Background: In advanced diabetes mellitus, serum levels of the most hormones are altered due to several interplaying mechanisms. Objective: To assess the relation of serum leptin and lipid profile in type 2 diabetic nephropathy. Patients and Method: Serum leptin levels and its relation to lipid profile were estimated in 62 patients with type 2 diabetic nephropathy attending the National Diabetes Center in Al- Mustansiriya University, and (26) healthy individuals considered as control group. The diabetic patients were classified into three groups, (24) pathients with normoalbuminuria (21) patients with microalbuminuria and (17) patients with macroalbuminuria. Fasting plasma glucose, serum creatinine, Hb A1c %, lipid profile (Total cholesterol, LDL- Cholesterol, HDL- Cholesterol and Triglyceride) and urinary albumin, were measured to establish the possibility of using these biomarkers as a supplementary to serum leptin to be a diagnostic test for type 2 diabetic nephropathy. Results: Serum leptin levels showed a significant elevation in microalbuminuria (20.08± 4.50 ng/ml) and macroalbuminuria groups (22.35± 6.89 ng/ml) as compared to nondiabetic normal control group (10.64 ± 3.17 ng/ml). There was no significant differences observed in serum leptin levels between the normoalbuminuria group (13.96 ± 5.73 ng/ml) and healthy controls, but a significant positive differences were noticed in the levels of fasting plasma glucose, serum creatinine, Hb A1c% and lipid profile in the three patient groups in comparison with the control group. While no significant correlation was observed between these biomarkers levels and serum leptin values. Conclusion: It might be concluded that serum leptin levels were elevated in type 2 diabetic patients with microalbuminuria and macroalbuminuria, suggesting that renal leptin degradation is impaired in early stage of kidney damage and this impairment increase with the progression of this disease. Leptin hormone may consider according to these results as a risk factor for progression of kidney disease in diabetic patients.
In this publication, several six coordinate bridged-polymeric metal complexes are reported. The reaction of 4,4`-dipyridine with ethyl chloroacetate in mole ratio of 1:2 gave the multidentate carboxylate ligand bis(N-carboxylatomethyl)-4,4`-dipyridinium). The reaction of the ligand with metal chloride and sodium azide resulted in the formation of the required polymeric complexes. Upon complex formation, the carboxylato ligand behaves as a neutral multidantate species. The mode of bonding and overall geometry of the complexes were determined through physicochemical and spectroscopic methods. These studies revealed octahedral geometry about metal centres and complexes of the general formula [Cr2(L)(N3)4]Cl2.H2O, Na2[Ag2(L)(N3)4].H2O and [M2(L
... Show MoreIn this work, porous silicon (PS) are fabricated using electrochemical etching (ECE) process for p-type crystalline silicon (c-Si) wafers of (100) orientation. The structural, morphological and electrical properties of PS synthesized at etching current density of (10, 20, 30) mA/cm2 at constant etching time 10 min are studied. From X-ray diffraction (XRD) measurement, the value of FWHM is in general decreases with increasing current density for p-type porous silicon (p-PS). Atomic force microscope (AFM) showed that for p-PS the average pore diameter decreases at 20 mA. Porous silicon which formed on silicon will be a junction so I-V characteristics have been studied in the dark to calculate ideality factor (n), and saturation current (Is
... Show MoreIn this paper, the process for finding an approximate solution of nonlinear three-dimensional (3D) Volterra type integral operator equation (N3D-VIOE) in R3 is introduced. The modelling of the majorant function (MF) with the modified Newton method (MNM) is employed to convert N3D-VIOE to the linear 3D Volterra type integral operator equation (L3D-VIOE). The method of trapezoidal rule (TR) and collocation points are utilized to determine the approximate solution of L3D-VIOE by dealing with the linear form of the algebraic system. The existence of the approximate solution and its uniqueness are proved, and illustrative examples are provided to show the accuracy and efficiency of the model.
Mathematical Subject Classificat
... Show MoreIn this study, we introduce new a nanocomposite of functionalize graphene oxide FGO and functionalize multi wall carbon nanotube (F-MWCNT-FGO).The formation of nanocomposite was confirmed by FT-IR ,XRD and SEM. The magnitude of the dielectric permittivity of the (F-MWCNT-FGO) nanocomposite appears to be very high in the low frequency range and show a unique negative permittivity at frequencies range from 400 Hz to 4000Hz. The ac conductivity of nanocomposite reaches 23.8 S.m-1 at 100Hz.
The imbalances and economic problems which it face the countries, it is a result of international economic developments or changes or global crises such as deterioration in trade, sharp changes in oil prices, increasing global indebtedness, sharp changes in foreign exchange rates and other changes, all that, they affect the economic features of any country. and These influences vary from one country to another according to the rigidity of its economy and its potential in maneuvering with economic plans and actions that would reduce the impact or avoidance with minimal damage. Therefore, the countries that suffer from accumulated economic problems as a result of mismanagement and poor planning or suffe
... Show MoreZinc oxide nanoparticles sample is prepared by the precipitation method. This method involves using zinc nitrate and urea in aqueous solution, then (AgNO3) Solution with different concentrations is added. The obtained precipitated compound is structurally characterized by X-ray diffraction (XRD), Scanning electron microscopy (SEM), Atomic force microscopy (AFM) and Fourier transform infrared spectroscopy (FTIR). The average particle size of nanoparticles is around 28nm in pure, the average particle size reaches 26nm with adding AgNO3 (0.05g in100ml =0.002 M) (0.1g in100ml=0.0058M), AgNO3 (0.2g in 100ml=0.01M) was 25nm. The FTIR result shows the existence of -CO, -CO2, -OH, and -NO2- groups in sample and oxides (ZnO, Ag2O).and used an
... Show MoreBackground: Knee osteoarthritis (KOA) is a common joint disorder leading to considerable pain and locomotor disability in lower limb function. Locomotor disability, which is difficulty in activities of daily living related to lower limb function, can be the consequence of KOA, so early diagnosis and management may improve quality of life.
Objective: To assess the contribution of radiological osteoarthritis of the knees to disability in the activities of daily living related to lower limb function.
Methods: One hundred twenty Iraqi KOA patients (104 females and 16 males) who were attending to Rheumatology Unit, Full history was taken and complete clinical exami
... Show More