Preferred Language
Articles
/
bsj-2832
Flow injection analysis for the photometric determination of promethazine-HCl in pure and pharmaceutical preparation via oxidation by persulphate using Ayah 3SX3-3D solar micro photometer
...Show More Authors

The first flow injection spectrophotometric method is characterized by its speed and sensitivity which have been developed for the determination of promethazine-HCl in pure and pharmaceutical preparation. It is based on the in situ detection of colored cationic radicals formed via oxidation of the drug with sodium persulphate to pinkish-red species and the same species was determined by using homemade Ayah 3SX3-3D solar flow injection photometer. Optimum conditions were obtained by using the high intensive green light emitted diode as a source. Linear dynamic range for the absorbance versus promethazine-HCl concentration was 0-7 mmol.L-1, with the correlation coefficient (r) was 0.9904 while the percentage linearity (r2%) was 98.09%. the L.O.Q was 3.97 µg/sample, while L.O.D (S/N=3) = 0.2407µg/sample (5 µmol.L-1) from the stepwise dilution for the minimum concentration of lowest concentration in the linear dynamic range of the calibration graph. The R.S.D% at 2 mmol.L-1 promethazine-HCl is less than 1% (eight replicates) using 150 µL sample volume. Throughput 30 sample.hr-1. The method was applied successfully for the determination of promethazine-HCl in pharmaceutical preparation. By using paired t-test it was shown that there was no significant difference between the proposed method and official method and on that basis the new method can be accepted as an alternative analytical method.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Mar 29 2018
Journal Name
Construction Research Congress 2018
Consideration of Worker Safety in the Design Process: A Statistical-Based Approach Using Analysis of Variance (ANOVA)
...Show More Authors

View Publication
Scopus (2)
Crossref (3)
Scopus Crossref
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Preparation and Evaluation of Chloramphenicol as Thermosensitive Ocular in- situ Gel
...Show More Authors

The purpose of this study was to develop poloxamer-based in-situ gel of chloramphenicol aiming to increase bioavailability and prolong corneal contact time, controlling drug release, and enhancing ocular bioavailability. The in-situ gel was prepared using different concentrations of poloxamer 407 combined with hydroxypropyl methyl cellulose (HPMC) or carbapol 940 to achieve gelation temperature about physiological temperature and improve rheological behavior and gelling properties of poloxamer gel. The prepared formulations were evaluated for their appearance, pH, and sol-gel transition temperature. The formulations F2, F3, and F5 have a gelation temperature within the accepted range 35-370C an

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Wed Jul 24 2024
Journal Name
مداد الآداب
Navigating the Evolving Tourism Landscape: Examining the Challenges and Opportunities for TripAdvisor and Travelocity in the Era of AI:A Comparative Analysis of Innovation Strategies
...Show More Authors

The tourism industry has undergone exponential transformation, reshaped by online travel agencies (OTAs), shifting consumer preferences, and technological advancements. Established OTAs like TripAdvisor and Travelocity face pressures to adapt their strategies to capitalize on these disruptive landscape changes. This research involves a comparative analysis examining the key challenges confronting TripAdvisor and Travelocity, with a focus on opportunities to leverage artificial intelligence (AI) in enhancing personalization and the traveler experience. The study utilizes publicly available data on the companies and academic literature on AI innovation diffusion. Findings reveal that while TripAdvisor has actively developed AI-based trip plan

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 01 2010
Journal Name
Iraqi Journal Of Physics
Study of electron energy distribution function and transport parameters for CF4 and Ar gases discharge by using the solution of Boltzmann equation-Part I
...Show More Authors

The Boltzmann transport equation is solved by using two- terms approximation for pure gases . This method of solution is used to calculate the electron energy distribution function and electric transport parameters were evaluated in the range of E/N varying from . 172152110./510.VcmENVcm
From the results we can conclude that the electron energy distribution function of CF4 gas is nearly Maxwellian at (1,2)Td, and when E/N increase the distribution function is non Maxwellian. Behavior of electrons transport parameters is nearly from the experimental results in references. The drift velocity of electron in carbon tetraflouride is large compared with other gases

View Publication Preview PDF
Publication Date
Mon Jul 01 2013
Journal Name
Diyala Journal For Pure Sciences
Multipole Mixing Ratios for Gamma transitions in 56Fe populated in Reaction by using least square fitting method .
...Show More Authors

The γ- mixing ratios of γ- transitions from levels of 56Fe populated in reaction are calculated using least square fitting program for the first time in the case of pure and mixed transitions the results obtained have been compound with γ Values determined by other methods .The comparison shows that the agreement is good this confirmed the valilety of this method in calculating of values for such γ- transitions key word: γ- transition ,Multipole mixing ratios ,Least square fitting method.

