Preferred Language
Articles
/
bsj-2937
Electronic Structure of Copper Antimony Using Compton Scattering Technique
...Show More Authors

In this paper we present the first ever measured experimental electron momentum density of Cu2Sb at an intermediate resolution (0.6 a.u.) using 59.54 keV 241Am Compton spectrometer. The measurements are compared with the theoretical Compton profiles using density function theory (DFT) within a linear combination of an atomic orbitals (LCAO) method. In DFT calculation, Perdew-Burke-Ernzerhof (PBE) scheme is employed to treat correlation whereas exchange is included by following the Becke scheme. It is seen that various approximations within LCAO-DFT show relatively better agreement with the experimental Compton data. Ionic model calculations for a number of configurations (Cu+x/2)2(Sb-x) (0.0≤x≤2.0) are also performed utilizing free atom profiles, the ionic model suggests transfer of 2.0 electrons per Cu atom from 4s state to 5p state of Sb.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Nov 15 2025
Journal Name
Baghdad Science Journal
Studying the Corrosion Inhibition Ability of Metoclopramide Drug on the Copper Surface in Seawater and Theoretical Studies
...Show More Authors

Protection study of the corrosion behavior of Copper surface was conducted with several concentrations of drug. Experimentally, voltammetric measurements were used to check the inhibition efficiency (% IE) in saline solution of 3.5% NaCl. The results showed an increase in the inhibition efficiency with increasing the concentration of the drug was 95.90%. Theoretical treatment of the drug in the gas phase was performed using the (hyperchem-8.07) program for molecular mechanics and semi-empirical computations. The (PM3) approach was used to determine the heat of formation (1H˚f), binding energy (1Eb), and total energy (ET

View Publication
Crossref (2)
Scopus Crossref
Publication Date
Sat Oct 19 2024
Journal Name
Baghdad Science Journal
Synthesis, Characterization and Biological Activity of New Ligand     Derived from 4-‎(Dimethylamino) Benzaldehyde and Nano Copper Complex
...Show More Authors

الصيغة العامة للمعقدات الجديدة [M2(BDS)Cl4] الناتجة من تفاعل الليكاند الجديد] ن1,ن4-ثنائي(1أ –بنزو]د[ اميدازول-2-يل)-ن1,ن4-ثنائي(4-ثنائي مثيل امينو) بنزيل) سكسنمايد[ (BDS) مع الايونات الفلزية الكادميوم, الكوبلت, الزئبق, النحاس والنيكل. تم اشتقاق هذا الليكاند من تفاعل المواد الثلاث 4-(ثنائي ميثيل أمينو) بنزالدهيد، 2-أمينو بنزيميدازول، وكلوريد السكسينيل. تم تشخيص المركبات باستخدام مطيافية طيف الاشعة تحت الحمراء وطيف الرن

... Show More
View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Wed Mar 19 2008
Journal Name
Ibn Al-haitham Journal For Pure And Applied Science
Synthesis and Characterisation of Novel Cobalt (li), Copper (II) and Mercury (II) Complexes of Poly Vinyl Urethanised Oxime
...Show More Authors

The reaction of poly (vinyl alcohol) (PV A) with Urea in (DMSO) resulted in uerthanised oxim, wr,ich reacted with diacetylmonoxime in a (DY.ISOfmethanol) to give anew type (N2) polymeric bidentate imine oxime ligand [HL], The ligand was reacted with MCh (where M= Co, Cu, and Hg). Under reflux in a (DMF/Methanol) mixture with (I:1) ratio to give Complexes of the general formula [M (T.)2]X, (where M= Co,Hg, Cu). All .:ompouncs have been characterized by spectroscopic methods [IR, U.V.-Vis, A tomi<;absorption] microanalysis along with conductivity measurements, from the above:: data the proposed molecular structure for Co,Cu, and Hg is a distorted. Tetrahedml

Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Analytical Potentiality of Computer - Controlled Background Correction with Electrothermal Atomic Emission Spectrometry : Determination of Copper in Milk Powder
...Show More Authors

A fully automatic electrothermal atomic emission spectrometry (ETA-AES) is described. This system is based on an echelle monochromator modified for wave¬length modulation which is completely controlled by microcomputer . The advantages of the system in atomic spectrometry have been discussed . Aspects of the analytical performances such as calibration ? dection limit, precision , and recovery for copper are considered . This system is applied for routine determination of copper in commercial powdered mill? by slurr>' atomization versus aqueous atomization techniques.

