Preferred Language
Articles
/
bsj-2792
Preconcentration and determination of Metformine Hydrochloride in different samples by cloud point extraction coupling with uv-visible spectrophotometry
...Show More Authors

This work was influenced the separation and preconcentration steps were carried out to determination of metformin (MET) in pharmaceutical preparations and human serum samples. Complex formation method and cloud-point extraction (CPE) coupling with UV-Visible spectrophotometry were used to investigated of study target.The results has showed the best optical characteristic for calibration curve and statistical data which were obtained under optimum conditions. The first method is based on the reaction of MET with nickel (II) in alkaline medium an absorption maximum ?)max) at 434nm. ''Beer's low'' is obeyed in the concentration range (10-100µg.ml-1) with molar absorptivity of 3.9x103 L.mol-1.cm-1.The limit of detection and quantitation values were 2.37 and7.11 µg.ml-1 respectively. The second method based on extraction of traces amounts of MET using the cloud-point extraction (CPE). This method implicated for using of a nonionic surfactant (Triton x-114) as an extraction medium which was entrap the hydrophobic complex formed between MET and nickel(ii) in basic medium as reaction system for designing the CPE procedure. The optimum conditions were similar the first method expect the amount of surfactant which was 0.5 ml. The concentrations range of calibration curve from 3.5to100 µg.ml-1 and molar absorptivity of 1.2x104 L.mol-1.cm-1. In this method was access to less of concentrations in Limit of detection and quantitation which were 0.74and 2.22 µg.ml-1 respectively. The precise (RSD %) and accuracy (recovery %) of both methods were ranged between 0.24-0.47, 97.86-98.68 respectively. The data of two methods were appeared high acceptable with standered of British Pharmacopoeia through using statistic methods (f-test and t-test), that they may be used in analysis of MET.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Mar 02 2008
Journal Name
Baghdad Science Journal
Spectrophotometric determination of Procaine penicillin in pure and pharmaceutical formulations using metol
...Show More Authors

A simple, accurate and sensitive spectrophotometric method for the determination of Procaine penicillin (PP) is described. The method is based on charge-transfer reaction of PP with metol (N-methyl-p-hydroxy aniline) in the presence of ferric sulphate to form a purple-water soluble complex ,which is stable and has a maximum absorption at 510 nm .A graph of absorbance versus concentration shows that Beer’s low is obeyed over the concentration range of 3-80 µg /ml of PP (i.e.,3-80 ppm) with a molar absorbativity of 4.945 ×103 L.mol-1.cm-1 ,Sandell sensitivity of 0.1190 µg cm-2 ,a relative error of (-1.57)-2.79 % and a standard deviation of less than 0.59 depending on the concentration of PP.The optimum conditions for full co

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Baghdad Science Journal
Determination of essential and trace elements in various vegetables using ICP-MS
...Show More Authors

Metal contents in vegetables are interesting because of issues related to food safety and ‎potential health risks. The availability of these metals in the human body ‎may perform many biochemical functions and some of them linked with various diseases at ‎high levels. The current study aimed to evaluate the concentration of various metals in ‎common local consumed vegetables using ICP-MS. The concentrations of metals in vegetables ‎of tarragon, Bay laurel, dill, Syrian mesquite, vine leaves, thymes, arugula, basil, common ‎purslane and parsley of this study were found to be in the range of, 76-778 for Al, 10-333 for B, 4-119 for ‎Ba, ‎2812‎-24645 for Ca, 0.1-0.32 for Co, 201-464 for Fe, 3661-46400 for K, 0.31–‎‎1.

