In this study, ceramic purifier (CP) was produced from a mixture of Iraqi raw materials. This ceramic mixture was prepared using Bentonite as a Clay, Porcelanite as a Silica, and Limestone as a flux. The produced ceramic filter was formed by semi-dry compressing method and was fired at 1200 C?. Physical properties of the produced CP were measured. A hydraulic test rig was constructed to study the hydraulic conductivity of the produced CP. The average hydraulic conductivity of the produced CP was 55 times that of commercial types of ceramic filters. The mineral composition of the produced ceramics was found by X-Ray tests. Tests results showed that all of the produced ceramics filters composed mainly of low Cristobalte and Tridoymite in addition to some of other minerals. Both of the raw and the water purified by produced ceramic were tested for a number of water quality parameters. that the ceramic disc purifier could remove, as an average percentages of removal, 99.98% of turbidity, 78.86% of the electrical conductivity , 81.61% of the total dissolved solids, 73.45% of Ca++, 49.69% of Na+, 55.63% of NO3-, 37.54% of HCO3- . The results showed that CP has excellent adsorption ability for solutes of seven heavy metals, Mn, Fe, Pb, Cd, Co, Cu and Zn, at concentrations of 1 mg/leach and 10 mg/l each. The adsorption capacities of each filter to adsorb seven heavy metals were computed according to Langmuir model and Freundlich models. The results showed variety in adsorption capacities for each heavy metal.
: Partial purification of phosphoenolpyruvate carboxykinase (PEPCK) from type 2 diabetic patients sera take place using some purification steps such as participation with ammonium sulphate (55-80%) and filtered through dialysis, then ion exchange chromatography by DEAE sepharose anion column, gel filtration chromatography by sephadex G-100 column. In ion exchange step, there are four peak are obtained, the highest enzyme activity obtained by (0.4 M Nacl) with purification fold (2.18), yield (44.3) of enzyme and specific activity (13.5) mg/ng, which obtained a single peak by gel filtration chromatography, the degree of purification (5.34) fold, yield of enzyme (20%) with specific activity (33.109mg/ng). The purified enzyme had an optimum tem
... Show MoreBackground: Type two diabetic patients have higher risk of cardiovascular and periodontal disease. Furthermore, patients with more severe periodontal disease have higher incidence of cardiovascular disease. This study aimed to assess the association between periodontal health status and the risk of vascular disease in type 2 diabetic patients. Materials and Methods: One hundred type 2 diabetes mellitus patients and fifty apparently healthy males were enrolled in this study. Oral examinations conducted were; plaque Index, calculus index, gingival index, probing pocket depth, and clinical attachment level. For the assessment of vascular risk, arterial stiffness index was used. Results: According to arterial stiffness index, type 2 diabetic p
... Show MoreThe research’s main goal is to investigate the effects of using magnetic water in concrete mixes with regard to various mechanical properties such as compressive, flexural, and splitting tensile strength. The concrete mix investigated was designed to attain a specified cylinder compressive strength (30 MPa), with mix proportions of 1:1.8:2.68 cement to sand to crushed aggregate. The cement content was about 380 kg/m3, with a w/c ratio equal to 0.54, sand content of about 685 kg/m3, and gravel content of about 1,020 kg/m3. Magnetic water was prepared via passing ordinary water throughout a magnetic field with a magnetic intensity of 9,000 Gauss. The strength test
Source, sedimentation, coagulation, flocculation, filter, and tank are parts of a water treatment plant. As a result, some issues threaten the process and affect the drinking water quality, which is required to provide clean drinking water according to special standards and international and local specifications, determined by laboratory results from physical, chemical, and biological tests. In order to keep the water safe for drinking, it is necessary to analyze the risks and assess the pollution that occurs in every part of the plant. The method is carried out in a common way, which is monitoring through laboratory tests, and it is among the standards of the global and local health regulators
In the current study, a novel approach for separating ethanol-water mixture by microbubble distillation technology was investigated. Traditional distillation processes require large amounts of energy to raise the liquid to its boiling point to effect removal of volatile components. The concept of microbubble distillation by comparison is to heat the gas phase rather than the liquid phase to achieve separation. The removal of ethanol from the thermally sensitive fermentation broths was taken as a case of study. Consequently the results were then compared with those which could be obtained under equilibrium conditions expected in an “ideal” distillation unit. Microbubble distillation has achieved vapour compositions higher than th
... Show MoreSource, sedimentation, coagulation, flocculation, filter, and tank are parts of a water treatment plant. As a result, some issues threaten the process and affect the drinking water quality, which is required to provide clean drinking water according to special standards and international and local specifications, determined by laboratory results from physical, chemical, and biological tests. In order to keep the water safe for drinking, it is necessary to analyze the risks and assess the pollution that occurs in every part of the plant. The method is carried out in a common way, which is monitoring through laboratory tests, and it is among the standards of the global and local health regulators
The significant shortage of usable water resources necessitated the creation of safe and non-polluting ways to sterilize water and rehabilitate it for use. The aim of the present study was to examine the ability of using a gliding arc discharge to inactivate bacteria in water. Three types of Bacteria satisfactory were used to pollute water which are Escherichia coli (Gram-negative), Staphylococcus aurous (Gram-positive) and salmonella (Gram-negative). A DC power supply 12V at 100 Hz frequency was employed to produce plasma. pH of water is measured gradually during the plasma treatment process. Contaminated water treated by gliding arc discharge at steadying the gas flow rate (1.5 l/mi
Irrigation scheduling techniques is one of the suggested solutions for water scarcity problem. The study aims to show the possibility of using practical and applicable irrigation scheduling program which was designed by Water Resources Department at the University of Baghdad by using Spreadsheet Formulas for Microsoft Excel program, version 2007, with some modification to generalize it and made it applicable to various climatic zone and different soil types, as a salvation for the shortage of irrigation water inside the irrigation projects. Irrigation projects which incidence of Tigris River basin will be taken as an applicable example. This program was based on water budgeting and programmed depending on scientific concepts which facili
... Show MoreThe present work describes the adsorption of Ba2+ and Mg2+ions from aqueous solutions by activated alumina in single and binary system using batch adsorption. The effect of different parameters such as amount of alumina, concentration of metal ions, pH of solution, contact time and agitation speed on the adsorption process was studied. The optimum adsorbent dosage was found to be 0.5 g and 1.5 g for removal of Ba2+ and Mg2+, respectively. The optimum pH, contact time and agitation speed, were found to be pH 6, 2h and 300 rpm, respectively, for removal of both metal ions. The equilibrium data were analyzed by Langmuir and Freundlich isotherm models and the data fitted well to both isotherm modes as indicated by higher correlation of deter
... Show More