Preferred Language
Articles
/
bsj-2832
Flow injection analysis for the photometric determination of promethazine-HCl in pure and pharmaceutical preparation via oxidation by persulphate using Ayah 3SX3-3D solar micro photometer
...Show More Authors

The first flow injection spectrophotometric method is characterized by its speed and sensitivity which have been developed for the determination of promethazine-HCl in pure and pharmaceutical preparation. It is based on the in situ detection of colored cationic radicals formed via oxidation of the drug with sodium persulphate to pinkish-red species and the same species was determined by using homemade Ayah 3SX3-3D solar flow injection photometer. Optimum conditions were obtained by using the high intensive green light emitted diode as a source. Linear dynamic range for the absorbance versus promethazine-HCl concentration was 0-7 mmol.L-1, with the correlation coefficient (r) was 0.9904 while the percentage linearity (r2%) was 98.09%. the L.O.Q was 3.97 µg/sample, while L.O.D (S/N=3) = 0.2407µg/sample (5 µmol.L-1) from the stepwise dilution for the minimum concentration of lowest concentration in the linear dynamic range of the calibration graph. The R.S.D% at 2 mmol.L-1 promethazine-HCl is less than 1% (eight replicates) using 150 µL sample volume. Throughput 30 sample.hr-1. The method was applied successfully for the determination of promethazine-HCl in pharmaceutical preparation. By using paired t-test it was shown that there was no significant difference between the proposed method and official method and on that basis the new method can be accepted as an alternative analytical method.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jan 01 2009
Journal Name
Wasit Journal For Science & Medicine
Spectrophotometric Determination of Promethazine Hydrochloride by In (III)
...Show More Authors

A simple, rapid and sensitive spectrophotometirc method for the determination of trace amounts of promethazine hydrochloride in the aqueous solution is described. The method is based on the complexation of promethazine hydrochloride with In (III) in the presence of sodium hydroxide to form an soluble product with maximum absorption at 304nm. Beer’s law is obeyed over the concentration range of (2- 20μg/ml) with molar absorptivity of (1.92× 103 L.mol-1 .cm -1 ). The optimum conditions for all development are described and the proposed method has been successfully applied for the determination of promethazine hydrochloride in bulk drug.

Publication Date
Sat Jan 01 2022
Journal Name
Chemical Methodologies
Determination of the Quantity of Losartan Active Ingredient in the Medication Formulations via Turbidimetric-Flow Injection Technique
...Show More Authors

Scopus (14)
Scopus
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
Spectrophotmetric Micro determination of promrthazine hydrochloride in pharmaceutical
...Show More Authors

a simple accurate and sensitive spectrophotometric method for the determination of promethazine HCI has been developed the method is based on the oxidative coupling reaction of promethazine

View Publication Preview PDF
Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Baghdad Science Journal
Spectrophotometric Analysis of Vancomycin Hydrochloride in Pure and Pharmaceutical Injections via Batch and Cloud Point Extraction Techniques
...Show More Authors

Development of a precise and delicate reaction has been acquired for the determination of vancomycin hydrochloride using batch and cloud point extraction (CPE) methods. The first method is based on the formation of azo dye as a result of diazotized dapsone coupled with vancomycin HCl (VAN) in a basic medium. The sensitivity of this reaction was enhanced by utilizing a nonionic surfactant (Triton X-114) and the cloud point extraction technique (second method). The azo dye formed was extracted into the surfactant-rich phase, dissolved in ethanol and detected at λmax 440 nm spectrophotometrically. The reaction was investigated using both batch and CPE methods (with and without extraction), and a simple comparison between the two

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Sun Nov 01 2015
Journal Name
Karbala International Journal Of Modern Science
Batch and flow injection spectrophotometric methods for the determination of barbituric acid in aqueous samples via oxidative coupling with 4-aminoantipyrine
...Show More Authors

A batch and flow injection (FI) spectrophotometric methods are described for the determination of barbituric acid in aqueous and urine samples. The method is based on the oxidative coupling reaction of barbituric acid with 4-aminoantipyrine and potassium iodate to form purple water soluble stable product at λ 510 nm. Good linearity for both methods was obtained ranging from 2 to 60 μg mL−1, 5–100 μg mL−1 for batch and FI techniques, respectively. The limit of detection (signal/noise = 3) of 0.45 μg mL−1 for batch method and 0.48 μg mL−1 for FI analysis was obtained. The proposed methods were applied successfully for the determination of barbituric acid in tap water, river water, and urine samples with good recoveries of 99.92

