A simple, cheap, fast, accurate, Safety and sensitive spectrophotometric method for the determination of sulfamethaxazole (SFMx), in pure form and pharmaceutical dosage forms. has been described The Method is based on the diazotization of the drug by sodium nitrite in acidic medium at 5Cº followed by coupling with salbutamol sulphate (SBS) drug to form orange color the product was stabilized and measured at 452 nm Beer’s law is obeyed in the concentration range of 2.5-87.5 ?g ml-1 with molar absorptivity of 2.5x104 L mole-1 cm-1. All variables including the reagent concentration, reaction time, color stability period, and sulfamethaxazole /salbutamol ratio were studied in order to optimize the reaction conditions. No interferences were observed Results of analysis were validated statistically and by recovery studies. These methods are successfully employed for the determination of sulfamethaxazole in some pharmaceutical preparations.. The developed method is easy to use and accurate for routine studies relative to HPLC and other techniques.
Dora petroleum refinery waste water is the one of the important source of pollution by priority pollutant aromatic compound discharged to Tigris river in Iraq. the station has waste water treatment unit contains many treatment subunits The most important sub units is :skimmer units ,physiochemical unit ,daf unit, biological unit. The aim of research project is to study the ability of unit to remove the priority pollutant aromatic compound and follow up these compounds in river to study ability of river to self removal. A solid phase extraction (SPE) followed by high performance liquid chromatography-ultra violet (HPLC-UV) technique is depicted for the quantitative estimation of benzidines and phenols. Experimental studies were performed to
... Show MoreA simple, accurate and rapid method for separation and determination of most commonly usedinsecticides in Iraq [thiamethoxam (Thi), imidacloprid (Imi), indoxacarb (Ind), and abamectin (Aba)] ispresented. The separation was performed by gradient reversed-phase high performance liquidchromatography on a C18 stationary phase column. The method was developed and validated. The-1mobile phase was a mixture of acetonitrile and water using gradient flow. The flow rate was 1.0 mL min .The optimum temperature of separation was 25 ºC. The detection was performed at multiple wavelengths.The analysis time was up to 10.5 minutes with retention times of 3.221, 3.854, 6.385, and 9.452 min for-1the studied insecticides. The linearity was in the range of 0.
... Show MoreThe present work establishes and validates HILIC strategies simple, accurate, exact and precise in pure form and inpharmaceutical dosage for separating and determining theophylline. These methods are developed on HILIC theophyllineseparation in columns ZIC2 and ZIC3. The eluent was prepared by mixing buffer (20% sodium acetate-40 mM, pH 5.5), 80%acetonitrile. The flow rate is 0.8 mL/min, with gradient elution and UV detection at 270 nm. In the ZIC2 and ZIC3 columns oftheophylline determining, the concentration range was 0.01-4μg.ml-1. The lower limit of detection and quantification fortheophylline were determined as 0.130, 0.190 μg.ml-1 and accuracy were 99.70%, 99.58% on ZIC2 and ZIC3, respectively. TheHILIC methods developed and validat
... Show MoreZinc is one of the essential trace elements, it plays a key role in many biochemical and functional processes. It is less harmful than many other minerals, in the case of exposure to high doses of zinc, poisoning occurs, and this poisoning may mostly result from the accidental ingestion of household products containing zinc or nutritional supplements, this study was conducted to find out the effects of zinc on the concentration of amino acid. A total of 30 adult white mouse males were taken and divided into three groups; the first group (control) of 10 mice taken with distilled water for 30 days, the second group includes 10 mice that were dose with Zn drug concentration of 50 mg/kg/day for 30 days, the third group includes 10 mice that wer
... Show MorePotentiostatic polarization and weight loss methods have been used to investigate the corrosion behavior of carbon steel in sodium chloride solution at different concentrations (0.1, 0.4 and 0.6) M under the influence of temperatures ( 293, 298, 303, 308 and 313) K. The inhibition efficiency of the amoxicillin drug on carbon steel in 0.6 M NaCl has also been studied based on concentration and temperature. The corrosion rate showed that all salt concentrations ( NaCl solution) resulted in corrosion of carbon steel in varying ratio and 0.6 M of salt solution was the highest rate (50.46 g/m².d). The results also indicate that the rate of corrosion increases at a temperature of 313 K.. Potentiodynamic polarization studi
... Show MoreOcular drug delivery is challenging due to the presence of anatomical and physiological barriers. These barriers can affect drug entry into the eye following multiple routes of administration (e.g., topical, systemic, and injectable). Topical administration in the form of eye drops is preferred for treating anterior segment diseases, as it is convenient and provides local delivery of drugs. Major concerns with topical delivery include poor drug absorption and low bioavailability. To improve the bioavailability of topically administered drugs, novel drug delivery systems are being investigated. Nanocarrier delivery systems demonstrate enhanced drug permeation and prolonged drug release. This review provides an overview of ocular barr
... Show MoreThe aim of this study was intended to study the effect of rifadin drug on lipids metabolism in the blood of the rabbits .Eight rabbits were used in the experiment ,they were divided into two groups ,first group(control group ) was administrated with 15mg/ml /day normal saline for 35 days ,while the second group (treated group )was administrated with (15/mg /kg/day) for 35 days of rifadin( capsule 300mg/kg).This study examined the influences of rifadin drug on the concentration of cholesterol , triglycerides , HDL ,LDL and VLDL in rabbits sera .The result showed that there were no significant increased (p>0.05) in cholesterol concentration in rifadin treated group compared with control group ,and th
... Show MoreIn this work, ZnO quantum dots (Q.dots) and nanorods were prepared. ZnO quantum dots were prepared by self-assembly method of zinc acetate solution with KOH solution, while ZnO nanorods were prepared by hydrothermal method of zinc nitrate hexahydrate Zn (NO3)2.6H2O with hexamethy lenetetramin (HMT) C6H12N4. The optical , structural and spectroscopic properties of the product quantum dot were studied. The results show the dependence of the optical properties on the crystal dimension and the formation of the trap states in the energy band gap. The deep levels emission was studied for n-ZnO and p-ZnO. The preparation ZnO nanorods show semiconductor behavior of p-type, which is a difficult process by doping because native defects.
Background: Inflammatory bowel disease (IBD) is a collection of chronic, recurrent inflammatory illnesses of the gastrointestinal system, including Crohn's disease (CD). Infliximab is one of the biological medications used to treat CD. Therapeutic drug monitoring has evolved as a treatment in IBD, aiming to optimize benefit while meeting more demanding, objective end criteria. Objective: To determine the achievement of target trough level (TL), develop anti-drug antibodies (ADAs) to infliximab, assess response to therapy, and study TL relations with different variables. Methods: The present study was cross-sectional and conducted from May 2022 to November 2022. It included 40 CD patients allotted into 2 groups: group 1 patients ach
... Show MoreThe health care industry is witnessing an increasing trend in the use of generic medicines because of their presumed low cost compared with innovator medicines. The aim of this study was to determine and compare the performance of the copy drug Osveral®and its innovator drug deferasirox (Exjade®).
A prospective observational study including 223 patients receiving the branded medicine Exjade®and 101 patients receiving the copy Osveral®was carried out. Data were assessed for a 1-year period and included clinical symptoms, serum ferrit