This work was influenced the separation and preconcentration steps were carried out to determination of metformin (MET) in pharmaceutical preparations and human serum samples. Complex formation method and cloud-point extraction (CPE) coupling with UV-Visible spectrophotometry were used to investigated of study target.The results has showed the best optical characteristic for calibration curve and statistical data which were obtained under optimum conditions. The first method is based on the reaction of MET with nickel (II) in alkaline medium an absorption maximum ?)max) at 434nm. ''Beer's low'' is obeyed in the concentration range (10-100µg.ml-1) with molar absorptivity of 3.9x103 L.mol-1.cm-1.The limit of detection and quantitation values were 2.37 and7.11 µg.ml-1 respectively. The second method based on extraction of traces amounts of MET using the cloud-point extraction (CPE). This method implicated for using of a nonionic surfactant (Triton x-114) as an extraction medium which was entrap the hydrophobic complex formed between MET and nickel(ii) in basic medium as reaction system for designing the CPE procedure. The optimum conditions were similar the first method expect the amount of surfactant which was 0.5 ml. The concentrations range of calibration curve from 3.5to100 µg.ml-1 and molar absorptivity of 1.2x104 L.mol-1.cm-1. In this method was access to less of concentrations in Limit of detection and quantitation which were 0.74and 2.22 µg.ml-1 respectively. The precise (RSD %) and accuracy (recovery %) of both methods were ranged between 0.24-0.47, 97.86-98.68 respectively. The data of two methods were appeared high acceptable with standered of British Pharmacopoeia through using statistic methods (f-test and t-test), that they may be used in analysis of MET.
The ion-pair formation method has been applied for the spectrophotometric determination of Cimetidine and Erythromycin ethylsuccinate, in bulk samples and in dosage form. The methods are accurate, simple, rapid, inexpensive and sensitive depending on the extraction of the formed ion-pair with brompthymol blue (BTB) as a chromogenic reagent in chloroform, use phthalate buffer of pH 5.5 and 4.0 for Cimetidine and Erythromycin ethylsuccinate respectively. The formed complexes show absorbance maxima at 427.5 nm and 414.5 nm for Cimetidine and Erythromycin ethylsuccinate respectively against reagent blank. The calibration graphs are linear in the ranges of 0.5-15 µg.mL-1 with detection limit of 0.222 µg.mL-1 for
... Show MoreMedicines comprising fosfomycin are prescribed for urinary tract infections. These drugs are available for oral use as tromethamine and calcium, while fosfomycin-sodium and disodium are given for intravenous (IV) and intramuscular (IM). Many quantitative analytical methods have been reported to estimate Fosfomycin in blood, urine, plasma, serum, and pharmaceutical dosage formulations. Some techniques were spectrophotometric, mass spectrometry, gas chromatography, high-performance liquid chromatography, and electrochemical methods. Here we perform a rapid narrative review that discusses and comparison between them of various analytical methods for the determination of Fosfomycin-containing drugs.
Objective: study aims to identify the diabetes type2 clients self management skills toward dietary pattern
, and find out the relationship between variables which are (Age, gender, educational level, duration of DM
diagnosis, and monthly income) with diabetes type 2 clients self management skills toward dietary pattern
Methodology: descriptive study was carried out through the present investigation from January 2nd
2011to September 2nd 2011 in order to achieve the objectives of the present study. A non probability
(purposive) sample, (200) cases which consists of clients who were attending Al-Nasiriyha diabetic center.
Including (118) males and (82) females. The data were collected by utilization of the study instrument
This study includes analytical methods for the determination of the drug amoxicillin trihydrate (Amox.) in some pharmaceutical preparations using Cobalt ion (Co(II)) as complexing metal. The best conditions for complexation were: the reaction time was 20 minutes, pH=1.5 and the best temperature of reaction was 70 ËšC. Benzyl alcohol was the best solvent for extraction the complex.
Keywords: Amoxicillin, Cobalt(II), Complex, Molar ratio.
Histidine was determined via measurement of total luminescence (i:e creation of chemiluminescence and insitu irradiation of released light to an acceptor fluorophore molecule to initiate fluorescence from fluorescien molecule in flat – spiral micro cell designed for this measurement . A detailed description of robust linear equation for the range of 0.002 – 0.05 mol.L-1 for a sample size of 70 µL with a correlation coefficient of 0.9879 and a coefficient of determination of 97.59% while for a quadratic model of the same concentration range was 0.9881 correlation coefficient and 97.63% coefficient of determination. Analysis of variance was conducted for both kinds of models . It indicated that their was no significa
... Show MoreBacteria could produce bacterial nanocellulose through a procedure steps: polymerization and crystallization, that occur in the cytoplasm of the bacteria, the residues of glucose polymerize to (β-1,4) lineal glucan chains that produced from bacterial cell extracellularly, these lineal glucan are converted to microfbrils, after that these microfbrils collected together to shape very pure three dimensional pored net. It could be obtained a pure cellulose that created by some M.O, from the one of the active producer organism like Acetic acid bacteria (AAB), that it is a gram -ve, motile and live in aerobic condition. The bacterial nanocellulose (BNC) have great consideration in many fields because of its flexible properties, features
... Show MoreStrong acids were determined via the precipitation reaction of loaded copper (II) ion on strong cation exchange resin which in turn reacts with potassium hyxacyano ferrate (II). The attenuation effect of formed precipitate Cu2 [Fe (CN) 6] on (0 -180o) incident LED light was measurement via homemade AYAH 5SX4-ST-5D solar CFI analyser. Optimum parameters were 0.005M.L-1 [Fe(CN)6]-4 , flow rate of 2.4 mL.min-1 , sample volume 204 μL , sample purge time of 64 seconds was chosen, and 1.6 V for light intensity. A liner calibration graph of 0.005 -0.2 M.L-1 were obtains for HCl, HNO3, HCLO4 and H2SO4, with a linearity (r2 %) 96 -97 % and L.O.D based on gradual dilution of lowest concentration in calibration graph was 37.19 μg for HCl, 64.273
... Show MoreSoil is a crucial component of environment. Total soil analysis may give information about possible enrichment of the soil with heavy metals. Heavy metals, potentially contaminate soils, may have been dumped on the ground. The concentrations of soil heavy metals (Cd, As, Pb, Cr, Ni, Zn and Cu) were measured in three zones thought to be deeply contaminated at different depths (5, 25, 50 cm) at Ibn Al-Haitham College. The highest concentration of heavy metals Pb (63.3ppm), Cr (90.7ppm), Ni (124ppm) and Cu (75.7ppm) were found in zone (A) location-1, where the highest concentration of Zn (111.7ppm) was found in zone (C). Cd and As were detected in small amounts in all zones. PH value, organic matters, carbonat
... Show More