Preferred Language
Articles
/
bsj-2729
Determination of total phenol, antioxidant and antimicrobial activities of Avena sativa and Ocimum basilicum
...Show More Authors

The present study investigated the total content of phenolic compounds, antioxidant and antimicrobial activities of water extracts oat (Avena sativa) and basil (Ocimum basilicum), medicinal plants. The Folin-ciocalteu reagent assay was used to estimate the total phenolic content of plants extract. The antioxidant capacity of the plants extract was tested by ferric reducing/antioxidant power Assay (FRAP) and ferric reducing scavenging activity using DPPH method, and the antimicrobial activity was measured against [Staphylococcus epidermidis; Staphylococcus aureus; Proteus spp.; Klebsiella spp.; Escherichia coli; Candida albicans] as tester strains. The total phenolic content of Avena sativa and Ocimum basilicum extracts revealed that the mixture of plants showed higher content. The mixture of Avena sativa and Ocimum basilicum extracts showed the highest antioxidant capacity followed by Avena sativa extract and Ocimum basilicum extract with FRAP and DPPH assay. However, mixture of Avena sativa and Ocimum basilicum extracts exhibited the highest antimicrobial activity when compared to the other extracts. Thus the study revealed that the consumption of mixture herbs may enhance the immune power of our body against diseases due to free radicals.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
A sensitive spectrophotometric determination of tadalafil in pharmaceutical preparations and industrial wastewater samples
...Show More Authors

A simple, accurate, precise, rapid, economical and a high sensitive spectrophotometric method has been developed for the determination of tadalafil in pharmaceutical preparations and industrial wastewater samples, which shows a maximum absorbance at 204 nm in 1:1 ethanol-water. Beer's law was obeyed in the range of 1-7?g/ mL ,with molar absorptivity and Sandell ? s sensitivity of 0.783x105l/mol.cm and 4.97 ng/cm2respectively, relative standard deviation of the method was less than 1.7%, and accuracy (average recovery %) was 100 ± 0. 13. The limits of detection and quantitation are 0.18 and 0.54 µg .ml-1, respectively. The method was successfully applied to the determination of tadalafil in some pharmaceutical formulations

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jun 07 2015
Journal Name
Baghdad Science Journal
Flow Injection Spectrophotometric Determination of Thymol using 4-Aminoantipyrine and Copper(II) Nitrate
...Show More Authors

Flow-injection (FI) spectrophotometric method has been developed for the analysis of thymol in pharmaceutical preparations. The method is based on organic coupling reaction between thymol and 4-amino antipyrine in the presence of alkaline medium to form an intense stable red color complex with copper nitrate that has a maximum absorption at 490 nm. Optimum conditions for determination of the drug was investigated .The calibration graph was linear over the range of 5-500 µg.ml-1 of thymol . The limit of detection (LOD) and limit of quantification (LOQ) were 1.81 ?g mL-1 and 3.60 ?g mL-1 respectively .The proposed method was applied satisfactorily to the determination of thymol in mouth wash preparations. The procedure is characterized by

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Jun 06 2010
Journal Name
Baghdad Science Journal
New Method for the Determination of DL-Histidine by FIA and Chemiluminometric Detection
...Show More Authors

This paper present a simple and sensitive method for the determination of DL-Histidine using FIA-Chemiluminometric measurement resulted from oxidation of luminol molecule by hydrogen peroxide in alkaline medium in the presence of DL-Histidine. Using 70?l. sample linear plot with a coefficient of determination 95.79% for (5-60) mmol.L-1 while for a quadratic relation C.O.D = 96.44% for (5-80) mmol.L-1 and found that guadratic plot in more representative. Limit of detection was 31.93 ?g DL-Histidine (S/N = 3), repeatability of measurement was less that 5% (n=6). Positive and negative ion interferances was removed by using minicolume containing ion exchange resin located after injection valve position.

View Publication Preview PDF
Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Baghdad Science Journal
Kinetic- spectrophotometric Method for the Determination of Naringenin in Pure and Supplements Formulations
...Show More Authors

          Simple, cheap, sensitive, and accurate kinetic- spectrophotometric method has been developed for the determination of naringenin in pure and supplements formulations. The method is based on the formation of Prussian blue. The product dye exhibits a maximum absorbance at 707 nm. The calibration graph of naringenin was linear over the range 0.3 to 10 µg ml-1 for the fixed time method (at 15 min) with a correlation coefficient (r) and percentage linearity (r2%) were of 0.9995 and 99.90 %, respectively, while the limit of detection LOD was 0.041 µg ml-1. The method was successfully applied for the determination of naringenin in supplements with satisfac

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Ibn Al-haitham Jour.for Pure & Appl.sci.
Determination of Osteocalcin, Bone Alkaline Phosphatase, and Lysyl Oxidase in Iraqi Acromegalic Patients
...Show More Authors