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (7)
Scopus Crossref
Publication Date
Fri Apr 01 2016
Journal Name
Communications In Nonlinear Science And Numerical Simulation
Simultaneous determination of time and space-dependent coefficients in a parabolic equation
...Show More Authors

View Publication
Scopus (23)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Wed Oct 01 2025
Journal Name
Iop Conference Series: Earth And Environmental Science
Determination of Heavy Elements (Copper and Cadmium) Present in Baghdad City Dust
...Show More Authors
Abstract<p>This research investigated concentrations of the copper and cadmium in road dust gathered from varied locations in Baghdad, Iraq. Six residential areas (three from Karkh district and three from Rusafa district) were selected as a control sample. Samples were collected from the rooftops using polyethylene bagsand analyzed using an elemental determination device with a Contra 700 atomic spectrometer to determine levels of these heavy metals. The results showed significant elevations in cadmium in Al-Waziria, -0.01 and Al-Baladiyyat, -0.01, respectively (P<0.05) for each of them compared to the blank value. However, there were insignificant differences in cadmium (Cd) contamination in</p> ... Show More
View Publication
Scopus Crossref
Publication Date
Fri Nov 01 2013
Journal Name
East Asian Journal On Applied Mathematics
Free Boundary Determination in Nonlinear Diffusion
...Show More Authors
Abstract<p>Free boundary problems with nonlinear diffusion occur in various applications, such as solidification over a mould with dissimilar nonlinear thermal properties and saturated or unsaturated absorption in the soil beneath a pond. In this article, we consider a novel inverse problem where a free boundary is determined from the mass/energy specification in a well-posed one-dimensional nonlinear diffusion problem, and a stability estimate is established. The problem is recast as a nonlinear least-squares minimisation problem, which is solved numerically using the <italic>lsqnonlin</italic> routine from the MATLAB toolbox. Accurate and stable numerical solutions are achieved. For noisy data, inst</p> ... Show More
View Publication
Scopus (13)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Sun Oct 11 2026
Journal Name
Modern Sport
The reality of technological leadership in youth and sports directorates in the southern region from the point of view of employees
...Show More Authors

View Publication
Publication Date
Mon Jul 01 2024
Journal Name
Iranian Journal Of Catalysis (ijc)
Preparation, characterization, and antioxidant activity of novel metal (Mn (II), Ni (II), Pd (II), Pt (IV)) complexes: Application of Pd complex in Suzuki-Miyaura cross-coupling reaction
...Show More Authors

Publication Date
Mon Nov 01 2021
Journal Name
Transportation Geotechnics
Evaluation of permanent deformation and resilient modulus of pavement base with different gradations and percentages of clay plasticiser
...Show More Authors

View Publication
Scopus (7)
Crossref (8)
Scopus Clarivate Crossref
Publication Date
Wed Oct 02 2013
Journal Name
Journal Of Biology, Agriculture And Healthcare
The Prevalence of Aerobic Bacteria Isolated from Horses Fecal Samples
...Show More Authors

Dietary components and changes cause shifts in the gastrointestinal microbial ecology that can play a role in animal health and a wide range of diseases. However, most information about the microbial populations in the gut of horses has not been quantitative. The objective of this study was to characterize the fecal bacterial and its prevalence in healthy horses and diarrheal one in a period from September 2010 to July 2013. Out of 100 Fecal samples of horses (from farms in Al-furusyia club) in Baghdad were examined for microbial differentiation founded eighty percent of the fecal samples isolated from healthy horses. The most common pathogen found were Streptococcus spp. (33.7%), Escherichia coli (20.9%), , and Staphylococcus aureus (9.2

... Show More
Publication Date
Mon Feb 18 2019
Journal Name
Iraqi Journal Of Physics
Measurement of radon and uranium concentration in soil samples from Babylon cement plant using nuclear track detector CR-39
...Show More Authors

In this study, concentrations of radon and uranium were measured for twenty six samples of soil. The radon concentrations in soil samples measured by registrant alpha-emitting radon (222Rn) by using CR-39 track detector. The uranium concentrations in soil samples measured by using registrar fission fragments tracks in CR-39 track detector that caused by the bombardment of U with thermal neutrons from 241 Am-Be neutron source that has flux of 5 ×103n cm-2 s-1.
The concentrations values were calculated by a comparison with standard samples The results show that the radon concentrations are between (91.931-30.645Bq/m3).
The results show that also the uranium concentrat

... Show More
View Publication
Crossref (1)
Crossref