Publication Date
Fri Mar 15 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of the correlation between the tensile and diametrical compression strengths of 3D-printed denture base resin reinforced with ZrO2 nanoparticles
...Show More Authors

Background: The mechanical properties of 3D-printed denture base resins are crucial factors for determining the quality and performance of dentures inside a patient’s mouth. Tensile strength and diametral compressive strength are two properties that could play significant roles in assessing the suitability of a material. Although they measure different aspects of material behavior, a conceptual link exists between them in terms of overall material strength and resilience. Aim: This study aims to investigate the correlation between tensile strength and diametral compressive strength after incorporating 2% ZrO2 nanoparticles (NPs) by weight into 3D-printed denture base resin. Methods: A total of 40 specimens (20 dumbbell-shaped and

... Show More
Scopus (10)
Crossref (5)
Scopus Crossref
Publication Date
Thu Jan 29 2026
Journal Name
Journal Of Interdisciplinary Mathematics
Efficient design of neural network based on modified LM training algorithm for solving nonlinear 4th order 3D-PDEs 
...Show More Authors

Authors in this work design efficient neural networks, which are based on the modified Levenberg - Marquardt (LM) training algorithms to solve non-linear fourth - order three -dimensional partial differential equations in the two kinds in the periodic and in the non-periodic - Periodic. Software reliability growth models are essential tools for monitoring and evaluating the evolution of software reliability. Software defect detection events that occur during testing and operation are often treated as counting processes in many current models. However, when working with large software systems, the error detection process should be viewed as a random process with a continuous state space, since the number of faults found during testin

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Nov 19 2020
Journal Name
Indonesian Journal Of Chemistry
Determination of Eugenol in Personal-Care Products by Dispersive Liquid-Liquid Microextraction Followed by Spectrophotometry Using <i>p</i>-Amino-<i>N,N</i>-dimethylaniline as a Derivatizing Agent
...Show More Authors

Two simple methods for the determination of eugenol were developed. The first depends on the oxidative coupling of eugenol with p-amino-N,N-dimethylaniline (PADA) in the presence of K3[Fe(CN)6]. A linear regression calibration plot for eugenol was constructed at 600 nm, within a concentration range of 0.25-2.50 μg.mL–1 and a correlation coefficient (r) value of 0.9988. The limits of detection (LOD) and quantitation (LOQ) were 0.086 and 0.284 μg.mL–1, respectively. The second method is based on the dispersive liquid-liquid microextraction of the derivatized oxidative coupling product of eugenol with PADA. Under the optimized extraction procedure, the extracted colored product was determined spectrophotometrically at 618 nm. A l

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Tue Jul 28 2026
Journal Name
Iraqi Journal Of Science
Magnetohydrodynyamic Flow for a Viscoclastic Fluid with the Generalized Oldroyd-B Model with Fractional Derivative
...Show More Authors

This paper deals with the Magnetohydrodynyamic (Mill)) flow for a viscoclastic fluid of the generalized Oldroyd-B model. The fractional calculus approach is used to establish the constitutive relationship of the non-Newtonian fluid model. Exact analytic solutions for the velocity and shear stress fields in terms of the Fox H-function are obtained by using discrete Laplace transform. The effect of different parameter that controlled the motion and shear stress equations are studied through plotting using the MATHEMATICA-8 software.

View Publication Preview PDF
Publication Date
Fri Dec 01 2023
Journal Name
Methods And Objects Of Chemical Analysis
Partial Least Squares Method for the Multicomponent Analysis of Antibacterial Mixture
...Show More Authors

This study's objective is to assess how well UV spectrophotometry can be used in conjunction with multivariate calibration based on partial least squares (PLS) regression for concurrent quantitative analysis of antibacterial mixture (Levofloxacin (LIV), Metronidazole (MET), Rifampicin (RIF) and Sulfamethoxazole (SUL)) in their artificial mixtures and pharmaceutical formulations. The experimental calibration and validation matrixes were created using 42 and 39 samples, respectively. The concentration range taken into account was 0-17 μg/mL for all components. The calibration standards' absorbance measurements were made between 210 and 350 nm, with intervals of 0.2 nm. The associated parameters were examined in order to develop the optimal c

... Show More
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref