Preferred Language
Articles
/
bsj-2942
Optimization and Validation of RP-HPLC-UV/VIS Method for Determination Some Antioxidants in Dry Calyces of Iraqi Hibiscus Sabdraffia Linn
...Show More Authors

A new (Reversed Phase- High Performance Liquid chromatography) RP-HPLC method with Ultraviolet-Visible spectrophotometry has been optimized and validated for the simultaneous extraction and determination of antioxidants present in Iraqi calyces of Hibiscus Sabdraffia Linn. The method is based on using ultrasonic bath for extracting antioxidants. Limit of detection in μg/ml of Vitamin C, Sabdaretine, Gossypetine, Hibiscetine, Anthocyanins, Dephinidin-3-glucoside were113.8294×10-6,123.0453×10-6,70.3681×10-6,59.6730×10-6,148.1710×10-6,and125.3481×10-6 respectively. The concentration of antioxidants found in dry spacemen of calyces of Iraqi Hibiscus Sabdraffia Linn. under study: Vitamin C, Sabdaretine, Gossypetine, Hibiscetine, Anthocyanins, and Dephinidin-3-glucoside are 258.3 μg/g, 225.51 μg/g, 154.975 μg/g, 111.407 μg/g, 439.442 μg/g, and 185.729 μg/g respectively.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jun 16 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Colorimetric Determination of Salbutamol Sulfate using Spectrophotometry-Continuous Flow Injection Technique in Pure and Pharmaceutical Forms
...Show More Authors

Simple, precise and economic batch and flow injection analysis (FIA)-spectrophotometric methods have been established for simultaneous determination of salbutamol sulfate (SLB) in bulk powder and pharmaceutical forms. Both methods based on diazotization coupling reaction of SLB with another drug compound (sulfadimidine) as a safe and green diazotization agent in alkaline medium. At 444 nm, the maximum absorption of the orange azo-dye product was observed. A thorough investigation of all chemical and physical factors was conducted for batch and FIA procedures to achieve high sensitivity. Under the optimized experimental variables, SLB obeys Beer’s law in the concentration range of 0.25-4 and 10-100 μg/mL with limits of detection of 0.0

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (4)
Scopus Crossref
Publication Date
Mon Mar 01 2010
Journal Name
Journal Of Al-nahrain University
DETERMINATION OF SERUM TRACE ELEMENTSMAGNESIUM, COPPER, ZINC, AND SELENIUM IN ASTHMATIC PATIENTS BY ATOMIC ABSORPTION SPECTROPHOTOMETRY
...Show More Authors

The aim of this study is to evaluate the levels of trace elements Magnesium (Mg), Zinc (Zn), Copper (Cu), and Selenium (Se) in blood sera of asthmatic patients by Atomic Absorption Spectrophotometry (AAS). The concentrations of Mg, Cu, and Zn have been determined by Flame Atomic Absorption spectrophotometry (FAAS), and Se with flameless Graphite Furnace Atomic Absorption Spectrophotometry (GFAAS). The study involves (55) asthmatic patients as study group and (28) subjects as control from both genders. Serum levels of Mg, Cu, and Se were significantly higher (p<0.001 for all) in patients when compared with healthy subjects, while Zn level was relatively significant (p<0.05). Our observations confirm the efficacy and applicability of (AAS) in

... Show More
Preview PDF
Publication Date
Wed Oct 12 2011
Journal Name
Journal Of Liquid Chromatography &amp; Related Technologies
RAPID DETERMINATION OF SPHINGANINE AND SPHINGOSINE IN URINE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY USING MONOLITHIC COLUMN
...Show More Authors

A rapid high performance liquid chromatography method for the determination of sphinganine (Sa) and sphingosine (So) in urine samples by employing a silica-based monolithic column is described. The samples were first extracted using ethyl acetate and derivatized using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol. C20 sphinganine was used as internal standard. Under the optimized conditions, separation was achieved using a mixture of methanol:water (93:7, v/v), column temperature at 30°C, flow rate of 1 mL min−1, and an injection volume of 10 μL. Good linearity was obtained for Sa and So over the concentration range 20–500 ng mL−1(correlation coefficients ≥0.9978). The detection limits were 0.45 ng mL−1 for Sa and

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Thu Oct 01 2020
Journal Name
Biochemical & Cellular Archives
DETERMINATION OF ADVANCED OXIDATIVE PROTEIN PRODUCTS LEVELS AND ITS CORRELATION WITH INFLAMMATION IN DIABETIC FOOT PATIENTS
...Show More Authors

protein oxidation through oxidative stress, which represents the overall status of the protein in the cell/tissue. Due to their increased levels of AOPPs were reported during T2DM. The aim of this study was to assess AOPP level in T2DM subjects with foot ulcer (DFU) and explore its correlation with infection. Type 2 diabetic patients (n=108) and healthy subjects (n=25) were enrolled in this study. The T2DM group was subdivided to diabetic patients without complications (n=25) and eighty-three (83) of them have diabetic foot. They were sub- grouped into two groups according to presence Osteomyelitis and abscess, and in reliance on medical analysis of WBC count and CRP. Group of diabetic without superficial or deep ulcer and no osteomyelitis

