Preferred Language
Articles
/
bsj-2903
Comparative Bioequivalence Studies of doxysam and doxycycline (Pfizer) by reversed phase HPLC.
...Show More Authors

Isocratic high performance liquid chromatography on reversed phase a (150x 4.6 mm I.D), 5 ?m ?-Bondapak RP-8 column (with acidic mobile phase allow the separation of doxcycycline hydrochloride with low detection limit of 0.2 µg/ml detected by UV set at 226 nm. The method was validated for Doxycycline between 0.156- to 5 µg/ml. The concentration of doxycycline was assessed in two single dose randomized crossover studies with intervals of one week between two period. In sera of 20 adults healthy male volunteers with average age of (42 + 10) year, body weight 48-85 kg, body height of (160-185cm) after a single dose of doxycycline hydrochoride 100 mg in form of capsules were orally administrated for both formulations. The blood samples (2ml) were drawn concomitantly from 0.5 – 24 hours. µg The pharmacokinetics parameter were obtained from the mean serum concentration measured at various sampling times for both formulations. The maximum peak concentration (Cmax) of doxycycline reference drug from Pfizer In serum was (3.1 +0.094 µg /ml) attained in 2 hrs. While the maximum concentration (Cmax) of test drug doxysam (2.8 +0.098 µg /ml) attained in about 2 hrs, both drug have long elimination time with half time of approximately (13 hrs.) Both test and reference drug were show no significant difference in pharmacokinetics parameters, so they were considered to be bioequivalent.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Sep 24 2021
Journal Name
Indonesian Journal Of Chemistry
Molecular Imprinted of Nylon 6 for Selective Separation of Procaine by Solid-Phase Extraction
...Show More Authors

The study is based on the selective binding ability of the drug compound procaine (PRO) on a surface imprinted with nylon 6 (N6) polymer. Physical characterization of the polymer template was performed by X-ray diffraction and DSC thermal analysis. The imprinted polymer showed a high adsorption capacity to trap procaine (237 µg/g) and excellent recognition ability with an imprinted factor equal to 3.2. The method was applied to an extraction column simulating a solid-phase extraction to separate the drug compound in the presence of tinoxicam and nucleosimide separately and in a mixture of them with a recovery rate more than the presence of tinoxicam and nucleosimide separately and in a mixture of them with a recovery rate of more t

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Jun 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Corrosion Inhibition of Carbon Steel under Two Phase Flow (Water-Petroleum) Simulated by Turbulently Agitated System
...Show More Authors

The corrosion of carbon steel in single phase (water with 0.1N NaCl ) and two immiscible phases (kerosene-water) using turbulently agitated system is investigated. The experiments are carried out for Reynolds number (Re) range of 38000 to 95000 corresponding  to rotational velocities from 600 to 1400 rpm using circular disk turbine agitator at 40 0C. In two-phase system test runs are carried out in aqueous phase (water) concentrations of 1 % vol., 5 % vol., 8% vol., and 16% vol. mixed with kerosene at various Re. The effect of Reynolds number (Re), percent of dispersed phase, dispersed drops diameter, and number of drops per unit volume on the corrosion rate is investigated and discussed. Test runs are carried out using two types of

... Show More
View Publication Preview PDF
Publication Date
Sat May 01 2021
Journal Name
Journal Of Physics: Conference Series
Adsorption Studies of Cobalt (II) Complex By Bentonite clay surface
...Show More Authors

This paper is summarized with one of the applications of adsorption behavior; A UV-Vis method has been applied to survey the isotherm of adsorption. Results for experimental showed the applicability of Langmuir equation. The effect of temperature on the adsorption of cobalt (II) Complex by bentonite surface was studied. The results shown that the amount of adsorption was formed to increase, such as the temperature increase (Endothermic process). Cobalt (II) Complex has adsorption studies by bentonite surface at different pH values (1.6-10); these studies displayed an increase in adsorption with increasing pH. ∆G, ∆H, and ∆S thermodynamic functions of the cobalt (II) Complex for their adsorption have been calculated

Publication Date
Mon May 31 2021
Journal Name
Journal Of Physics: Conference Series
Adsorption Studies of Cobalt (II) Complex By Bentonite clay surface
...Show More Authors

This paper is summarized with one of the applications of adsorption behavior; A UV-Vis method has been applied to survey the isotherm of adsorption. Results for experimental showed the applicability of Langmuir equation. The effect of temperature on the adsorption of cobalt (II) Complex by bentonite surface was studied. The results shown that the amount of adsorption was formed to increase, such as the temperature increase (Endothermic process). Cobalt (II) Complex has adsorption studies by bentonite surface at different pH values (1.6-10); these studies displayed an increase in adsorption with increasing pH. ΔG, ΔH, and ΔS thermodynamic functions of the cobalt (II) Complex for their adsorption have been calculated.

