Preferred Language
Articles
/
bsj-2791
A novel online coupling of ion selective electrode with the flow injection system for the determination of vitamin B1
...Show More Authors

A simple, fast, selective of a new flow injection analysis method coupled with potentiometric detection was used to determine vitamin B1 in pharmaceutical formulations via the prepared new selective membranes. Two electrodes were constructed for the determination of vitamin B1 based on the ion-pair vitamin B1-phosphotungestic acid (B1-PTA) in a poly (vinyl chloride) supported with a plasticized di-butyl phthalate (DBPH) and di-butyl phosphate (DBP). Applications of these ion selective electrodes for the determination of vitamin B1 in the pharmaceutical preparations for batch and flow injection systems were described. The ion selective membrane exhibited a near-Nernstian slope values 56.88 and 58.53 mV / decade, with the linear dynamic range of vitamin B1 was 5 x 10-5- 1 x 10-2 and 1 x 10-4-1 x 10-2 mol.L-1, in batch and FIA, respectively. The limit of detection was 3.5 x 10-5 and 9.5 x 10-5 mol.L-1, with the percentage linearity 98.85 and 95.22 in batch and FIA, respectively. The suggested ion selective electrode has been utilized perfection in the determination of vitamin B1 in pharmaceutical formulations using batch and flow injection system, respectively.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Engineering
Design of a PID-Lead Compensator for a Twin Rotor Aerodynamic System (TRAS)
...Show More Authors

This paper deals with a Twin Rotor Aerodynamic System (TRAS). It is a Multi-Input Multi-Output (MIMO) system with high crosscoupling between its two channels. It proposes a hybrid design procedure that combines frequency response and root locus approaches. The proposed controller is designated as PID-Lead Compensator (PIDLC); the PID controller was designed in previous work using frequency response design specifications, while the lead compensator is proposed in this paper and is designed using the root locus method. A general explicit formula for angle computations in any of the four quadrants is also given. The lead compensator is designed by shifting the dominant closed-loop poles slightly to the left in the

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Engineering
Design of a PID-Lead Compensator for a Twin Rotor Aerodynamic System (TRAS)
...Show More Authors

This paper deals with a Twin Rotor Aerodynamic System (TRAS). It is a Multi-Input Multi-Output (MIMO) system with high crosscoupling between its two channels. It proposes a hybrid design procedure that combines frequency response and root locus approaches. The proposed controller is designated as PID-Lead Compensator (PIDLC); the PID controller was designed in previous work using frequency response design specifications, while the lead compensator is proposed in this paper and is designed using the root locus method. A general explicit formula for angle computations in any of the four quadrants is also given. The lead compensator is designed by shifting the dominant closed-loop poles slightly to the left in the s-plane. This has the effect

... Show More
Publication Date
Tue Jul 13 2021
Journal Name
Journal Of Craniofacial Surgery
Comparison of Two Botulinum Toxin Injection Methods for Treatment of Excessive Gingival Display
...Show More Authors

Background: Hyperfunction of the muscles of the upper lip is considered as the most common cause of excessive gingival display (EGD). The aim of this study was to demonstrate the effectiveness of botulinum toxin (BT) injection as a conservative treatment for EGD due to muscular hyperfunction and to compare the outcome of 2 injection methods. Material and methods: This study included 40 participants who were randomly assigned into 2 groups of 20 each, The first group received 2.5IU BT injection at 1 point per side (2-points group), while the second group received a total of 5 IU of BT at 2 points per side (4-points group). The outcome variables were the reduction in the central and lateral gingival display expressed as the difference between

... Show More
View Publication
Scopus (3)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Fri Sep 01 2023
Journal Name
Iraqi Journal Of Physics
Employment of Silicon Nitride Films Prepared by DC Reactive Sputtering Technique for Ion Release Applications
...Show More Authors

In this work, silicon nitride (Si3N4) thin films were deposited on metallic substrates (aluminium and titanium sheets) by the DC reactive sputtering technique using two different silicon targets (n-type and p-type Si wafers) as well as two Ar:N2 gas mixing ratios (50:50 and 70:30). The electrical conductivity of the metallic (aluminium and titanium) substrates was measured before and after the deposition of silicon nitride thin films on both surfaces of the substrates. The results obtained from this work showed that the deposited films, in general, reduced the electrical conductivity of the substrates, and the thin films prepared from n-type silicon targets using a 50:50 mixing ratio and deposited on both