View Publication Preview PDF
Publication Date
Sat Oct 14 2017
Journal Name
European Chemical Bulletin
SYNTHESIS, SPECTROSCOPIC AND ANTIBACTERIAL STUDY OF ZINC, COPPER AND NICKEL COMPLEXES WITH NEW DERIVATIVE OF L-ASCORBIC ACID
...Show More Authors

View Publication
Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Journal Of Engineering
Removal of Copper from Simulated Wastewater by Applying Electromagnetic Adsorption for Locally Prepared Activated Carbon of Banana Peels
...Show More Authors

The adsorption of copper ions onto produced activated carbon from banana peels (with particle size 250 µm) in a single component system with applying magnetic field has been studied using fixed bed adsorber. The fixed bed breakthrough curves for the copper ions were investigated. The adsorption capacity for Cu (II) was investigated. It was found that 1) the exposure distance (E.D) and strength of magnetic field (B), affected the degree of adsorption; and 2) experiments showed that removal of Cu ions and accumulative adsorption capacity of adsorbent increase as the exposure distance and strength of magnetic field increase.
 

View Publication Preview PDF
Publication Date
Mon Mar 11 2019
Journal Name
Baghdad Science Journal
Effects of Discharge Current and Target Thickness in Dc-Magnetron Sputtering on Grain Size of Copper Deposited Samples
...Show More Authors

A study of the effects of the discharge (sputtering) currents (60-75 mA) and the thickness of copper target (0.037, 0.055 and 0.085 mm) on the prepared samples was performed. These samples were deposited with pure copper on a glass substrate using dc magnetron sputtering with a magnetic flux density of 150 gauss at the center. The effects of these two parameters were studied on the height, diameter, and size of the deposition copper grains as well as the roughness of surface samples using atomic force microscopy (AFM).The results of this study showed that it is possible to control the specifications of copper grains by changing the discharge currents and the thickness of the target material. The increase in discharge curre

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Mon Dec 02 2013
Journal Name
Al-nahrain Journal Of Science
Effect of Magnetized Water on Histological Structure of Heart, Lung and Spleen of Albino Rats
...Show More Authors

The aim of the study was to investigate the effect of magnetized water on the histological structure of heart, lung and spleen. For this purpose, twenty five albino rats were divided into five equal groups, the first group was considered as control group. The other groups were given magnetized water with intensity of 250, 750, 1000, 1500 gause every day for 30 days. Then the animals were sacrificed and the histological change on heart, lung and spleen was studied. Histopathology of heart in rats treated with magnetic water with intensity of 250, 750, 1000, 1500 gause showed no clear pathological lesion. Lung section of rats treated with 250 gause of magnetic water showed no pathological lesion, while lung section belongs to rats group given

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Thu Dec 03 2015
Journal Name
Al- Kindy College Medical Journal
Proximal palmar mini-incision carpal tunnel release technique
...Show More Authors

Background: Carpal tunnel syndrome is the most common entrapment neuropathy in humans today. For patients in whom conservative treatment fails, surgical decompression is indicated. Various surgical techniques are becoming increasingly popular. Due to the rapid postoperative recovery shown after endoscopic operations, proximal palmar mini-incision for carpal tunnel release is a comparative alternative. Methods: Ninety four patients [113 hands] with a carpal tunnel syndrome underwent carpal tunnel release through a 1-cm longitudinal incision made just over the distal flexor crease. The self- administered Boston Questionnaire was used to assess the severity of patients’ symptoms and their functional status, both before and after the surgical

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 30 2015
Journal Name
Al-kindy College Medical Journal
Proximal palmar mini-incision carpal tunnel release technique
...Show More Authors

Background: Carpal tunnel syndrome is the most common entrapment neuropathy in humans today. For patients in whom conservative treatment fails, surgical decompression is indicated. Various surgical techniques are becoming increasingly popular. Due to the rapid postoperative recovery shown after endoscopic operations, proximal palmar mini-incision for carpal tunnel release is a comparative alternative.Methods: Ninety four patients [113 hands] with a carpal tunnel syndrome underwent carpal tunnel release through a 1-cm longitudinal incision made just over the distal flexor crease. The self- administered Boston Questionnaire was used to assess the severity of patients’ symptoms and their functional status, both before and after the surgic

... Show More
View Publication Preview PDF