Scopus (4)
Crossref (5)
Scopus Crossref
Publication Date
Wed Dec 30 2009
Journal Name
Iraqi Journal Of Physics
Synthesis of Nanosilica Glass Activated by Erbium Ions, Spectroscopic studies
...Show More Authors

Erbium, as optical probe, doped silicate sol-gel glass with
different Er concentrations was formed by wet chemical synthesis
method using ethanol, water and tetraethaylorthosilicate
[Si(OC2H5)4] precursor. Erbium ions were incorporated into silica
sol-gel matrix via dissolution of Erbium chloride solution into the
initial Si(OC2H5)4 precursor sol. Aluminum (Al) as a co-dopant was
added to the final precursor in the form of Aluminum chloride
(AlCl3) solution. The prepared samples were analyzed using atomic
absorption analysis, X-ray diffraction and spectroscopic tests. The
experimental results concerned with the transmission spectra suggest
that the final samples have a good transparency and homogeneity.
A

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 05 2023
Journal Name
Al-khwarizmi Engineering Journal
Extraction of Bovine Serum Albumin by Aqueous Two-Phase System Using PEG4000/Sodium Citrate and PEG8000/Sodium Phosphate
...Show More Authors

Aqueous Two Phase System (ATPS) or liquid-liquid extraction is used in biotechnology to recover valuable compounds from raw sources. In Aqueous Two-Phase Systems, many factors influence the Partition coefficient, K, (which is the ratio of protein concentration in the top phase to that in the bottom phase) and the Recovery percentage (Rec%). In this research, two systems of ATPS were used: first, polyethylene glycol (PEG) 4000/Sodium citrate (SC), and the second, PEG8000/ Sodium phosphate (SPH), for the extraction of Bovine Serum Albumin (BSA). The behavior of Rec% and K of pure (BSA) in ATPS has been investigated throughout the study by the effects of five parameters: temperature, concentration of polyethylene glycol (P

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (4)
Scopus Crossref
Publication Date
Sun Nov 01 2015
Journal Name
Journal Of Engineering
BatchHeavy MetalsBiosorption by Punica granatum Peels: Equilibrium andKinetic Studies
...Show More Authors

This research was conducted to study the feasibility of using fruit peels as biosorbent for removal of Pb+2, Cu+2 and Zn+2 ions from simulated wastewater. A waste biomass of Pomegranate Peel or Punicagranatum L. (P. granatum L.) was chosen as neutral biosorbent in this study.Fourier transformation infrared (FTIR) was used to characterize the surface of PGP, the results confirm that amino, carboxylic, hydroxyl and carbonyl group on the surface of PGP. Different parameters such as initial concentration range between (25-200) mg/L, pH (3-7), contact time (1-2) hour, amount of sorbent (0.1- 4) gm, agitation speed range (200- 500) rpm and temperature (25- 50oC), influencing the sorp

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 11 2018
Journal Name
Iraqi Journal Of Physics
Spectroscopic and structural studies of cadmium oxide thin films prepared by D.C magnetron sputtering
...Show More Authors

Cadmium oxide thin films were prepared by D.C magnetron plasma sputtering using different voltages (700, 800, 900, 1000, 1100 and 1200) Volt. The Cadmium oxide structural properties using XRD analysis for just a voltage of 1200 volt at room temperature after annealing in different temperatures (523 and 623) K were studied .The results show that the films prepared at room temperature have some peaks belong to cadmium element along the directions (002), (100), (102) and (103) while the other peaks along the directions of (111), (200) and (222) belong to cadmium oxide. Annealed samples display only cadmium oxide peaks. Also, the spectroscopic properties of plasma diagnostic for CdO thin films were determined and the results show that the el

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Apr 19 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Separation and determination of poly aromatic hydrocarbons in vegetables samples in Baghdad city using HPLC Technique
...Show More Authors

The Reversed Phase High Performance Liquid Chromatography (RP-HPLC) has been used for the separation of Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage of the heavy water ,industrial trash and trash of oil colanders. -

... Show More
Publication Date
Mon Dec 01 2025
Journal Name
Research Journal Of Chemistry And Environment
HPLC and Atomic Absorption Spectrometry for the Analysis of Pharmacological Activities in Soursop
...Show More Authors

Soursop is useful in treating diseases and the bioactive components of the fruit are beneficial in the treatment of gastrointestinal parasites. Annona muricata contains flavonoids, phenolic acids, and tannins in its leaves, pulp, and seeds. The current study provided an accurate analytical method for the pharmacologically active components, including glutathione, potassium, and vitamin B6, in soursop fruit samples of soursop using high-performance liquid chromatography and atomic absorption spectrometry. The fruits of the soursop were cleaned, peeled, and sliced into tiny pieces. The juice was chilled and kept in glass bottles. After blending the fruits with distilled water, they were placed on a magnetic stirrer and left for 72 hours. For

... Show More