This work represents implementation and investigation of optical coherent communication system between two computers. A single mode optical fiber is selected as transmission medium. The data are sent via the RS-232 standard interface with a bit rate of 9.6 kbps from personal computer (PC1) by line receive to convert the data from electrical levels (-12/+12 V) into TTL level (0/5 V). The modulation of this data was accomplished by internal modulation using laser diode type (HFCT-5208M) 1310 nm wavelength. The optical D-coupler was used to combine the optical signal that come from laser source with optical signal of laser local oscillator (OTS-304XI) at 1310/1550 nm wavelength to obtain coherent (homodyne and heterodyne) detection respectively. A PIN photodetector (HFCT-5208M) is used. Calculations of Signal to Noise Ratio (SNR) and Bit Error Rate (BER) for coherent detection were measured at different length of the optical fiber. Result show that high SNR and low BER for heterodyne detection than for homodyne detection.
Convolutional Neural Networks (CNN) have high performance in the fields of object recognition and classification. The strength of CNNs comes from the fact that they are able to extract information from raw-pixel content and learn features automatically. Feature extraction and classification algorithms can be either hand-crafted or Deep Learning (DL) based. DL detection approaches can be either two stages (region proposal approaches) detector or a single stage (non-region proposal approach) detector. Region proposal-based techniques include R-CNN, Fast RCNN, and Faster RCNN. Non-region proposal-based techniques include Single Shot Detector (SSD) and You Only Look Once (YOLO). We are going to compare the speed and accuracy of Faster RCNN,
... Show MoreExperimental research was carried out to investigate the effect of fire flame (high temperature) on specimens of short columns manufactured using SCC (Self compacted concrete). To simulate the real practical fire disasters, the specimens were exposed to high
temperature flame, using furnace manufactured for this purpose. The column specimens were cooled in two ways. In the first the specimens were left in the air and suddenly cooled using water, after that the specimens were loaded to study the effect of degree of
temperature, steel reinforcement ratio and cooling rate, on the load carrying capacity of the reinforced concrete column specimens. The results will be compared with behaviour of columns without burning (control specime
Meta stable phase of SnO as stoichiometric compound is deposited utilizing thermal evaporation technique under high vacuum onto glass and p-type silicon. These films are subjected to thermal treatment under oxygen for different temperatures (150,350 and 550 °C ). The Sn metal transformed to SnO at 350 oC, which was clearly seen via XRD measurements, SnO was transformed to a nonstoichiometric phase at 550 oC. AFM was used to obtain topography of the deposited films. The grains are combined compactly to form ridges and clusters along the surface of the SnO and Sn3O3 films. Films were transparent in the visible area and the values of the optical band gap for (150,350 and 550 °C ) 3.1,
This contribution reports a comprehensive investigation into the structural, electronic and thermal properties of bulk and surface terbium dioxide (TbO2); a material that enjoys wide spectra of catalytic and optical applications. Our calculated lattice dimension of 5.36 Å agrees well with the corresponding experimental value at 5.22 Å. Density of states configuration of the bulk structure exhibits a semiconducting nature. Thermo-mechanical properties of bulk TbO2 were obtained based on the quasi-harmonic approximation formalism. Heat capacities, thermal expansions and bulk modulus of the bulk TbO2 were obtained under a wide range of temperatures and pressures. The dependency of these properties on operational pressure is very evident. Cle
... Show MoreThe concept of forming the living space in the American strategic thought has an
important position it is regarded as an strategic movement that it supports the American
United States with the huge capabilities in its own concern that enables it to approach of
American administration , we find that of different historical periods it works to establish that
the geopolitical dimension which is accompanied with the ability of American response for
the evens that in its own turn enables the American united states to seize the growing chances
in the global strategic environment This study includes five chapters :
- Chapter one: The idea of living space.
- Chapter two: Geopolitical dimension of living space theory.
-
Background: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber. Aim: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. Methods: Sixty eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design) in the Eye Specialty Private Hospital, Baghdad, Iraq were studied. The mean spherical refraction was -11.32±3.17 diopter (D) with a range of -6.00 to -18.00 D and a mean cylinder of -2.61±1.16 with range of -1.00 to -5.50 D. The outcome measures that evaluat
... Show MoreMulti-drug-resistant uropathogenic Escherichia coli (UPEC) is considered a significant challenge due to its ability to resist antibiotics and form biofilms. UPEC biofilm formers are well protected and largely inaccessible to antibiotics, which leads to persistent infections and evasion of the host immune system. Understanding how ciprofloxacin and trimethoprim/sulfamethoxazole affect biofilm formation is essential for improving treatment strategies for urinary tract infections (UTIs). A total of 76 UPEC isolates were obtained from Iraqi patients and identified using morphological and biochemical characteristics, as well as the Vitek®-2 Compact system. Minimum inhibitory concentrations (MICs) were determined using the Vitek®-2 system, whic
... Show More