In this study Isolated Pathogenic bacteria which causes Tonsillitis in Children with ages between 3-17 years. They are admitted to Central Children Hospital (Al-Karch) and Ebn-Albalady Hospital (Al-Rusafa). 200 cases were collected which include 120 Male and 80 Female. The result of the recent study shows that the isolation percentage was 40% from Male and 35% from Female. In this study Fifty six isolated were Identified, 20 were ?-hemolytic Streptococcus which was Streptococcus pyogenes, formed (36%) from all isolated.6 Pathogenic bacteria were ?- hemolytic Streptococcus which was Streptococcus pneumoniae formed (11%). The number of Moraxella catarrhalis bacteria was 12 formed (21%), the number of Haemophilus influenzae was 10 formed (18%).Whereas the number of Staphylococcus aureus was 8 formed (14%). The Antimicrobial Susceptility test to commonly used Antimicrobial shows that the most isolate Bacteria were sensitive to Antimicrobial ( AMC and CEP ) and Resistance to ( P and E ) with some exception. The Antimicrobial Susceptility test of Staphylococcus aureus to Oxacillin showed the predominant of Oxacillin-Sensitive S. aureus (OSSA) which form 88% whereas the percentage of Oxacillin -Resistant S. aureus (ORSA) was 12%. The effect of crude aqueous and solvent extracts of clove on selected isolated bacteria. Shows the efficiency of clove extracts which gives the biggest inhibition zones by all extracts with efficacy of methanol extract compared with the other solvents extracts. The inhibition zone was 25.2 mm fore Streptococcus pyogenes and the MIC wasMIC was 75?g/ml. 25.6 mm 75?g/ml. 24.8 mm for Streptococcus pneumoniae and For Staphylococcus aureus and MIC was 50?g/ml, whereas the inhibition zone was 22.2 mm and 22.1 mm for Moraxella catarrhalis and Haemophilus influenza respectively and the MIC was 100?g/ml.
The temperature control process of electric heating furnace (EHF) systems is a quite difficult and changeable task owing to non-linearity, time delay, time-varying parameters, and the harsh environment of the furnace. In this paper, a robust temperature control scheme for an EHF system is developed using an adaptive active disturbance rejection control (AADRC) technique with a continuous sliding-mode based component. First, a comprehensive dynamic model is established by using convection laws, in which the EHF systems can be characterized as an uncertain second order system. Second, an adaptive extended state observer (AESO) is utilized to estimate the states of the EHF system and total disturbances, in which the observer gains are updated
... Show MoreIn current article an easy and selective method is proposed for spectrophotometric estimation of metoclopramide (MCP) in pharmaceutical preparations using cloud point extraction (CPE) procedure. The method involved reaction between MCP with 1-Naphthol in alkali conditions using Triton X-114 to form a stable dark purple dye. The Beer’s law limit in the range 0.34-9 μg mL-1 of MCP with r =0.9959 (n=3) after optimization. The relative standard deviation (RSD) and percentage recoveries were 0.89 %, and (96.99–104.11%) respectively. As well, using surfactant cloud point extraction as a method to extract MCP was reinforced the extinction coefficient(ε) to 1.7333×105L/mol.cm in surfactant-rich phase. The small volume of organi
... Show MoreRoller Compacted Concrete is a type of concrete that is environmentally friendly and more economical than traditional concrete. Roller Compacted Concrete is typically used for heavy-duty and specialist constructions, such as hydraulic structures and pavements, because of its coarse surface. The main difference between RCC and conventional concrete mixtures is that RCC has a more significant proportion of fine aggregates that allow compaction and tight packing. In recent years, it has been estimated that several million tons of waste demolished material (WDM) produced each year are directed to landfills worldwide without being recycled for disposal. This review aimed to study the literature about creating a Roller-Comp
... Show MoreDyes are extensively water-soluble and toxic chemicals. The disposing of wastewater rich with such chemicals has severely impacted surface water quality (rivers and lakes). In the current study, an anionic dye, methyl orange, were extracted from wastewater fluids using bulk liquid membranes supplemented with an anionic carrier (Aliquat 336 (QCI)). Parameters including solvent type (carbon tetrachloride and chloroform), membrane stirring speed (100-250 rpm), mixing speed of both phases (50-100 rpm), The feed pH (2-12) and implemented temperature (35-60 °C) were thoroughly analyzed to determine the effect of such variables on extraction effectiveness. Furthermore, the effect of methyl orange (10-50 ppm) in the feed stage and NaOH (0
... Show MoreThis study evaluates the flexural behavior of ultra-thin (50 mm) one‑way reinforced‑concrete (RC) slabs retrofitted with near‑surface mounted (NSM) carbon‑fiber‑reinforced polymer (CFRP) rods under quasi‑static loading. T300‑grade CFRP rods (≈4 mm diameter) were bonded in pre‑cut 7 mm × 7 mm grooves using a two‑part epoxy. As a proof-of-concept experimental baseline, three simply‑supported specimens (1000 mm × 500 mm × 50 mm) were tested in a six‑point bending configuration (four applied loads + two reactions): two conventional controls and one strengthened slab. A load‑control rate of ~15 kN/min was applied; the controls were cycled twice and the strengthened slab four times. Relative to the average of
... Show MoreThe fall angle of sun rays on the surface of a photovoltaic PV panel and its temperature is negatively affecting the panel electrical energy produced and efficiency. The fall angle problem was commonly solved by using a dual-axis solar tracker that continually maintains the panel orthogonally positioning to the sun rays all day long. This leads to maximum absorption for solar radiation necessary to produce maximum amount of energy and maintain high level of electrical efficiency. To solve the PV panel temperature problem, a Water-Flow Double Glazing WFDG technique has been introduced as a new cooling tool to reduce the panel temperature. In this paper, an integration design of the water glazing system with a dual-axis tracker has been ac
... Show More