In the current Windows version (Vista), as in all previous versions, creating a user account without setting a password is possible. For a personal PC this might be without too much risk, although it is not recommended, even by Microsoft itself. However, for business computers it is necessary to restrict access to the computers, starting with defining a different password for every user account. For the earlier versions of Windows, a lot of resources can be found giving advice how to construct passwords of user accounts. In some extent they contain remarks concerning the suitability of their solution for Windows Vista. But all these resources are not very precise about what kind of passwords the user must use. To assess the protection of passwords, it is very useful to know how effective the widely available applications for cracking passwords. This research analyzes, in which way an attacker is able to obtain the password of a Windows Vista PC. During this research the physical access to the PC is needed. This research shows that password consists of 8 characters with small letter characters and numbers can easily be cracked if it has know usual combinations. Whereas a Dictionary Attack will probably not find unusual combinations. Adding captel letter characters will make the process harder as there are several more combinations, so it will take longer time but is still feasible. Taking into account special characters it will probably take too long time and even most Dictionary Attacks will fail. For rainbow tables the size of the table has to be considered. If it is not too big, even these small passwords cannot be cracked. For longer passwords probably the simplest ones, small letter characters and numbers, can be cracked only. In this case brute force takes too long time in most cases and a dictionary will contain only a few words this long and even the rainbow tables become too large for normal use. They can only be successful if enough limitations are known and the overall size of the table can be limited.
Aim: To find any association between specific ABO blood groups and FUT2 secretory status and COVID-19 in a sample of Iraqi dentists. Materials and Methods: For each participant, a questionnaire including demography, COVID-19 status, blood grouping, and RH factor, with chemo-sensitive symptoms was recorded. The saliva samples were collected and DNA was extracted from leukocytes. Sequencing of molecular detection of the FUT2 gene by real-time PCR and the data was done, whilst drawing the phylogenetic tree. Results: Out of 133, most of the dentists were female 61%, most were just under 35 years of age. The most participants in this study were predominantly with blood group O (40%), followed by B, A, and AB, with (90%) of them were RH+.
... Show MoreIn this research a recent developed practical modeling technique is applied for the glucose regulation system identification. By using this technique a set of mathematical models is obtained instead of single one to compensate for the loss of information caused by the optimization technique in curve fitting algorithms, the diversity of members inside the single set is interpreted in term of restricted range of its parameters, also a diagnosis criteria is developed for detecting any disorder in the glucose regulation system by investigating the influence of variation of the parameters on the response of the system, this technique is applied in this research practically for 20 cases with association of National Center for
... Show MoreThe study of the future of the international system currently appears, according to scientific data and existing facts in light of the emergence of international actors from non-states and international informal institutions, to be heading towards a non-polarity system and this trend is fueled by many variables to reduce polarity, and it is expected in the future that the international system will turn into a non-polarity.
PV connected systems are worldwide installed because it allows consumer to reduce energy consumption from the electricity grid. This paper presents the results obtained from monitoring a 1.1 kWp. The system was monitored for nine months and all the electricity generated was fed to the fifth floor for physics and renewable energy building 220 V, 50 Hz. Monthly, and daily performance parameters of the PV system are evaluated which include: average generated of system Ah per day, average system efficiency, solar irradiation around these months. The average generated kWh per day was 8 kWh/day, the average solar irradiation per day was 5.6 kWh/m2/day, the average inverter efficiency was 95%, the average modules efficien
... Show MoreThis study aims to encapsulate atenolol within floating alginate-ethylcellulose beads as an oral controlled-release delivery system using aqueous colloidal polymer dispersion (ACPD) method.To optimize drug entrapment efficiency and dissolution behavior of the prepared beads, different parameters of drug: polymer ratio, polymer mixture ratio, and gelling agent concentration were involved.The prepared beads were investigated with respect to their buoyancy, encapsulation efficiency, and dissolution behavior in the media: 0.1 N HCl (pH 1.2), acetate buffer (pH 4.6) and phosphate buffer (pH 6.8). The release kinetics and mechanism of the drug from the prepared beads was investigated.All prepared atenolol beads remained f
... Show MoreThe purpose of this study is to assess the performance of government units (Iraqi hospitals) by trying to determine the possibility of the current governmental accounting system to provide information on the performance reports of government units. In order to improve the efficiency of hospital resources management, the services provided by the hospital should be subject to performance measurement and evaluation The importance of the health sector in the provision of services, in order to raise the efficiency of the performance of services provided by government units has reached the researcher a set of conclusions, the most important
- The financial reports produced by the accounting s
Implementing smart community engagement should consider careful planning and collaboration with numerous stakeholders, including the community. The technology and program must be designed to frame its purpose and should link back to specific goals of implementing smart community engagement. Digital services do not guarantee a smart engagement between the community and the local government. This is the case for the Kubang Pasu local government where several online services have been provided in their attempt to implement the smart community concept. However, understanding on the preferences of features and requirements of existing web-based systems and the impact of these systems is lacking. Therefore, a perception study needs to be condu
... Show MoreThis paper designed a fault tolerance for soft real time distributed system (FTRTDS). This system is designed to be independently on specific mechanisms and facilities of the underlying real time distributed system. It is designed to be distributed on all the computers in the distributed system and controlled by a central unit.
Besides gathering information about a target program spontaneously, it provides information about the target operating system and the target hardware in order to diagnose the fault before occurring, so it can handle the situation before it comes on. And it provides a distributed system with the reactive capability of reconfiguring and reinitializing after the occurrence of a failure.
This paper studies the combination of fluid viscous dampers in the outrigger system to add supplementary damping into the structure, which purpose to remove the dependability of the structure to lower variable intrinsic damping. This optimizes the accuracy of the dynamic response and by providing higher level of damping, basically minimizes the wanted stiffness of the structure while at the same time optimizing the achievement.
The modal considered is a 36 storey square high rise reinforced concrete building. By constructing a discrete lumped mass model and using frequency-based response function, two systems of dampers, parallel and series systems are studied. The maximu
... Show MoreThis paper presents a complete design and implementation of a monitoring system for the operation of the three-phase induction motors. This system is built using a personal computer and two types of sensors (current, vibration) to detect some of the mechanical faults that may occur in the motor. The study and examination of several types of faults including (ball bearing and shaft misalignment faults) have been done through the extraction of fault data by using fast Fourier transform (FFT) technique. Results showed that the motor current signature analysis (MCSA) technique, and measurement of vibration technique have high possibility in the detection and diagnosis of most mechanical faults with high accuracy. Subsequently, diagnosi
... Show More