This study was aimed to determine bone formation markers (OST and BALP) and lysyl oxidase in diabetes and non-diabetes Iraqi acromegaly patients in addition to find the relationship among these parameters. The present study conducted 60 acromegalic patients (30 diabetes & 30 non diabetes) attending National Diabetes Center / AL-Mustansiriya University/Baghdad, and 30 healthy individuals as a control group aged (35-60) years. All patients were administrated Sandostatin drug, and they were diagnosed by physician in the hospital.FBG, GH, IGF-1, OST, BALP, and LOX were determined in all groups. The results showed a highly significant rise in all parameters (GH, IGF-1, FBG, OST, BALP, and LOX values in serum of all patients when compared with n

... Show More
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Solvent Extraction And Spectrophotomteric Determination Of Cu(Ii) With Dicyclohexyl - 18- Crown-6
...Show More Authors

Liquid-Liquid Extraction of Cu(II) ion in aqueous solution by dicyclohexyl-18-crown-6 as extractant in dichloroethane was studied .The extraction efficiency was investigated by a spectrophometric method. The reagent form a coloured complex which has been a quantitatively extracted at pH 6.3. The method obeys Beer`s law over range from (2.5-22.5) ppm with the correlation coefficient of 0.9989. The molar absorptivity the stoichiometry of extracted complex is found to be 1:2. the proposed method is very sensitive and selective.

View Publication Preview PDF
Crossref
Publication Date
Tue May 01 2012
Journal Name
Iraqi Journal Of Physics
Determination the dispersion parameters and urbach tail of iron chromate doped PMMA films
...Show More Authors

Films of pure Poly (methyl methacrylate) PMMA and Iron chromate doped PMMA have been prepared using casting method. Transmission and absorptance spectra have been recorded in the wavelength range (300-900) nm, in order to calculate, single oscillator energy, dispersion energy proposed by Wemple - DiDomenico model, average oscillator strength, average oscillator wavelength. The refractive index data at infinite wavelength which was found to obey single oscillator model which was found to increase from 2.27-2.56 as the doping percentage increase. The decreasing in the optical energy gap which was found according to Tauc model were (3.74-3.63) eV , is in good agreement with that obtained by wimple-DiDomenico model. The inverse behavior comp

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 01 2023
Journal Name
Baghdad Science Journal
Batch and flow injection spectrophotometric methods for determination of Ceftazidime in pharmaceutical formulations
...Show More Authors

It is generally accepted that there are two spectrophotometric techniques for quantifying ceftazidime (CFT) in bulk medications and pharmaceutical formulations.  The methods  are described as simple, sensitive, selective, accurate and efficient techniques. The first method used an alkaline medium to convert ceftazidime to its diazonium salt, which is then combined with the 1-Naphthol (1-NPT) and 2-Naphthol (2-NPT) reagents. The azo dye that was produced brown  and red in color with absorption intensities of ƛmax 585 and 545nm respectively. Beer's law was followed in terms of concentration ranging from  (3-40) µg .ml-1 For (CFT-1-NPT) and (CFT-2-NPT), the detection limits were 1.0096 and 0.8017 µg.ml-1, respec

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Mon Mar 27 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Spectrophotometric Determination of Clonazepam in Pure and Dosage forms using Charge Transfer Reaction
...Show More Authors

A rapid, sensitive and without extraction spectrophotometric method for determination of clonazepam (CLO) in pure and pharmaceutical dosage forms has been described. The proposed method was simply depended on charge transfer reaction between reduced CLO (n-donor) and metol (N-methyl-p-aminophenol sulfate) as a chromogenic reagent (π- acceptor). The reduced drug, with zinc and concentrated hydrochloric acid, produced a purple colored soluble charge-transfer complex with metol in the presence of sodium metaperiodate in neutral medium, which has been measured at λmax 532 nm. All the variables which affected the developed and the stability of the colored product such as concentration of reagent and oxidant, temperature and time of rea

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Wed Nov 01 2023
Journal Name
Ecological Engineering & Environmental Technology
Synthesis of Mn-Co-Ni Composite Electrode by Anodic and Cathodic Electrodeposition for Indirect Electro-oxidation of Phenol – Optimization of the Removal by Response Surface Methodology
...Show More Authors

In the present work, Response Surface Methodology (RSM) was utilized to optimize process variables and find the best circumstances for indirect electrochemical oxidation of mimicked wastewater to remove phenol contaminants using prepared ternary composite electrode. The electrodeposition process is used for the synthesis of a ternary composite electrode of Mn, Co, and Ni oxides. The selected concentrations of metal salts of these elements were 0.05, 0.1, and 1.5 M, with constant molar ratio, current density, and electrolysis time of 1:1:1, 25 mA/cm2, and 2 h. Interestedly, the gathered Mn-Co-Ni oxides were deposited at both the anode and cathode. X-ray diffraction (XRD) and scanning electron microscopy (SEM) facilitated the qualitative char

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (3)
Scopus Crossref