Preferred Language
Articles
/
bsj-2794
Determination of Doxycycline Hyclate by Batch and Reverse Flow Injection Analysis Based on the Oxidative Coupling Reaction with 3-Methyl-2-benzothiazolinone Hydrazone hydrochloride (MBTH)

New, simple and sensitive batch and reverse FIA spectrophotometric methods for the determination of doxycycline hyclate in pure form and in pharmaceutical preparations were proposed. These methods based on oxidative coupling reaction between doxycycline hyclate and 3-methylbenzothiazolinone-2-hydrazone hydrochloride (MBTH) in the presence ammonium ceric sulfate in acidic medium, to form green water-soluble dye that is stable and has a maximum absorbance at 626 nm. A calibration graph shows that a Beer's law is obeyed over the concentration range of 1-80 and 0.5-110 ?g.mL-1 of DCH for the batch and rFIA respectively with detection limit of 0.325 ?g.mL-1 of DCH for r-FIA methods. All different chemicals and physical experimental parameters affecting the development and stability of the colored product were carefully studied. The proposed methods were successfully applied for the determination of DCH in pharmaceutical preparations.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jul 01 2022
Journal Name
Iraqi Journal Of Science
New Approach for Determination of Ciprofloxacin by Quenched Fluorescence of Analytically Interested Species Using Continuous Flow Injection Laser Diode Fluorimeter Analyser

The objective of this study was to establish an accurate, precise, sensitive, simple, fast and reliable method for the determination of ciprofloxacin hydrochloride in pure or in pharmaceutical dosage forms using Homemade instrument fluorimeter continuous flow injection analyser with solid state laser (405 nm) as a source. The method is based upon the fluorescence fluorescein sodium salt and its quenching by ciprofloxacin hydrochloride in aqueous medium. The solutions of standard and the sample were prepared in distilled water. The calibration graph was linear in the concentration range of using (10 - 100) mMol.L-1 ciprofloxacin hydrochloride (r= 0.9891) with relative standard deviation (RSD%) for 3 mMol.L-1 ciprofloxacin HCl solution is

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 30 2014
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Adsorption of Methyl Green Dye onto Bamboo in Batch and Continuous System

Adsorption techniques are widely used to remove certain classes of pollutants from waters, especially those that are not easily biodegradable. Dyes represent one of the problematic groups. The removal of methyl green from waste water using bamboo was studied in batch and continuous system. In batch system equilibrium time and adsorption isotherm was studied at different concentrations (5, 10, 15, 20, 25 and 30 ppm) and 50 mg weight of adsorbent.
Langmuir and Freundlich equations were applied for adsorption isotherm data. Langmiur equation was fitted better than Freundlich equation (R2=0.984 for Langmuir equation).The maximum percentage dye removal obtained 79.4% and adsorption capacity was 15.5 mg/g. For continuous system the breakthr

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 28 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Polymeric Membrane Sensors for the Selective Determination of Metoclopramide Hydrochloride and their Applications to Pharmaceutical Analysis

Metoclopramide (MCP) ion selective electrodes based on metoclopramide-phosphotungstic acid (MCP-PT) ion pair complex in PVC matrix membrane were constructed. The plasticizers used were tri-butyl phosphate (TBP), di-octyl phenyl phosphonate (DOPP), di-butyl phthalate (DBPH), di-octyl phthalate (DOP), di-butyl phosphate (DBP), bis 2-ethyl hexyl phosphate (BEHP). The sensors based on TBP, DOPP, DBPH and DOP display a fast, stable and linear response with slopes 59.9, 57.7, 57.4, 55.3 mV/decade respectively at pH ranged 2-6. The linear concentration range between 1.0×10-5 – 1.0×10-2 M with detection limit 3.0×10-6 and 4.0×10-6 M for electrodes using TBP, DOPP and DBPH while e

... Show More
Crossref
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Chemical Methodologies
Scopus (8)
Scopus
Publication Date
Wed Sep 02 2020
Journal Name
Indonesian Journal Of Chemistry
Synthesis, Characterization and Biological Efficacies from Some New Dinuclear Metal Complexes for Base 3-(3,4-Dihydroxy-phenyl)-2-[(2-hydroxy-3-methylperoxy-benzylidene)-amino]-2-methyl Propionic Acid

