A study carried out for study effect of furfural that extracted from corn cobs by using specialized reaction system laboratory on phytopathogenic fungi: Pythium aphanidermatum, Rhizoctonia solani, Macrophomina phaseolina and Fusarium solani in addition to biocontrol fungus Trichoderma viride were isolated from infected plants and from their rhizosphere . The preparation results of different concentrations from stock solution in concentration 1% of furflural showed that The concentration was 100 ppm of furfural was inhibited the growth of P. aphanidermatum46.7 % and the was in concentration 400 ppm. while the concentration 500 ppm caused inhibition 50% and 41.1% of R. solani and F. solani respectively. Whereas the concentration 500 ppm didn’t cause inhibition of M.phaseolina. The concentration 1500 ppm caused the complete inhibition of R. solani and M.phaseolina .Also the concentration 500 ppm of furfural caused46.7 % inhibition of T.viride and complete inhibition in the concentration 1500 ppm .However complete inhibition of F. solani in the concentration 2500 ppm. The concentration 25ppm active ingredient (a. i.) of Ridomil caused 100% inhibition of P. aphanidermatum, while The concentration 20 ppm active ingredient (a. i.)of Benomyl caused 100% inhibition of R. solani and M. phaseolina, and 25ppm active ingredient (a. i.) caused 100% inhibition of F.solani. There was no effect of heat treatment (121C0) on furfural activity against the fungi .
The polymers modified Poly(vinyl chloride) differ in their tendency to photo oxidation comparing with that unmodified. It has been studied Photostability for modified Poly(vinyl chloride) chains using Schiff’s bases derivative of (5-amino-1, 3, 4-thiadiazole-2-thiol) in a manner casting of plastic chips with thickness (40) in a solvent Tetrahydrofuran. It has been determined the effectiveness Photostability of these modified polymers through the photo degradation rate constant for photostabilizer (kd) for the modified Poly (vinyl chloride). Attributed efficiency of these Poly(vinyl chloride) chips in Photostability by replace the atom Cl Poly(vinyl chloride) chains ends more stable than light stabilizer.
An idiom is a group of words whose meaning put together is different from the meaning of
individual words. English is a rich language when it comes to idioms, they represent variety. For
foreign learners, idioms are problematic because even if they know the meaning of individual
words that compose an idiom the meaning of it might be something completely different.
The present study investigates Iraqi third year college students’ recognition of idioms. To
achieve this, the researchers have conducted a test which comprises three questions. Certain
conclusions are reached here along with some suggestions and recommendations.
Researchers are interested in the issue of children abuse and they look for its cause in the past and present. Their interest is limited to identifying penal liability which is caused by children abuse away from focusing on civil liability. So, the study is going to clarify the parents' responsibility for children abuse rather than civil liability of the medic in case he wouldn’t notify the authorities about the case according to the American law rules and the attitude of Iraqi law rather than some judicial application of civil cases that were exposed to American judiciary concerning children abuse.
In this study, aromatic polyamide reverse osmosis membranes were used to remove zinc ions from electroplating wastewater. Influence of different operating conditions such as time, zinc concentration and pressure on reverse osmosis process efficiency was studied. The experimental results showed, concentration of zinc in permeate increase with increases of time from 0 to 70 min, and flux of water through membrane decline with time. While, the concentrations of zinc in permeate increase with the increase in feed zinc concentration (10–300 mg/l), flux decrease with the increment of feed concentration. The raise of pressure from 1 to 4 bar, the zinc concentration decreases and the flux increase. The highest recovery percentage was fou
... Show MoreResearchers are interested in the issue of children abuse and they look for its cause in the past and present. Their interest is limited to identifying penal liability which is caused by children abuse away from focusing on civil liability. So, the study is going to clarify the parents' responsibility for children abuse rather than civil liability of the medic in case he wouldn’t notify the authorities about the case according to the American law rules and the attitude of Iraqi law rather than some judicial application of civil cases that were exposed to American judiciary concerning children abuse.
By condensation of benzaldehyde with thiourea in absolute ethanol in the presence of glacial acetic acid as a catalyst, the Schiff base(1-benzylidenethiourea)[I] was synthesized by synthesis of 4-(3-benzylidenethioureido)-4-thioxobut-2-enoic acid compound[II] by reaction of maleic anhydride with schiff base [I] in DMF. When treating compound [II] with ammonium persulfate (NH4)2S2O8 (APS) as an ethanol initiator to obtain polymer [III], compound [III] reacted to polymer [IV] with SOCl2 in benzene. Sulfamethizole, celecoxib, salbutamol, 4-aminoantipyrine to yield polymers [V-VIII], compound [IV] reaction with different drugs. Spectral evidence established the structure of synthesized compounds: FTIR an
Thermal performance of closed wet cooling tower has been investigated experimentally and theoretically
in this work. The theoretical model based on heat and mass transfer equations and heat and mass transfer balance equations which are established for steady state case. A new small indirect cooling tower was used for conducting experiments. The cooling capacity of cooling tower is 1 kW for an inlet water temperature of 38oC, a water mass velocity 2.3 kg/m2.s and an air wet bulb temperature of 26oC. This study investigates the relationship between saturation efficiency, cooling capacity and coefficient of performance of closed wet cooling tower versus different operating parameters such wet-bulb temperature, variable air-spray water fl
Box-Wilson experimental design method was employed to optimized lead ions removal efficiency by bulk liquid membrane (BLM) method. The optimization procedure was primarily based on four impartial relevant parameters: pH of feed phase (4-6), pH of stripping phase (9-11), carrier concentration TBP (5-10) %, and initial metal concentration (60-120 ppm). maximum recovery efficiency of lead ions is 83.852% was virtually done following thirty one-of-a-kind experimental runs, as exact through 24-Central Composite Design (CCD). The best values for the aforementioned four parameters, corresponding to the most restoration efficiency were: 5, 10, 7.5% (v/v), and 90 mg/l, respectively. The obtained experimental data had been