prepared from graphite (GT) with Hammer method, the GO was reduced with hydrazine hydrate to produce a reduced graphene oxide (RGO). The RGO was reacted with thiocarbohydrazide (TCH) to functionalize the RGO with 4-amino-3-symbol-1h-1, 2, 4-triazol-5 (4H) –thion group and to obtain (RGOT). All the prepared nanomaterial and the product of the functionalization RGOT were characterized with Fourier transformer infrared (FT-IR) spectroscopy, X-ray diffraction (XRD) analysis. RGOT mixed with ultrasonic device at different pH values of phosphate buffer solution (PBS), the mixture used to modifying a screen printed carbon electrodes SPCE and with cyclic voltammetry the sensitivity of selectivity of the new modifying elect

... Show More
Preview PDF
Publication Date
Wed Dec 18 2019
Journal Name
Baghdad Science Journal
Detection of Nutrients and Major Ions at Al Muthanna Storage Site Soil
...Show More Authors

In the early 90s military operations and United Nations Special Commission “UNSCOM” teams have been destroyed the past Iraqi chemical program. Both operations led an extensive number of scattered remnants of contaminated areas. The quantities of hazardous materials, incomplete destructed materials, and toxic chemicals were sealed in two bunkers. Deficiency of appropriate destruction technology led to spreading the contamination around the storage site. This paper aims to introduce the environmental detection of the contamination in the storage site area using geospatial analysis technique. The environmental contamination level of nutrients and major ions such as sulphate (SO4), potassium (K), sodium (Na), magnesi

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Mon Apr 19 2010
Journal Name
Computer And Information Science
Quantitative Detection of Left Ventricular Wall Motion Abnormality by Two-Dimensional Echocardiography
...Show More Authors

Echocardiography is a widely used imaging technique to examine various cardiac functions, especially to detect the left ventricular wall motion abnormality. Unfortunately the quality of echocardiograph images and complexities of underlying motion captured, makes it difficult for an in-experienced physicians/ radiologist to describe the motion abnormalities in a crisp way, leading to possible errors in diagnosis. In this study, we present a method to analyze left ventricular wall motion, by using optical flow to estimate velocities of the left ventricular wall segments and find relation between these segments motion. The proposed method will be able to present real clinical help to verify the left ventricular wall motion diagnosis.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jan 18 2022
Journal Name
Photonic Sensors
Arsenic Detection Using Surface Plasmon Resonance Sensor With Hydrous Ferric Oxide Layer
...Show More Authors
Abstract<p>The lethality of inorganic arsenic (As) and the threat it poses have made the development of efficient As detection systems a vital necessity. This research work demonstrates a sensing layer made of hydrous ferric oxide (Fe<sub>2</sub>H<sub>2</sub>O<sub>4</sub>) to detect As(III) and As(V) ions in a surface plasmon resonance system. The sensor conceptualizes on the strength of Fe<sub>2</sub>H<sub>2</sub>O<sub>4</sub> to absorb As ions and the interaction of plasmon resonance towards the changes occurring on the sensing layer. Detection sensitivity values for As(III) and As(V) were 1.083 °·ppb<sup>−1</sup> and 0.922 °·ppb<jats></jats></p> ... Show More
View Publication
Scopus (12)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Mon Feb 18 2019
Journal Name
Iraqi Journal Of Physics
Enhancement of gas response of annealed ZnO film for hydrogen gas detection
...Show More Authors

  The mechanism of hydrogen (H2) gas sensor in the range of 50-200 ppm of RF-sputtered annealed zinc oxide (ZnO) and without annealing was studied. The X-ray Diffraction( XRD) results showed that the Zn metal was completely converted to ZnO with a polycrystalline structure. The I–V characteristics of the device (PT/ZnO/Pt) measured at room temperature before and after annealing at 450 oC for4h, from which a linear relationship has been observed. The sensors had a maximum response to H2 at 350 oC for annealing ZnO and showed stable behavior for detecting H2 gases in the range of 50 to 200 ppm. The annealed film exhibited hig

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Mar 04 2022
Journal Name
Pakistan Journal Of Medical And Health Science
Detection of aadA1 and aac(3)-1V resistance genes in Acinetobacter baumannii
...Show More Authors

Publication Date
Wed Feb 22 2023
Journal Name
Iraqi Journal Of Science
Detection of blaKPC Gene in Some Clinical Klebsiella pneumoniae Isolates in Baghdad
...Show More Authors

For the period from February 2014 till May 2014, one hundred and nine lactose fermenter clinical isolates from different samples (urine, stool, wound swab, blood, and sputum) were collected from Alyarmok, Alkadimiya, and Baghdad teaching hospitals at Baghdad governorate. Identification of all Klebsiella pneumoniae isolates were carried out depending on macroscopic, microscopic characterizations, conventional biochemical tests, and Api 20E system. Fifty-three (48.62%) isolates represented K. pneumoniae; however, 51.73% represented other bacteria. Susceptibility test was achieved to all fifty-three K. pneumoniae isolates using five antibiotic disks (Ceftazidime, Ceftriaxone, Cefotaxime, Imipenem, and Meropenem). Most of tested isolates (90

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2017
Journal Name
Spe
SPE-188966-MS: Drilling problems detection in Basrah oil fields using smartphones
...Show More Authors

Scopus (1)
Scopus
Publication Date
Sun Dec 04 2011
Journal Name
Baghdad Science Journal
Use of cefoxitin as indicator for detection of Methicillin Resistant Staphylococcus aureus
...Show More Authors

Rapid and accurate identification of Methicillin Resistant Staphylococcus aureus is essential in limiting the spread of this bacterium. The aim of study is the detection of Methicillin Resistant Staphylococcus aureus (MRSA) and determining their susceptibility to some antimicrobial agent. A total of fifty clinical Staphylococcus aureus, isolated from the nose of health work staff in surgery unit of Kalar general hospital and from ear of patients attended to the same hospital. The susceptibilities of isolates were determined by the disc diffusion method with oxacillin (1 ?g) and cefoxitin (30 ?g), and by the mannitol salt agar supplemented with cefoxitin (MSA-CFOX), susceptibilities of isolates to other antimicrobial agent were determined b

... Show More
View Publication Preview PDF
Crossref (1)
Crossref