... Show More
Scopus (3)
Scopus
Publication Date
Sun Mar 01 2015
Journal Name
Baghdad Science Journal
Spectrophotometric determination of Phenylephrine hydrochloride and Salbutamol sulphate drugs in pharmaceutical preparations using diazotized Metoclopramide hydrochloride
...Show More Authors

A spectrophotometric method has been proposed for the determination of two drugs containing phenol group [phenylephrine hydrochloride (PHP) and salbutamol sulphate (SLB)] in pharmaceutical dosage forms. The method is based on the diazotization reaction of metoclopramide hydrochloride (MCP) and coupling of the diazotized reagent with drugs in alkaline medium to give intense orange colored product (?max at 470 nm for each of PHP and SLB). Variable parameters such as temperature, reaction time and concentration of the reactants have been analyzed and optimized. Under the proposed optimum condition, Beer’s law was obeyed in the concentration range of 1-32 and 1-14 ?g mL-1 for PHP and SLB, respectively. The limit of detection (LOD) and l

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Dec 25 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Quantitative Determination and Cytotoxic Effect of Oleanolic Acid from Olea europaea Leaves Extract Cultivated in Iraq
...Show More Authors

Since its first description as a cytotoxic agent, Olea europaea leaves extract gained significant popularity against human breast cancer, ethyl acetate extract of Olea europaea leaves obtained by acid hydrolysis method was evaluated in vitro as cytotoxic agent against new human breast cancer (AMJ13) cell line, using the MTT assay. One main pentacyclic triterpenoid; oleanolic acid, was isolated from leaves of Olea europaea by well-known two different methods, but not used for this compound before, the acidic hydrolysis method and basic acidic method. The presence of oleanolic acid was proved in both methods with qualitative and quantitative d

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (1)
Scopus Crossref
Publication Date
Mon Aug 04 2014
Journal Name
Iraqi National Journal Of Chemistry
Comparative Study for Antibacterial Activity of Some Maleamic acid Derivatives with Some Commercial Antibiotic
...Show More Authors

Publication Date
Tue Jan 11 2022
Journal Name
3rd International Scientific Conference Of Alkafeel University (iscku 2021)
Elimination of the broadening in X-ray diffraction lines profile for nanoparticles by using the analysis of diffraction lines method
...Show More Authors

In this research, the results of the Integral breadth method were used to analyze the X-ray lines to determine the crystallite size and lattice strain of the zirconium oxide nanoparticles and the value of the crystal size was equal to (8.2nm) and the lattice strain (0.001955), and then the results were compared with three other methods, which are the Scherer and Scherer dynamical diffraction theory and two formulas of the Scherer and Wilson method.the results were as followsScherer crystallite size(7.4nm)and lattice strain(0.011968),Schererdynamic method crystallite size(7.5 nm),Scherrer and Wilson methodcrystallite size( 8.5nm) and lattice strain( 0.001919).And using another formula for Schearer and Wilson methodwe obtain the size of the c

... Show More
View Publication
Scopus (4)
Crossref (3)
Scopus Crossref
Publication Date
Sat Mar 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Study on Kinetic and Optimization of Continuous Advanced Oxidative Decolorization of Brilliant Reactive Red Dye
...Show More Authors

The azo dye brilliant reactive red K-2BP (λmax = 534 nm) is widely used for coloring textiles because of its low-cost and tolerance fastness properties. Wastewaters treatment that contains the dye by conventional ways is usually inadequate due to its resistance to biological and chemical degradation. During this study, the continuous reactor of an advanced oxidation method supported the use of H2O2/sunlight, H2O2/UV, H2O2/TiO2/sunlight, and H2O2/TiO2/UV for decolorization of brilliant reactive red dye from the effluent. The existence of an optimum pH, H2O2 concentration, TiO2 concentration, and d

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Wed Jul 01 2020
Journal Name
Journal Of Engineering
Utilizing Load and Loss Factors in Determination of the Technical Power Losses in Distribution System’s Feeders: Case Study
...Show More Authors

This study uses load factor and loss factor to determine the power losses of the electrical feeders. An approach is presented to calculate the power losses in the distribution system. The feeder’s technical data and daily operation recorded data are used to calculate and analyze power losses.

This paper presents more realistic method for calculating the power losses based on load and loss factors instead of the traditional methods of calculating the power losses that uses the RMS value of the load current which not consider the load varying with respect to the time. Eight 11kV feeders are taken as a case study for our work to calculate load factor, loss factor and power losses. Four of them (F40, F42, F43 and F

... Show More
View Publication Preview PDF
Crossref