The aim of this research was to study the concentrations of Uranium in the phosphorus fertilizers using Nuclear track detector (CR-39). Our present investigation is based on the study of 10 types samples for different kinds of phosphorus fertilizers which were available in the local market Some of them were Iraqi made and the others from different countries like, (Iran, Italy, Holland, Lebanon and Jordan) .. The result obtained shows that the Uranium concentration in phosphorus fertilizers samples varies from (3.59ppm) to(2.59ppm). Based on the radioactive concentration of Uranium in the samples all the results obtained between(3.59ppm) in the Iraqi super phosphate to (2.59ppm) in the mixture Iraqi phosphate fertilizer are within the international levels as given by IAEA (International atomic Energy Agency) date if compares that equal by 12ppm .
Tea is one of the important liquids that people drink. In Iraq, tea is the main beverage after water. The tea plant is known scientifically as Camellia sinensis, when planting and during growth needs to fertilizers, which contents remarkable amounts of Uranium. So it became important to study the concentrations of uranium found in tea. Eight samples of tea had been taking, which represent the most important species used in the Iraqi kitchen, and the Uranium concentrations were measured. The results showed that the average concentration of uranium for all samples were1.005 mg/L, while the average of the annual effective dose was 0.221 mSν/y. The results also indicated that green tea possesses small concentration of Uranium compared with
... Show MoreThe present work aims to evaluate the content of some toxic metals in chemical and organic fertilizers purchased from local markets in Baghdad, Iraq. The analysis was performed by laser-induced breakdown spectroscopy (LIBS) system. The emission spectral lines of lead (Pb), chromium (Cr), cadmium (Cd) and cobalt (Co) have been recorded to determine the best peak representing each element according to the NIST database. The validity of the LIBS procedure was checked by cross-validating the obtained results using atomic absorption spectroscopy (AAS) with a maximum relative error of 5.3%. Moreover, for qualitative analysis, Pb I 296.64 nm emission line was determined to be superior for the evaluation of lead content in terms of three
... Show MoreThe paper aims to propose the maximum track length (Lmax) measurement as an alternative approach to evaluate and extract the bulk etch rate (Vb) of the nuclear detector PADC CR-39, and compare it with the results obtained by the removal layer thickness measurement of the etched detector. The alternative Lmax-method mainly relies on the measuring the length of the etched tracks, their maximum values and saturation times from the obtained track profile images. The detectors were irradiated with different energies of alpha particles emitted from the 241Am source and then etched in a 6.5 N NaOH solution at 70±1oC for different successive time intervals. In
... Show MoreThe aim of this work is to determine radon and its decay product concentratiQns indoor and outdoor in different areas in north and middle are·a of Iraq by using nuclear trak detectors , CR-39 , CN- 85 andLR-115. -
For CR-39 detectors , the highest radon concentration was
(64.07Bq/m3)indoor and (52.4 Bq/m3)
outdoor &n
... Show MoreIn this study , extraction of irradiated high concentration hexavallent uranium from fission products ( high gamma radiation ) was carried out using multistages countercurrent continuous technique (mixer setller) , employing this technique requires a designing flow sheet that recover all the amounts of uranium and to minimize its losses in the nuclear waste streams. Due to the several parameters required to reach this design, SEPHIS program which is one of the famous code in this field were used to select the optimum conditions through many theoretical runs , finally the experimental results give a good assurance in SEPHIS results and its optimum conditions.
The photonconductor detectors CdSe:Cu was fabricated as a thin film of (1 μm) in thickness using vacuum evaporation technique. doping with copper was made using vacuum annealing at 350oC under argon atmosphere . The spectral responsivity and spectral detectivity of the detector were determined as a function of incident wavelength on the sample. A remarkable improvement in performance was absorbed for the specimen, which doping with (1-5 wt%) Cu.
The spectral response increases with increasing of wavelength for incident radiation to maximum value, after that , it reduced sharply . There is a shifting for peak responsivity indirect of higher wavelength. The detectivity was increased with doping but its decreased as the concentration in
BN Rashid, AJES, 2014