A method is developed for the determination of iron (III) in pharmaceutical preparations by coupling cloud point extraction (CPE) and UV-Vis spectrophotometry. The method is based on the reaction of Fe(III) with excess drug ciprofloxacin (CIPRO) in dilute H2SO4, forming a hydrophobic Fe(III)- CIPRO complex which can be extracted into a non-ionic surfactant Triton X-114, and iron ions are determined spectrophotometrically at absorption maximum of 437 nm. Several variables which impact on the extraction and determination of Fe (III) are optimized in order to maximize the extraction efficiency and improve the sensitivity of the method. The interferences study is also considered to check the accuracy of the procedure. The results have shown that the preconcentration factor of 71 fold leading to obtain a limit of detection of 2.67 ng mL-1 with linear calibration range of 5-150 ng mL-1 (r=0.9998) and a superb sensitivity in terms of molar absorptivity of 1.13x106 L.mol-1.cm-1 . The mean percent recovery of 99.78±0.53% and the precision (RSD %) ranged from 1.96 to 0.76 are achieved. The developed method is applied to the determination of iron in four selected pharmaceutical drugs. The experimental values agree statistically with the quoted values stated by the manufacturer’ companies.
Multi-agent systems are subfield of Artificial Intelligence that has experienced rapid growth because of its flexibility and intelligence in order to solve distributed problems. Multi-agent systems (MAS) have got interest from various researchers in different disciplines for solving sophisticated problems by dividing them into smaller tasks. These tasks can be assigned to agents as autonomous entities with their private database, which act on their environment, perceive, process, retain and recall by using multiple inputs. MAS can be defined as a network of individual agents that share knowledge and communicate with each other in order to solve a problem that is beyond the scope of a single agent. It is imperative to understand the chara
... Show MoreSolubility problem of many of effective pharmaceutical molecules are still one of the major obstacle in theformulation of such molecules. Candesartan cilexetil (CC) is angiotensin II receptor antagonist with very low water solubility and this result in low and variable bioavailability. Self- emulsifying drug delivery system (SEDDS) showed promising result in overcoming solubility problem of many drug molecules. CC was prepared as SEDDS by using novel combination of two surfactants (tween 80 and cremophore EL) and tetraglycol as cosurfactant, in addition to the use of triacetin as oil. Different tests were performed in order to confirm the stability of the final product which includes thermodynamic study, determination of self-emulsificat
... Show MoreIn the present study, the effect of new cross-section fin geometries on overall thermal/fluid performance had been investigated. The cross-section included the base original geometry of (triangular, square, circular, and elliptical pin fins) by adding exterior extra fins along the sides of the origin fins. The present extra fins include rectangular extra fin of 2 mm (height) and 4 mm (width) and triangular extra fin of 2 mm (base) 4 mm (height). The use of entropy generation minimization method (EGM) allows the combined effect of thermal resistance and pressure drop to be assessed through the simultaneous interaction with the heat sink. A general dimensionless expression for the entropy generation rate is obtained by con
... Show MoreAntibiotics are essential for treating infectious diseases, but their overuse and adverse effects are raising concerns about global public health. The pervasiveness of antibiotic contamination in aquatic environments has drawn increased attention in recent years. The primary concern regarding the release of antibiotics into the environment is the potential for microorganisms to become resistant to antibiotics. This review article summarizes the analytical methods used to determine the presence of trimethoprim and metronidazole in various environmental samples. These antibiotics have traditionally been analyzed using tandem mass spectrometry or high-performance liquid chromatography coupled to mass spectrometry; fluorescence or ultrav
... Show MoreThe corrosion protection of low carbon steel in 2.5 M HCl solution by kiwi juice was studied at different temperatures and immersion times by weight loss technique. To study the determination of the optimum conditions from statistical design in evaluation of a corrosion inhibitor, three variables, were considered as the most dominant variables. These variables are: temperature, inhibitor concentration (extracted kiwi juice) and immersion time at static conditions.
These three variables are manipulated through the experimental work using central composite rotatable Box – Wilson Experimental Design (BWED) where second order polynomial model was proposed to correlate the studied variables with the corrosion rate o
... Show MoreA group of birds were passively immunized by a transfer factor extracted from lymphocytes sensitized to adenovirus and then they were challenged by the virulent virus (adenovirus isolated from hydropericardium infected birds). The results indicatede that the groups of birds that received the transfer factor or sensitized lymphocytes were protected from having any grossly pathological changes and having a high level of anti adenovirus antibodies.
For the determination of metoclopramide hydrochloride (MCPD) in pharmaceutical formulations, a rapid and straightforward spectrophotometric method has been proposed. The method involves diazotizing the main amino group of MCPD with sodium nitrite followed by coupling reaction with reagent 1,7-Dihydroxynaphthalene (1,7-DHN) to form a stable and colored compound in alkaline medium of sodium hydroxide which showed a maximum absorbance intensity at the wavelength 578 nm. The linearity of developed method has ranged from 1.0 - 15 µg.ml-1 while the molar absorptivity 2.9867x104 l.mol-1.cm-1, RSD% was less than 1.11%. While the LOD and LOQ were 0.059 µg.ml-1
... Show MoreIn the present study twenty samples of human urine were taken
from healthy male and female with different of: ages, occupation and
place of residence. These samples were collected from the hospital to
measure the concentration of radon gas in human urine by using one
of solid state nuclear track detectors LR-115.
The results obtained of the concentrations of radon in healthy human
urine are varying from 2.12×10-3 Bq.l-1 to 4.42×10-3 Bq.l-1 and
these values are less than the allowed limits 12.3×10-3 Bq.l-1.