Preferred Language
Articles
/
bsj-2889
Molecular diagnosis of E.coliO157:H7 Which Isolated from Children with Diarrhea by using Multiplex PCR
...Show More Authors

A total of 96 stool samples were collected from children with bloody diarrhea from two hospitals in Baghdad. All samples were surveyed and examined for the presence of the Escherichia coli O157:H7 and differentiate it from other Non -Sorbitol Fermenting Escherichia coli (NSF E. coli). The Bacterial isolates were identifed by using morphological diagnostic methods, Samples were cultured on liquid enrichment medium, incubated at 37C? for 24 hrs, and then cultured on Cefixime Tellurite -Sorbitol MacConkey Agar (CT- SMAC). 32 non-sorbitol fermenting bacterial isolates were obtained of which 11 were identified as Escherichia coli by using traditional biochemical tests and API20E diagnostic system without differentiation between serotype O157:H7 and other NSF E. coli isolates . Four special biochemical tests were done for serotype O157:H7 differentiation from other NSF bacteria. Only 3 isolates belonging to the serotype O157:H7 were obtained . Latex agglutination test for O157 and H7 showed that the 3 isolates gave positive results with both tests. The Bacterial isolates were identifed by using Multiplex Polymerase Chain Reaction (MPCR) technology for the presence or absence of 4 genes (Stx1, Stx2, hlyA and eaeA) that encode for main virulence factors to diagnose E. coli O157:H7 isolated By using specific primers in MPCR . The result showed that one E. coli O157:H7 isolates contain all 4 genes , other isolates contain 3 genes: Stx2, hlyA & eaeA.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jul 21 2023
Journal Name
Journal Of Engineering
Water Recovery from Brine Solution by Forward Osmosis Process
...Show More Authors

The present work aims to study the possibility of utilization a forward osmosis desalination process as an alternative method to extract water from brine solution rejected from reverse osmosis process.
Experiments conducted in a laboratory–scale forward osmosis (FO) unit in cross flow flat sheet membrane cell yielded water flux ranging from (0.0315 to 0.56 L/m2 .min) when using CTA membrane,and ranging from (0.419 to 2.785 L/m2 .min) for PA membrane under 0.4 bar. Two possible membrane orientations were tested. Sodium chloride with high concentrations was used as draw solution solute. The effect of membrane orientation on internal concentration polarization (ICP) was studied. Two regimes of ICP; dilutive and concentrative were desc

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sun May 02 2021
Journal Name
Knowledge-based Engineering And Sciences
Lead sorption from aqueous solutions by kaolinite: laboratory experiments
...Show More Authors

The lead has adverse effects in contamination the aquatic environment, for this reason, a laboratory simulation was conducted using kaolinite collected from the Ga’ara Formation at western Iraq to be considered as a natural sorbent material that can be addressed Pb2+ from the aqueous environments. The Energy-Dispersive X-ray Spectroscopy and atomic absorption spectroscopy clarifying very fine grains and pure phase with a very little quantity of quartz and has a number of active sites for adsorption. The sorption of kaolinite for the Pb2+ has been carefully tested by several designed laboratory experiments. Five lead solutions of different concentrations (25, 50, 75, 100 and 125 ppm) were tested under different values of pH (1.3-9)

... Show More
View Publication
Crossref (4)
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Journal Of Ecological Engineering
Cadmium Removal from Contaminated Soil by Electro-Kinetic Method
...Show More Authors

View Publication
Scopus (6)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sun Apr 30 2023
Journal Name
Al-kindy College Medical Journal
Ultrasound Guided Core Needle Biopsy in The Diagnosis of Suspicious Breast Lesions: Radiologist’s perspectives
...Show More Authors

Background: Ultrasound guided core needle biopsy is becoming a gold standard in the work up of suspicious breast lesion. In Iraq, radiologists are not taking the lead in core needle biopsy performance.

Objectives: To evaluate the radiologist performance of core needle biopsy highlighting the precession and accuracy of the procedure, the concordance of ultrasound and histopathology, and identifying challenges facing the radiologist during the procedure.

Subjects and Methods: A prospective study involving a total of 50 patients with ultrasound (US) BIRADS IV or V.  Ultrasound guided core needle biopsy was performed for each patient. Surgical pathol

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Mon Dec 01 2008
Journal Name
Al-khwarizmi Engineering Journal
Extraction of Phenol From Industrial Water Using Different Solvents
...Show More Authors

The analysis and efficiency of phenol extraction from the industrial water using different solvents, were investigated. To our knowledge, the experimental information available in the literature for liquid-liquid equilibria of ternary mixtures containing the pair phenol-water is limited. Therefore the purpose of the present investigation is to generate the data for the water-phenol with different solvents to aid the correlation of liquid-liquid equilibria, including phase diagrams, distribution coefficients of phenol, tie-lines data and selectivity of the solvents for the aqueous phenol system.

