Bacterial contamination of AL-Habania reservoir was studied during the period from February 2005 to January 2006; samples were collected from four stations (AL-Warrar, AL-Theban regulator, middle of the reservoir and the fourth was towards AL-Razzaza reservoir). Coliform bacteria, faecal Coliforms, Streptococci, and faecal Streptococci were used as parameters of bacterial contamination in waters through calculating the most probable number. Highest count of Coliform bacteria (1500 cell/100ml) was recorded at AL-Razaza during August, and the lowest count was less than (300 cell/100ml) in the rest of the collection stations for all months. Fecal Coliform bacteria ranged between less than 300 cells/100ml in all stations for all months to 700 cell/100ml in AL-Warrar, AL-Razaza and in the middle of the reservoir stations during August. Streptococci bacteria count ranged between less than 300 cell/100ml to 700 cell/100ml as a highest record in AL-Razaza station during August for both. The ratio between fecal coliforms and fecal streptococci (FC: FS) was detected to determined the origin of the pollution in the reservoir depending on Geldrich statistical law in this research, the ratio ranged between (1) to (2.3).
500 samples of diarrhea stool were collected from different ages(less than 1year –upto30years) and for both genders from some patients in (Alwiya hospital for children, Al-kendi, central health public laboratory and some gavernarated labs) period(1/11/2009—1/10/2010). Kinds of bacteria and parasites agents were isolated and identified from patients with diarrhea. Nine species of gram negative bacteria from enterobacteriaceae were isolated, E. coli isolated are the higher ratio 4.8% of all, then Salmonella typhi4.6% while the lowest ratios is Citrobacterfreundii 0.4%, while the other identified species were be among the previous rotios. also Plesomonasshigelloides was isolated which concedride one of the bacterial local studies.many met
... Show MoreA microbial study conducted for a number of flour samples (30 samples) Uses in the bakery ovens in various areas of the city of Baghdad, by used the conventional methods used in laboratories in microbial tests and compared with the modern techniqueby usedof BacTrac Device 3400 equipped from SY-LAB Impedance analysersAustrian company.The results of two ways showed (The conventional way and BacTrac Device test)that the total counts of aerobic bacteria, coliform bacteria, StaphylococcusSpp. bacteria, Bacillus cereus bacteria and yeasts and molds,Most of them were within the permissible borders in the Iraqi standard for grain and its products With free samples from SalmonellaSpp. bacteria, and that the screening by BacTrac device are shorten
... Show MorePolish Academy of Sciences
Background: Listeria monocytogenes, a member of the genus Listeria, is widely distributed in agricultural environments, such as soil, manure and water. The genus of Listeria bacteria is about 15-17 species. It is a pathogenic bacterium that can cause a rare but dangerous infection called listeriosis.
Objectives: Studying the rate of salads contaminated with Listeria bacteria. and Listeria monocytogenes according to International, Arabic and Iraqi specifications and finding the correlation between commitments of restaurants to standard health conditions with contamination with these bacteria
Methods: The study included
... Show MoreThe raw material soil of Al-Sowera factory quarry (quarry soil and mixture) used for building brick industry was tested mineralogically, geochemically and geotechnically. Mineral components of soil are characterized by Clay minerals (Palygoriskite and chlorite) and nonclay minerals like calcite, quratz, feldspar, gypsum and halite. The raw material is deficient in SiO2, Al2O3, K2O, Fe2O3 and MgO, while enriched in CaO. Loss on ignition and Na2O are in suitable level and appear to be concordant with the standard. Grain size analyses show that the decreasing sand and clay, and increasing silt ratio in both quarry soil and mixture caused decreasing in strength of brick during molding and after firing. The quarry soil is characterized by high p
... Show MoreBackground: Ruptured uterus is a catastrophic event to both
mother and her fetus. Apart from maternal and fetal mortality
rates, the incidence of rupture of uterus is often taken as an
index of the standard of obstetric care.
Objective: To determine the frequency, causes, management
outcome of ruptured uterus at Al Batool maternity hospital.
Method: The study was conducted in the department of
obstetrics and gynecology at Al Batool maternity hospital
Mosul-Iraq over a period of three years from October 1st 2002
to August 30th 2005. All the cases of uterine rupture presented
during the study period were recorded and managed in the
department. Data was recorded on designed forms.
Results: Thirty nine cas
Biodiversity is one of the important biological factors in determining water quality and maintaining the
ecological balance. In this study, there are 223 species of phytoplankton were identified, and they are as
follows: 88 species of Bacillariophyta and were at 44%,70 species of Chlorophyta and they were at 29 %, 39
species of Cyanophyta and they were at 16 %, 12 species of Euglenozoa and they were at 4 %, four species of
Miozoa and they were at 3 %, and, Phylum Charophyta and Ochrophyta were only eight and two species,
respectively and both of them were at 2%. The common phytoplankton recorded in the sites studied
include Nitzschia palea, Scenedesmus quadricauda, Oscillatoria princeps, and Peridinium
This study aims to assess the removal efficiency andestablish the BOD5 and COD statisticalcorrelation of the sewage flowing in Al-Diwaniyah wastewater treatment plant in Iraq during the study period (2005-2016). The strength of the influent wastewater entering the plant varied from medium to high in strength. High concentrations of BOD5 and COD in the effluent were obtained due to the poor performance of the plant. This was observed from the BOD5 /COD ratios that did not confirm with the typical ratios for the treated sewage. To improve the performance of this plant, regression equations for BOD5 and COD removal percentages were suggested which can be used to facilitate evaluation of liquid waste and optimal control process. The equations
... Show More