... Show More
View Publication
Scopus (13)
Crossref (5)
Scopus Crossref
Publication Date
Sun Jun 07 2015
Journal Name
Baghdad Science Journal
Flow Injection Spectrophotometric Determination of Thymol using 4-Aminoantipyrine and Copper(II) Nitrate
...Show More Authors

Flow-injection (FI) spectrophotometric method has been developed for the analysis of thymol in pharmaceutical preparations. The method is based on organic coupling reaction between thymol and 4-amino antipyrine in the presence of alkaline medium to form an intense stable red color complex with copper nitrate that has a maximum absorption at 490 nm. Optimum conditions for determination of the drug was investigated .The calibration graph was linear over the range of 5-500 µg.ml-1 of thymol . The limit of detection (LOD) and limit of quantification (LOQ) were 1.81 ?g mL-1 and 3.60 ?g mL-1 respectively .The proposed method was applied satisfactorily to the determination of thymol in mouth wash preparations. The procedure is characterized by

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Mar 02 2008
Journal Name
Baghdad Science Journal
Determination Of Micro Amount Of Spironolactone In Some Of Pharmaceutical Preparate By Using a Molecular Luminescence Technique.
...Show More Authors

The present study include a new developed method of analysis for determination of drug Spironolaction (SP) in some Pharmaceuticals by Spectrofluorometric method. Spironolaction was determined under optimal experimental condition that follows :- The excitation spectrum was (l=351 nm), the emmetion spectrum was (l=518 nm), pH=1, the suitable temperature for reaction 60oC and the optimal time less than (3) minute. The analysis and rang statistical data was:-Linear dynamic rang (1-10) ?g.ml-1, the detection limit (D.L = 0.023 ?g.ml-1), Molar absorptivity (? = 29875 liter mole-1 cm-1), Relative standard deviation (%RSD = 0.78), (%Erel = 3.3) and recovery (Rec = 96.6) percentage. Determination of Spironolactone was accomplished by two methods

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 09 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Chromium Using Promethazine Hydrochloride - Application in Various Sample
...Show More Authors

       A rapid, simple and sensitive spectrophotometric method for the determination of trace amounts of chromium (VI) was studied. The method is based on the reaction of chromium (VI) with promethazine forming a red colored species by chromium in hydrochloric acid  medium  and exhibits  a maximum absorbance at 518 nm. A plot of absorbance with chromium (VI) gives a straight line indicating that  Beer’s law has been obeyed over the range concentration of 0.05-4.0 µg/ml with a molar absorptivity of chromium(VI) 2.04 ï‚´ 104       l.mol-1.cm-1 , Sandell’s sensitivity index of 0.0025 µg.cm-2  while the limit of detection (LOD) was found to be 0.0924 µg.ml

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 14 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Diclofenac sodium Using 2,4-dinitrophenylhydrazine in Pure Form and Pharmaceutical Preparations
...Show More Authors

A simple and sensitive spectrophotometric method is described for the determination of diclofenac sodium (DCL), in pure form and pharmaceutical formulations. The method is based on the oxidation of 2,4-dinitrophenylhydrazine (2,4-DNPH) and coupling of the oxidized product with DCL in alkaline medium to give intensively colored chromogen which exhibits maximum absorption (λmax) at 600 nm, and the concentration of DCL was determined spectrophotometrically. The optimum reaction conditions and other analytical parameters were evaluated. In addition to classical univariate optimization, modified simplex method (MSM) has been applied in optimization of the variables affecting the color producing reaction. Beer’s law is obeyed in the

... Show More
View Publication Preview PDF
Publication Date
Fri Nov 20 2015
Journal Name
Iraqi Journal Of Science
New Approach for Determination of Oxonium Ion in Inorganic Acids by Quenched Fluorescence of Analytically Interested Species via the Liberated Bromine Using Continuous Flow Injection Laser Diode Fluorimeter Analyser
...Show More Authors

A new method is characterized by simplicity, accuracy and speed for determination of Oxonuim ion in ionisable inorganic acid such as hydrochloric (0.1 - 10) ,Sulphuric ( 0.1 - 6 ),nitric ( 0.1 - 10 ), perchloric ( 0.1 - 7 ), acetic (0.1 - 100 ) and phosphoric ( 0.1 - 30 ) ( mMol.L-1 )acids. By continuous flow injection analysis. The proposed method was based on generation of bromine from the Bro-3-Br-- H3O+. Bromine reacts with fluorescein to quenches the fluorescence . A sample volume no.1 (31μl) and no.2 (35μl) were used with flow rate of 0.95 mL.min-1 using H2O line no.1as carrier stream and 1.3 mL.min-1 using fluorescein sodium salt line no.2. Linear regression of the concentration ( mMol.L-1 ) Vs quenched fluorescence gives a correla

... Show More
View Publication