                The ternary equilibrium diagrams and tie-lines

... Show More
View Publication Preview PDF
Publication Date
Sat Sep 30 2023
Journal Name
Iraqi Geological Journal
Purification of Aqueous Solutions from Nickel Using Ceramic Waste
...Show More Authors

This study aims to test ceramic waste's capacity to remove nickel from aqueous solutions through adsorption. Ceramic wastes were collected from the Refractories Manufacturing Plant in Ramadi. Through a series of lab tests, the reaction time (5, 10, 15, 20, 25, 30, 35, 40, 45, and 50 minutes, and Ni concentrations (20, 40, 60, and 80) were tested using ceramic wastes with a solid to liquid ratio of 2g/30ml. At a temperature of 30ºC, the pH, total dissolved solids (TDS), and electrical conductivity (EC) were all measured. The equilibrium time was set at 30 min. Thereafter, the sorption (%) somewhat increased positively with the Ni concentration. Freundlich's equation showed that the adsorption intensity is 1.1827 and the Freundlich c

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sat Mar 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Adsorption of Phenol from Aqueous Solution using Paper Waste
...Show More Authors

The exploitation of obsolete recyclable resources including paper waste has the advantages of saving resources and environment protection. This study has been conducted to study utilizing paper waste to adsorb phenol which is one of the harmful organic compound byproducts deposited in the environment. The influence of different agitation methods, pH of the solution (3-11), initial phenol concentration (30-120ppm), adsorbent dose (0.5-2.5 g) and contact time (30-150 min) were studied. The highest phenol removal efficiency obtained was 86% with an adsorption capacity of 5.1 mg /g at optimization conditions (pH of 9, initial phenol concentration of 30 mg/L, an adsorbent dose of 2 g and contact time of 120min and at room temperature).

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sun Sep 04 2016
Journal Name
Baghdad Science Journal
The Removal of Zinc from Aqueous Solutions Using Malvaparviflora
...Show More Authors

In this study, the adsorption of Zn (NO3)2 is carried out by using surfaces of malvaparviflora. The validity of the adsorption is evaluated by using atomic absorption Spectrophotometry through determination the amount of adsorbed Zn (NO3)2. Various parameters such as PH, adsorbent weight and contact time are studied in terms of their effect on the reaction progress. Furthermore, Lagergren’s equation is used to determine adsorption kinetics. It is observed that high removal of Zn (NO3)2 is obtained at PH=2. High removal of Zn (NO3)2 is at the time equivalent of 60 min and reaches equilibrium,where 0.25gm is the best weight of adsorbant . For kinetics the reaction onto malvaparviflora follows pseudo first order Lagergren’s equation.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Dec 25 2019
Journal Name
Journal Of Engineering
Removal of Cadmium from Industrial Wastewater using Electrocoagulation Process
...Show More Authors

Cadmium is one of the heavy metal found in the wastewater of many industries. The electrocoagulation offers many advantages for the removal of cadmium over other methods. So the removal of cadmium from wastewater by using electrocoagulation was studied to investigate the effect of operating parameters on the removal efficiency. The studied parameters were the initial pH, initial concentration, and applied voltage. The study experiments were conducted in a batch reactor with  with two pairs of aluminum electrodes with dimension  and 2mm in thick with 1.5 cm space between them. The optimum removal was obtained at pH =7, initial concentration = 50 mg/L, and applied voltage = 20 V and it was 90%.

View Publication Preview PDF
Crossref (9)
Crossref
Publication Date
Wed Sep 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Tetracycline from Wastewater Using Circulating Fluidized Bed
...Show More Authors

   In this study, the circulating fluidized bed was used to remove the Tetracycline from wastewater utilizing a pistachio shell coated with ZnO nanoparticles. Several parameters including, Tetracycline solution flowrate, initial static bed height, Tetracycline initial concentration and airflow rate were systematically examined to show their effect on the breakthrough curve and the required time to reach the adsorption capacity and thus draw the fully saturated curve of the adsorbent. Results showed that using ZnO nanoparticles will increase the adsorbent surface area and pores and as a result the adsorption increased, also the required time for adsorbent saturation increased and thus the removal efficiency may be achieved at mi

... Show More
View Publication Preview PDF
Crossref (19)
Crossref