A potentiostatic study of the behaviour of Inconel (600) in molar sulphuric acid has been carried out over the temperature range 293-313 K. Values have been established for the potentials and current densities of the corrosion, active-passive transition, passivity and transpassive states. For corrosion, the current density (ic) and potential (Ec) have been determined from well-defined Tafel lines. The potential and current density prior to the commencement of passivity have been obtained corresponding respectively to the critical potential (Ecr( and to the current density (icr) for the active-passive transition state. The passive range was defined by the respective potentials and current densities for passive film formation and dissolution. The dissolution point was correlated with transpassive potential (Et) and current density (it). All the estimated potentials and current densities for the various states were influenced by temperature and the presence of additives in the sulphuric acid. Additives such as nitric acid, thiourea and sodium chloride lowered the corrosion current density (ic) of the alloy while hydrochloric acid enhanced the value of ic. Addition of thiourea or sodium chloride or hydrochloric acid caused a shift in the corrosion potential (Ec) to less negative values while nitric acid shifted Ec to more negative potentials. The kinetic effect of the additives have been studies. Values of activation energy (E) were considered to be apparent and some negative values of E have been obtained with certain additives for the critical and passivity processes. Such negative E values were attributed to small values of true energies of activation together with relatively large exothermic enthalpies of such processes.
Malondialdehyde (MDA) is one of many low molecular weight end-products of lipid peroxidation; it is as an index of lipid peroxidation. Uric acid is one of the endogenous oxidant-antioxidant paradoxes. The aim of this study is to evaluate the levels of serum MDA and uric acid in smokers and non smokers. This study was carried out from January to July 2012 on (30) smokers and (30) non smokers. Serum MDA level was measured spectrophotometrically using thiobarbituric acid method, whereas serum uric acid was measured using enzymatic colorimetric method. The results of the study revealed a significant increase (P<0.001) in uric acid value in smokers subject
... Show MoreAbstract
Corrosion-fatigue occurs by the combined actions of cyclic loading and corrosive environment. The effect of shot peening on cumulative corrosion-fatigue life of 1100-H12 Al alloy was investigated. Before fatigue testing, specimens were submerged in 3.5%NaCl solution for 71 days. Constant fatigue tests were performed with and without corrosive environment. Cumulative corrosion-fatigue tests were also carried out in order to determine the fatigue life before and after shot peening. The constant fatigue life was significantly reduced due to corrosive environment and the endurance fatigue limit was reduced by 13% compared with dry fatigue. In case of shot peening the cumul
... Show MoreIn this paper investigate the influences of dissolved CO2/H2S gases, crude oil velocity and temperature on the rate of corrosion of crude oil transmission pipelines of Maysan oil fields southern Iraq. The Potentiostatic corrosion test technique was conducted into two types of carbon steel pipeline (materials API 5L X60 and API 5L X80). The computer software ECE electronic corrosion engineer was used to predict the influences of CO2 partial pressure, the composition of crude oil, flow velocity of crude oil and percentage of material elements of carbon steel on the rate of corrosion. As a result, the carbon steel API 5L X80 indicates good and appropriate resistance to corrosion compared to carbon steel API
... Show MoreBackground: Esthetic treatment is the options of patient seeking orthodontic treatment. Therefore this study was conducted to measure the concentration of Aluminum, Nickel, Chromium and Iron ions released from combination of monocrysralline brackets with different arch wires immersed in artificial saliva at different duration, to evaluate the corrosion point on different parts of the orthodontic appliances before and after immersion in artificial saliva, and to evaluate the corrosion potential of each group of the orthodontic appliances. Material and methods: Eighty orthodontic sets prepared. Each set represents half fixed orthodontic appliance, from the central incisor to the first molar, for the maxillary arch, each set consisted of molar
... Show MoreThe corrosion behavior of low carbon steel in washing water of crude oil solution has been studied potentiostatically at five temperatures in the range ( 303 –343 )K, at pH ( 4 ) and at pH (4,6,7,9,11 ) at (343K)..The corrosion potential shifted to more negative values with increasing temperature and the corrosion current density increased with increasing temperature, the corrosion current density (icorr) decreased with increasing pH in the rang ( 4 – 7 ) and it increased with increasing pH in the rang ( 9 – 11 ) at ( 343 K ), while the corrosion potential generally variation with increasing pH in the rang (4-11)at(343K. From the general results for this study can be seen that thermodynamic and kinetic function were
... Show MoreWires are commonly used for the construction of orthodontic appliances and occasionally as wrought clasps and rests on partial dentures. The corrosion resistance is the most important properties of dental alloy. Corrosion process reported to cause a numerous adverse effects on both living tissue and restoration .The conditions in the mouth are very suitable for the occurrence of corrosion. The main objective of this study was to evaluate the corrosion behavior of different gauges of stainless steel wire in artificial saliva .Four gauges of dental stainless steel wire used in orthodontic and removable partial denture were used in this study 0.6mm.,0.7mm.,0 .8mm.&1.0mm.
... Show MoreAs a result of changes in the chemical properties of the Shatt al-Arab River, especially in the last decade, as well as the lack of rainfall and the effect of seawater intrusion into the Shatt al-Arab, this study was conducted to investigate the possible changes in the water pipelines like corrosive and scaling which Shatt al-Arab River is the source of water supply for domestic use. Domestic water samples were collected from 10 various locations in Basrah to study the water's tendency to be corrosive or form scales along the pipelines. The Langelier Index, Ryznar Index, Larson-Skold Index, and Saturation Index were used to determine the corrosivity potential of water based on physical and chemical parameters. Most domestic wate
... Show MoreIn vivo study was made for the coumpounds 3-(ocetyl Salicyloyl)-5,6-O-isoprpy lideneL-ascorbicocid,2,3-(acetyl Salicyloyl )-5,6-o- isopropylidene-L-ascorbic acid and 2,3,5,6(acetyl Salicyloyl )-L- ascorbic acid .And a measurement was mod for the concentration of the liberated aspirin in blood samples a fter (2,3,4,6,8,10) hours of the initial dose for the animal .The results showed that the highest concentration of aspirin was after four hours of giving the dose to the animal which is in accordance with pharmacokinetics studies