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu May 01 2025
Journal Name
Biochemical And Celuular Archives
Interleukin-38 (il-38) is a Novel Biochemical Marker in Sera of Iraqi Patients with Alzheimers Disease
...Show More Authors

ABSTRACT : Alzheimer’s disease (AD) is one of the most common inflammatory neurodegenerative diseases linked with dementia, it is characterized by the deposition of amyloid beta-peptide (Ab) in the brain. The present study aims to innovate a biochemical relationship between AD and interleukin 38 (IL-38) as an anti-inflammatory cytokine, expose novel mechanisms and concepts regarding other biochemical parameters studied previously or recently in AD patients and also examine the biochemical action of memantine (10 mg daily) on AD patients. Sixty (60) diagnosed AD patients participated in the present study and classified into four (4) groups: G3 were composed of (15) newly diagnosed males (52-78) years / without treatment, G4 composed of (15

... Show More
Publication Date
Fri Dec 01 2023
Journal Name
Baghdad Science Journal
Numerical Investigation of Physical Parameters in Cardiac Vessels as a New Medical Support Science for Complex Blood Flow Characteristics
...Show More Authors

This study proposes a mathematical approach and numerical experiment for a simple solution of cardiac blood flow to the heart's blood vessels. A mathematical model of human blood flow through arterial branches was studied and calculated using the Navier-Stokes partial differential equation with finite element analysis (FEA) approach. Furthermore, FEA is applied to the steady flow of two-dimensional viscous liquids through different geometries. The validity of the computational method is determined by comparing numerical experiments with the results of the analysis of different functions. Numerical analysis showed that the highest blood flow velocity of 1.22 cm/s occurred in the center of the vessel which tends to be laminar and is influe

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
High performance liquid chromatographic method for the determination of guaifenesin in pharmaceutical syrups and in environmental samples
...Show More Authors

A simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml res

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Nov 07 2021
Journal Name
Review Of International Geographical Education Online
Requirements of Formulating a National Strategy for Developing the Cybersecurity System in Iraq According to GCI.v4(2019) Index
...Show More Authors

The present study aims to present a proposed realistic and comprehensive cyber strategy for the Communications Directorate for the next five years (2022-2026) based on the extent of application and documentation of cybersecurity measures in the Directorate and the scientific bases formulating the strategy. The present study is significant in that it provides an accurate diagnosis of the capabilities of the cyber directorate in terms of strengths and weaknesses in its internal environment and the opportunities and threats that surround it in the external environment, based on the results of the assessment of the reality of cybersecurity according to the global Cybersecurity index, which provides a strong basis for building its strategic dire

... Show More
Preview PDF
Scopus (3)
Scopus
Publication Date
Mon Jan 01 2018
Journal Name
Journal Of Applied Engineering Science
Design and implementation of a smart home automation system based on global system for mobile communications
...Show More Authors

Recently, there has been an increasing advancement in the communications technology, and due to the increment in using the cellphone applications in the diverse aspects of life, it became possible to automate home appliances, which is the desired goal from residences worldwide, since that provides lots of comfort by knowing that their appliances are working in their highest effi ciency whenever it is required without their knowledge, and it also allows them to control the devices when they are away from home, including turning them on or off whenever required. The design and implementation of this system is carried out by using the Global System of Mobile communications (GSM) technique to control the home appliances – In this work, an ele

... Show More
View Publication
Scopus (7)
Crossref (5)
Scopus Crossref
Publication Date
Wed Oct 01 2014
Journal Name
Iosr Journal Of Mathematics
Flow through an Oscillating Rectangular Duct for Generalized Oldroyd-B Fluid with Fractional Derivatives
...Show More Authors

The analytic solution for the unsteady flow of generalized Oldroyd- B fluid on oscillating rectangular duct is studied. In the absence of the frequency of oscillations, we obtain the problem for the flow of generalized Oldroyd- B fluid in a duct of rectangular cross- section moving parallel to its length. The problem is solved by applying the double finite Fourier sine and discrete Laplace transforms. The solutions for the generalized Maxwell fluids and the ordinary Maxwell fluid appear as limiting cases of the solutions obtained here. Finally, the effect of material parameters on the velocity profile spotlighted by means of the graphical illustrations

View Publication