We propose two simple, rapid, and convenient spectrophotometric methods which are described for the determination of cephalexin in bulk and its pharmaceutical preparations. They are based on the measurement of the flame atomic emission of potassium ion (in the first method) and colorimetric determination of the green colored solution at 610 nm formed after the reaction of cephalexin with potassium permanganate as an oxidant agent (in the second method) in basic medium. The working conditions of the methods are investigated and optimized. Beer's law plot shows a good correlation in the concentration range of 5-40?g ml-1. The detection limits are 2.573,2.814 ?g ml-1 for the flame emission photometric method and 1.844,2.016 ?g ml-1 for colorimetric methods for capsules and suspensions respectively.The methods are successfully applied to the determination of cephalexin in capsules and suspensions, and the obtained results are in good agreement with the label claim. No interference is observed from the commonly encountered additives and excipients.
The holmium plasma induced by a 1064-nmQ-switched Nd:YAG laser in air was investigated. This work was done theoretically and experimentally. Cowan code was used to get the emission spectra for different transition of the holmium target. In the experimental work, the evolution of the plasma was studied by acquiring spectral images at different laser pulse energies (600,650,700, 750, and 800 mJ). The repetition rates of (1Hz and 10Hz) in the UV region (200-400 nm). The results indicate that, the emission line intensities increase with increasing of the laser pulse energy and repetition rate. The strongest emission spectra appeared when the laser pulse energy is 800mJ and 10 Hz repetition rate at λ= 345.64nm, with the maximum intensi
... Show MoreSimple, cheap, sensitive, and accurate kinetic- spectrophotometric method has been developed for the determination of naringenin in pure and supplements formulations. The method is based on the formation of Prussian blue. The product dye exhibits a maximum absorbance at 707 nm. The calibration graph of naringenin was linear over the range 0.3 to 10 µg ml-1 for the fixed time method (at 15 min) with a correlation coefficient (r) and percentage linearity (r2%) were of 0.9995 and 99.90 %, respectively, while the limit of detection LOD was 0.041 µg ml-1. The method was successfully applied for the determination of naringenin in supplements with satisfac
... Show MoreGenerally the a.c. conductivity shows a power law in frequency s () where the exponent s ≤ 1. As the frequency goes to zero the conductivity become frequency independent. The a.c. conductivity was studied for the Ge1-xSex thin films to see how the selenium contents affect the permittivity and the permeability for the Ge1-x Sex. The thin films prepared by thermal evaporation at room temperature and under vacuum (~2 x10-5toor) using Edward coating unit model 306A. From the relation between ln conductivity and ln w, the effect of selenium contents in Ge1-x Sex thin films on the exponent value, the relaxation time and the maximum barrier height. An algebric fitting method for circles and circular arcs was used to find the permit
... Show MoreNuclear emission rates for nucleon-induced reactions are theoretically calculated based on the one-component exciton model that uses state density with non-Equidistance Spacing Model (non-ESM). Fair comparison is made from different state density values that assumed various degrees of approximation formulae, beside the zeroth-order formula corresponding to the ESM. Calculations were made for 96Mo nucleus subjected to (N,N) reaction at Emax=50 MeV. The results showed that the non-ESM treatment for the state density will significantly improve the emission rates calculated for various exciton configurations. Three terms might suffice a proper calculation, but the results kept changing even for ten terms. However, five terms is found to give
... Show MoreThe researches to discover useful ways to represent the agents and agent-based
systems are continuous. Unified Modeling Language (UML) is a visual modeling language
used for software and non software modeling systems. The aim of this paper is: using UML
class diagram to design treasury pharmaceuticals agent and explain its internal action. The
diagram explains the movement of the agent among other nodes to achieve user's requests
(external) after it takes them. The paper shows that it is easy to model the practical systems by
using agent UML when they are used in a complex environment.
Gas Lasers are important tools that are used in variety purposes, for their low and (cw) output power. The aim of this study was to prepare a way to calculate an optimum stimulated emission cross-section in a gas laser containing a mixture of Xenon and Neon by (30%-70%). The process was a theoretical study of each gas in separate in terms of their physical properties as an active medium. The results of these calculations are logic and more convenient than other mixtures used before
Antibiotics are essential for treating infectious diseases, but their overuse and adverse effects are raising concerns about global public health. The pervasiveness of antibiotic contamination in aquatic environments has drawn increased attention in recent years. The primary concern regarding the release of antibiotics into the environment is the potential for microorganisms to become resistant to antibiotics. This review article summarizes the analytical methods used to determine the presence of trimethoprim and metronidazole in various environmental samples. These antibiotics have traditionally been analyzed using tandem mass spectrometry or high-performance liquid chromatography coupled to mass spectrometry; fluorescence or ultrav
... Show MoreThe novel Vierordt’s approach, or simultaneous equation method, was created and validated for the concurrent determination of vincristine sulfate (VCS) and bovine serum albumin (BSA) in pure solutions utilizing UV spectrophotometry. It is simple, precise, economical, rapid, reliable, and accurate. This method depends on measuring absorbance at two wavelengths, 296 nm and 278 nm, which correspond to the λmax of VCS and BSA in deionized water, respectively. The calibration curves of VCS and BSA are linear at concentration ranges of 10–60 μg/mL and 200–1600 μg/mL, with correlation coefficient values (R2) of 1 and 0.999, respectively. The limits of detection (LOD) and quantification (LO
... Show More