The reaction of methyldopa with o-vanillin in refluxing ethanol afforded Schiff base and characterized through physical analysis with a number of spectra also the study of biological activity. The geometry of the Schiff base was identified through using (C.H.N) analysis, Mass, 1H-NMR, FT-IR, UV-Vis spectroscopy. Metal complexes of Cr3+, Mn2+, Co2+, Ni2+, Cu2+, Zn2+, Cd2+ and Hg2+ with Schiff base have been prepared in the molar ratio 2:1 (Metal:L), (L = Schiff base ligand) except Hg2+ at molar ratio 1:1 (Hg:L). The prepared complexes were characterized by using Mass, FT-IR and UV-Vis spectral studies, on other than magnetic properties and flame atomic absorption, conductivity measurements. According to the results a dinuclear octahedral geo

... Show More
Scopus (17)
Crossref (7)
Scopus Clarivate Crossref
View Publication
Publication Date
Wed May 31 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Spectrophotometric Determination of Amiodarone Hydrochloride in Pharmaceutical Preparations

Amiodarone hydrochloride (AH) has been determined spectrophotometrically Using methyl orange (MO).  In our previous researches MO was used for determination of Mexiletine Hydrochloride [1]. The method based on complexation between MO and AH.  After shaking and diluting the complex solution with D.W, the pH was adjusted with NaOH and HCl to pH 3. The colored complex formed between AH and the reagent were transferred into separating funnels and extracted using 5.5ml CH2Cl2 and were shaken for (5 minutes).  The extracted organic layer was used for preparation of the calibration curves for spectrophotometric measurements of AH at 434nm.  The blanks were carried out in exactly the same way throughout the whole procedure.&n

... Show More
View Publication Preview PDF
Publication Date
Sun Aug 01 2021
Journal Name
Eurasian Chemical Communications
Scopus
Publication Date
Fri Jun 16 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Colorimetric Determination of Salbutamol Sulfate using Spectrophotometry-Continuous Flow Injection Technique in Pure and Pharmaceutical Forms

Simple, precise and economic batch and flow injection analysis (FIA)-spectrophotometric methods have been established for simultaneous determination of salbutamol sulfate (SLB) in bulk powder and pharmaceutical forms. Both methods based on diazotization coupling reaction of SLB with another drug compound (sulfadimidine) as a safe and green diazotization agent in alkaline medium. At 444 nm, the maximum absorption of the orange azo-dye product was observed. A thorough investigation of all chemical and physical factors was conducted for batch and FIA procedures to achieve high sensitivity. Under the optimized experimental variables, SLB obeys Beer’s law in the concentration range of 0.25-4 and 10-100 μg/mL with limits of detection o

... Show More
Scopus (1)
Crossref (2)
Scopus Crossref
Publication Date
Fri Jun 16 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Colorimetric Determination of Salbutamol Sulfate using Spectrophotometry-Continuous Flow Injection Technique in Pure and Pharmaceutical Forms

Simple, precise and economic batch and flow injection analysis (FIA)-spectrophotometric methods have been established for simultaneous determination of salbutamol sulfate (SLB) in bulk powder and pharmaceutical forms. Both methods based on diazotization coupling reaction of SLB with another drug compound (sulfadimidine) as a safe and green diazotization agent in alkaline medium. At 444 nm, the maximum absorption of the orange azo-dye product was observed. A thorough investigation of all chemical and physical factors was conducted for batch and FIA procedures to achieve high sensitivity. Under the optimized experimental variables, SLB obeys Beer’s law in the concentration range of 0.25-4 and 10-100 μg/mL with limits of detection of 0.0

... Show More
Scopus (1)
Crossref (2)
Scopus Crossref
View Publication Preview PDF
Publication Date
Fri Oct 02 2020
Journal Name
International Journal Of Pharmaceutical Research
Scopus (10)
Crossref (2)
Scopus Crossref
View Publication Preview PDF