Measurement of Alpha Emitters Concentration in Tomato Fruits Using CR – 39 Plastic Track Detector
...Show More Authors

Our country suffered from pollution translation as a result to the wars events, so, it is necessary to measure the amount of radiation in the fields that are of indirect contact with human life and health. The main aim of the present work is to measure the concentration of alpha emitters in tomato fruits collected from different farms in Al – Basra governorate in the south of Iraq. Nuclear track detectors of type CR – 39 are used as a detection device and Can technique as a detection technique. Results show that the maximum concentration recorded is sample no.7 of site Al – Rafidhya which was equal to (6.9621 ± 0.111) ppm and sample no.1 of site Lothan with concentration equals to (4.9236 ± 0.117) ppm. The minimum concentrations were in sample 6 of site Al – Lehaiss (1.5360 ± 0.084) ppm followed by sample 9 of site Malhan which recorded (1.6840 ± 0.111) ppm (20.208 ± 1.332 Bq/m3).

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jan 01 2017
Journal Name
Research Journal Of Applied Sciences
interaction of alpha particles with Overy tissue
...Show More Authors

Nuclear medicine is important for both diagnosis and treatment. The most common treatment for diseases is radiation therapy used against cancer. The radiation intensity of the treatment is often less than its ability to cause damage, so radiation must be carefully controlled. The interactions of alpha particle with matter were studied and the stopping powers of alpha particle with ovary tissue were calculated using Beth-Bloch equation, Zeigler’s formula and SRIM Software also the range and Liner Energy Transfer (LET) and ovary thickness as well as dose and dose equivalent for this particle were calculated by using Matlab language for (0.01-200) MeV alpha energy.

Publication Date
Tue Oct 11 2022
Journal Name
College Of Islamic Sciences
The purposes of faith and its fruits in the light of the letters of light Prepare
...Show More Authors

What is meant by objectives: the purpose, secrets, judgment, and interests that the legislator set for each of its rulings is a doctrine and a law.

Faith is belief with certainty in God Almighty, and what is required of him in his divinity, lordship, names and attributes, belief in his angels, books, messengers, the Last Day and destiny, both good and bad.

And the purposes of faith are the wisdom and secrets contained in the Islamic faith and which achieve human well-being and happiness in the immediate and the future. And that the purposes of belief and faith are the essence of religion, rather it constitutes a basic pillar on which the basis of the intentional consideration as a whole, because the structure of worship i

... Show More
View Publication Preview PDF
Publication Date
Mon Apr 01 2019
Journal Name
International Journal Of Research - Granthaalayah
CALCULATION OF THE STOPPING POWER OF ALPHA PARTICLES AND ITS RANGE IN BONE TISSU
...Show More Authors

With the advancement of modern radiotherapy technology, radiation dose and dose distribution have significantly improved. as part of Natural development, interest has recently been renewed by treatment, especially in the use of heavy charged particles, because these radiation types serve theoretical advantages in all biological and physical aspects. The interactions of alpha particle with matter were studied and the stopping powers of alpha particle with Bone Tissue were calculated by using Zeigler’s formula and SRIM software, also the Range for this particle were calculated by using Mat lab language for (0.01-1000) MeV alpha energy.

Publication Date
Mon Jul 20 2020
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Determined the Concentration Elements to Human Nail Using X- Ray Fluorescence Technique
...Show More Authors

Cancer constitutes a serious disease and a major health problem in worldwide, a lot of people were infected with this dangerous disease, Therefore, there must be attention to this disease through diagnosis and prevention there. In this study, we determined the relationship between the Cancer and the concentration of trace elements by comparing the concentration trace elements for infected and non-infected people. The trace elements concentrations to nails are one of the diagnostic criteria that easily to detect and dated this disease without any harm to the patient. Eight nails samples were collected from cancer-infected and eight samples from non-infected of the relatives of first-degree. All samples were measured by the concentrations

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Oct 01 2021
Journal Name
Journal Of Engineering
Some Geotechnical Properties of Plastic Soil Enhanced with Cement Dust
...Show More Authors

Plastic soil exhibits unfavorited geotechnical properties (when saturation), which causes negative defects to engineering structures. Different attempts (included various materials) were conducted to proffer solutions to such defects by experimenting in practical ways. On one hand, these attempts aimed to improve the engineering characteristics of plastic soil, and on the other hand, to use problematic waste materials as a stabilizer, like cement kiln dust, and to reduce environmental hazards. This paper explored the shrinkage, plasticity, and strength behavior of plastic soil enhanced with cement dust. The cement dust contents were 0%, 5%, 10%, 15% and 20% by dry weight of soil. An experimental series of shrinkage and p

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Jan 20 2020
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Estimation of Uranium Concentration in Urine Samples of Kidneys Failure Patients in Al- Muthanna Governorate
...Show More Authors

   The measurement of uranium concentration in human urine is very important in assessment of occupational and public exposure to uranium. In the present work, the fission track technique was used to decide uranium concentration in blood of Kidneys Failure Patients in Al- Muthanna Governorate. The uranium concentration values in urine samples of Kidneys Failure Patients ranged between 0.92  to 4.87  , while Healthy group results were ranged 0.91  to 1.82 . Results showed that the concentration of uranium in the URINE increases in kidney failure patients

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Oct 02 2020
Journal Name
International Journal Of Pharmaceutical Research
A turbidimetric method for the quantitative determination of cyproheptadine hydrochloride in tablets using an optoelectronic detector based on the LEDs array
...Show More Authors

View Publication Preview PDF
Scopus (11)
Crossref (2)
Scopus Crossref
Publication Date
Thu Oct 17 2019
Journal Name
International Journal Of Research In Social Sciences And Humanities
A CRITICAL DISCOURSE ANALYSIS OF RHETORICAL DEVICES OF TRUMP'S AND MAY'S SPEECHES DURING THE PERIOD 2017 TO 2019
...Show More Authors

DBNRHM Sami, International Journal of Research in Social Sciences and Humanities, 2020

View Publication
Publication Date
Mon Jan 01 2024
Journal Name
Current Research In Pharmacology And Drug Discovery
Papaverine attenuates the progression of alpha naphthylisothiocyanate induce cholestasis in rats
...Show More Authors

View Publication
Scopus (6)
Crossref (5)
Scopus Crossref
Publication Date
Fri Nov 29 2019
Journal Name
Iraqi Journal Of Physics
Estimating sugar concentration in human blood serum using Surface Plasmon Resonance (SPR) –based optical fiber sensor
...Show More Authors

Surface Plasmon Resonance (SPR)-based plastic optical fiber sensor for estimating the concentration and refractive index of sugar in human blood serum. The sensor is fabricated by a small part (10mm) of optical fiber in the middle is embedded in a resin block and then the polishing process is done, after that it is deposited with about (40nm) thickness of gold metal. The blood serum is placed on gold coated core of an Optical grade plastic optical fiber of 980 µm core diameter.

View Publication Preview PDF
Crossref (5)
Crossref