A study carried out for study effect of furfural that extracted from corn cobs by using specialized reaction system laboratory on phytopathogenic fungi: Pythium aphanidermatum, Rhizoctonia solani, Macrophomina phaseolina and Fusarium solani in addition to biocontrol fungus Trichoderma viride were isolated from infected plants and from their rhizosphere . The preparation results of different concentrations from stock solution in concentration 1% of furflural showed that The concentration was 100 ppm of furfural was inhibited the growth of P. aphanidermatum46.7 % and the was in concentration 400 ppm. while the concentration 500 ppm caused inhibition 50% and 41.1% of R. solani and F. solani respectively. Whereas the concentration 500 ppm didn’t cause inhibition of M.phaseolina. The concentration 1500 ppm caused the complete inhibition of R. solani and M.phaseolina .Also the concentration 500 ppm of furfural caused46.7 % inhibition of T.viride and complete inhibition in the concentration 1500 ppm .However complete inhibition of F. solani in the concentration 2500 ppm. The concentration 25ppm active ingredient (a. i.) of Ridomil caused 100% inhibition of P. aphanidermatum, while The concentration 20 ppm active ingredient (a. i.)of Benomyl caused 100% inhibition of R. solani and M. phaseolina, and 25ppm active ingredient (a. i.) caused 100% inhibition of F.solani. There was no effect of heat treatment (121C0) on furfural activity against the fungi .
Plastic soil exhibits unfavorited geotechnical properties (when saturation), which causes negative defects to engineering structures. Different attempts (included various materials) were conducted to proffer solutions to such defects by experimenting in practical ways. On one hand, these attempts aimed to improve the engineering characteristics of plastic soil, and on the other hand, to use problematic waste materials as a stabilizer, like cement kiln dust, and to reduce environmental hazards. This paper explored the shrinkage, plasticity, and strength behavior of plastic soil enhanced with cement dust. The cement dust contents were 0%, 5%, 10%, 15% and 20% by dry weight of soil. An experimental series of shrinkage and p
... Show MoreThe use of essential services in modern constructions, such pipes, and ducts, became important, placing these pipes and ducts underneath the soffit of the beam. They made a ceiling sandwich, and that causes to reduce the height of the floor, so the presence of the opening in the beam saves the height of the floor. In this paper, the investigation of the beam response of reinforced concrete simply supported rectangle beams with square web openings is presented, including a number of the web openings (two, four, and eight), in addition to its use in strengthening the member at the openings (when the beam is planned before casting, internal deformation steel bar is used, and in case of the opening is existing in the b
... Show MorePolyaniline (PANI) has been prepared by the oxidation method in order to fabricate it with various concentrations of copper nanoparticles (CuNPs) which produced using the reduction method. Various techniques have characterized pure PANI and PANI doped CuNPs composites, such as fourier transform infrared spectroscopy (FT-IR), X-ray diffraction spectroscopy (XRD), field emission scanning electron microscopy (FE-SEM) and energy dispersive X-ray spectroscopy (EDS), which were provided important information about the structure and morphology of the fabricated polymer nanocomposites. The properties of dielectric permittivity (έ), dielectric loss (ἔ) and electrical conductivity (σ_AC) properties were studied at room temperature versus a range
... Show More
A descriptive study, which was using an assessment approach, was conducted for the
determination of the impact of rheumatoid arthritis and osteoarthritis patient’s functional disability
upon their life style. The study was carried out at the Rheumatology and outpatients clinics of ALKarama
Teaching Hospital, Baghdad Teaching Hospital AL-Kindey Teaching Hospital and Specialized
surgeries Teaching Hospital for the period of October 15th 2003 through May 13th 2004 in Baghdad
City. A purposive (non-probability) sample of (245) arthritis patients which was comprised (111)
rheumatoid arthritis patients and (134) osteoarthritis patients, was selected out of the early stated
settings. The questionnaire was comprised of
the use of diffrent concectration of Na and Mg ions were shown to causes in increase in the bindings at oncentration
This study aimed to investigate the influence of longitudinal steel embedded tubes located at the center of the column cross-section on the behavior of reinforced concrete (RC) columns. The experimental program consisted of 8 testing pin-ended square sectional columns of 150×150 mm, having a total height of 1400 mm, subjected to eccentric load. The considered variables were the steel square tube sizes of 25, 51 and 68 mm side dimensions and the load eccentricity (50 and 150) mm. RC columns were concealed steel tubes with hollow ratios of 3%, 12% and 20% depending on tube sizes used. The experimental results indicated an improvement in the overall behavior of eccentric columns when steel embedded tubes are used. The maximum gain in
... Show MoreAbstract
Objective(s): To evaluate the nurses` practices for children who diagnosed with febrile convulsion.
Methodology: A quantitative research, descriptive correlational design was used in this study, the study conducted on nurses who work in Al-Diwaniya Pediatrics Teaching Hospital-Iraq for Maternal and Children period from 12th September 2021 to 10th October 2022. A non- probability (convenience) sample has been applied to obtain the study goals. The study sample was (21) nurses who participate in the study. The study tool is composed of two parts: The first part is concerned with collection of nurses socio-demographic data obta
... Show MoreA long-span Prestressed Concrete Hunched Beam with Multi-Quadrilateral Opening has been developed as an alternative to steel structural elements. An experimental program was created and evaluated utilizing a single mid-span monotonic static load on simply supported beams, which included six beams with openings and the solid control beam without openings, to investigate the performance of such beams. The number and height of the quadrilateral openings are the variables to consider. According to test results, the presence of openings in the prestressed concrete hunched beam with multi-quadrilateral opening did not considerably affect their ultimate load capacity with respect to a contro
Test results of six half-scale reinforced concrete flat plates connections with an opening in the vicinity of the column are reported. The test specimens represent a portion of a slab bounded by the lines of contraflexure around the column. The tests were designed to study the effect of openings on the punching shear behavior of the slab-column connections. The test parameters were the location and the size of the openings. One specimen had no opening and the remaining five had various arrangements of openings around the column. All specimens were cast with normal density concrete of approximately 30 MPa compressive strength. The openings in the specimens were square, with the sides parallel to the sides of the column. Three sizes of ope
... Show MoreAbstract : A descriptive study was conducted out patient in Neuralgic Hospital and Teaching Baghdad Teaching Hospital from 1st July / 2004 through October 1st / 2004 . in order to assess with QOL for CVA patients , the study aimed to identifying the QOL domain of ( physical , psychological , level of independence , social and environment ) and it relation with some demographic characteristic which is related to those patients .A purposive sample of ( 50 ) CVA patients who selected from out patient clinic of hospitals . A development questionnaire was structured and is adopted of WHO quality of life qu