High-performance liquid chromatographic methods are used for the determination of water-soluble vitamins with UV-Vis. Detector. A reversed-phase high-performance liquid chromatographic has been developed for determination of water-soluble vitamins. Identification of compounds was achieved by comparing their retention times and UV spectra with those of standards solution. Separation was performed on a C18 column, using an isocratic 30% (v/v) acetonitril in dionozed water as mobile phase at pH 3.5 and flow rate 1.0m/min. The method provides low detection and quantification limits, good linearity in a large concentration interval and good precision. The detection limits ranged from 0.01 to 0.025µg/ml. The accuracy of the method was tested by measuring average recovery values ranged between 94% - 101 %. For standerd solution, and 93%-99% of honey bee samples.
The main objective of this study is to experimentally investigate the effect of the CMC polymeric drag reducer on the pressure drop occurred along the annulus of the wellbore in drilling operation and investigate the optimum polymer concentration that give the minimum pressure drop. A flow loop was designed for this purpose consist from 14 m long with transparent test section and differential pressure transmitter that allows to sense and measure the pressure losses along the test section. The results from the experimental work show that increasing in polymer concentration help to reduce the pressure drop in annulus and the optimum polymer concentration with the maximum drag reducing is 0.8 kg/m3. Also increasing in flow rate a
... Show MoreSystemic lupus erythematosus (SLE) is the prototypic multisystem autoimmune disorder with a broad spectrum of clinical presentations encompassing almost all organs and tissues. Aimes of study determination of integrin- linked kinase 1(ILK-1) and anti-smith antibody(ASAB) levels in serum of Iraqi patients with systemic lupus erythematosus, in addition, that ILK-1 may be as a diagnostic marker of SLE disease, and study the effect of systemic lupus erythematosus on renal function in these patients. This study included 100 females’ patients with systemic lupus erythematosus attending to the Rheumatology Unit in Baghdad Teaching Hospital, Medical City, (Baghdad), in addition to 30 healthy females as controller group were chosen without any chr
... Show MoreBoth type 1 diabetes and type 2 diabetes have a genetic component, with over 60 chromosomal regions related to type 1 diabetes and over 200 connected with type 2 diabetes at significant genome-wide levels. Numerous single nucleotide polymorphisms in the RETN gene and genetic variables can account for up to 70% of the variations in circulating resistin levels. The RETN polymorphism has been linked in numerous studies to obesity, insulin sensitivity, type 2 diabetes, and cerebrovascular illness. Our objective is to compare this RETN gene 3ʹ-untranslated region polymorphism in type 1 diabetes and type 2 diabetes Iraqi patients. We choose 51 type 1 diabetes and 52 type 2 diabetes patients against 50 healthy subjects (control group) to investig
... Show MoreKE Sharquie, AA Noaimi, BO Saleh, ZN Anbar…, Saudi Med J, 2009 - Cited by 13
A simple, rapid and sensitive spectrophotometric method has been proposed for the determination of La (III) using 3-hydroxy -4-(2-hydroxy-phenyl azo) naphthalene -1- sulfonic acid as a chromogenic reagent. This method is based on the formation of a red-pink colored complex, upon the reaction of La(III) with the reagent in an alkaline medium (pH= 9.50), having a maximum absorbance at 459 nm. Beer's law is valid in the concentration range 0.512 µg.ml-1 with a Sandell's sensitivity value of 0.0188 µg.cm-2 and molar absorptivity of 7376.12 L.mol-1.cm-1. The stoichiometric composition of the chelate is 1:3. The effect of the presence of different cations as interferants in the determination of La(III) under the given optimum conditions wer
... Show MoreHuge number of medical images are generated and needs for more storage capacity and bandwidth for transferring over the networks. Hybrid DWT-DCT compression algorithm is applied to compress the medical images by exploiting the features of both techniques. Discrete Wavelet Transform (DWT) coding is applied to image YCbCr color model which decompose image bands into four subbands (LL, HL, LH and HH). The LL subband is transformed into low and high frequency components using Discrete Cosine Transform (DCT) to be quantize by scalar quantization that was applied on all image bands, the quantization parameters where reduced by half for the luminance band while it is the same for the chrominance bands to preserve the image quality, the zig
... Show More