Preferred Language
Articles
/
bsj-2683
Study affects Pulse Parameters versus cavity length for both Dispersion Regimes in FM mode locked.: Bushra.R.Mhdi|Gaillan H.Abdullah|Mohand M.Azzawi|Nahla.A.Hessin|Basher.R.Mhdi
...Show More Authors

To demonstrate the effect of changing cavity length for FM mode locked on pulse parameters and make comparison for both dispersion regime , a plot for each pulse parameter as Lr function are presented for normal and anomalous dispersion regimes . The analysis is based on the theoretical study and the results of numerical simulation using MATLAB. The effect of both normal and anomalous dispersion regimes on output pulses is investigate Fiber length effects on pulse parameters are investigated by driving the modulator into different values. A numerical solution for model equations using fourth-fifth order, Runge-Kutta method is performed through MATLAB 7.0 program. Fiber length effect on pulse parameters is investigated by driving the modulator into different values of lengths. Result shows that, the output pulse width equals to ?= 501ns anomalous regime and ?=518ns in normal regime.

Crossref
View Publication
Publication Date
Sun Mar 29 2020
Journal Name
Energy & Fuels
Stable Dispersion of Coal Fines during Hydraulic Fracturing Flowback in Coal Seam Gas Reservoirs—An Experimental Study
...Show More Authors

In subterranean coal seam gas (CSG) reservoirs, massive amounts of small-sized coal fines are released during the production and development stages, especially during hydraulic fracturing stimulation. These coal fines inevitably cause mechanical pump failure and permeability damage due to aggregation and subsequent pore-throat blockage. This aggregation behavior is thus of key importance in CSG production and needs to be minimized. Consequently, such coal fines dispersions need to be stabilized, which can be achieved by the formulation of improved fracturing fluids. Here, we thus systematically investigated the effectiveness of two additives (ethanol, 0.5 wt % and SDBS, 0.001 and 0.01 wt %) on dispersion stability for a wide range of condit

... Show More
Preview PDF
Scopus (95)
Crossref (92)
Scopus Clarivate Crossref
Publication Date
Fri Sep 17 2021
Journal Name
Al-kindy College Medical Journal
Single Layer Extra-Mucosal Versus Double Layer Intestinal Anastomosis for Colostomy Closure: A Prospective Comparative Study
...Show More Authors

Background: The main objective was to compare the outcome of single layer interrupted extra-mucosal sutures with that of double layer suturing in the closure of colostomies.

Subjects and Methods: Sixty-seven patients with closure colostomy were assigned in a prospective randomized fashion into either single layer extra-mucosal anastomosis (Group A) or double layer anastomosis (Group B). Primary outcome measures included mean time taken for anastomosis, immediate postoperative complications, and mean duration of hospital stay. Secondary outcome measures assessed the postoperative return of bowel function, and the overall mean cost. Chi-square test and student t-test did the statistical analysis..

Resu

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Apr 02 2018
Journal Name
Al-nahrain Journal For Engineering Sciences (njes)
Output Feedback Adaptive Sliding Mode Control Design for a Plate Heat Exchanger
...Show More Authors

The heat exchanger is a device used to transfer heat energy between two fluids, hot and cold. In this work, an output feedback adaptive sliding mode controller is designed to control the temperature of the outlet cold water for plate heat exchanger. The measurement of the outlet cold temperature is the only information required. Hence, a sliding mode differentiator was designed to estimate the time derivative of outlet hot water temperature, which it is needed for constructing a sliding variable. The discontinuous gain value of the sliding mode controller is adapted according to a certain adaptation law. Two constraints which imposed on the volumetric flow rate of outlet cold (control input) were considered within the rules of the proposed

... Show More
Preview PDF
Publication Date
Mon Apr 02 2018
Journal Name
Al-nahrain Journal For Engineering Sciences (njes)
Output Feedback Adaptive Sliding Mode Control Design for a Plate Heat Exchanger
...Show More Authors

The heat exchanger is a device used to transfer heat energy between two fluids, hot and cold. In this work, an output feedback adaptive sliding mode controller is designed to control the temperature of the outlet cold water for plate heat exchanger. The measurement of the outlet cold temperature is the only information required. Hence, a sliding mode differentiator was designed to estimate the time derivative of outlet hot water temperature, which it is needed for constructing a sliding variable. The discontinuous gain value of the sliding mode controller is adapted according to a certain adaptation law. Two constraints which imposed on the volumetric flow rate of outlet cold (control input) were considered within the rules of the proposed

... Show More
Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
Simole matimatical technique in leaser cavity design and manufacturing
...Show More Authors

In this research design was treated gap laser mathematically and practically Bashaddam model Raasi simple and new and we have found that there is a good match in the practical and theoretical results

View Publication Preview PDF
Publication Date
Wed Sep 09 2020
Journal Name
Optics Express
Monolithically integrated membrane-in-the-middle cavity optomechanical systems
...Show More Authors

We describe curved-mirror Fabry-Perot cavities with embedded silicon nitride membranes, fabricated using a monolithic surface-micromachining process. The presence of the suspended membranes was confirmed by confocal microscopy, and their properties were verified through optical studies and thermomechanical calibration of mechanical/vibrational noise spectra measured at room temperature and atmospheric pressure. The cavities exhibit reflectance-limited finesse (F ∼ 103) and wavelength-scale mode volumes (VM ∼ 10·λ3). The short cavity length (L ∼ 2·

... Show More
View Publication
Scopus (9)
Crossref (9)
Scopus Crossref
Publication Date
Sat Jun 30 2007
Journal Name
Al-kindy College Medical Journal
Early Laparoscopic Versus Open Cholecystectomy for Acute Cholecystitis
...Show More Authors

Background: Acute cholecystitis is common surgical
problem, which was treated previously by conservative
treatment .Later early open has been introduced as an
alternative to interval for treatment of acute cholecystitis.
Early open was found to be a safe, successful with
comparable postoperative complication rate. With the
advent of laparoscopy laparoscopic have been used for
chronic cholecystitis and became the first line of
treatment. New reports have shown that laparoscopic can
be used as an alternative to open for surgical treatment of
acute cholecystitis.
Objectives: to compare the success, safety of early
laparoscopic versus early open as a primary treatment of
acute cholecystitis.
Methods:

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 15 2021
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Comparative Study of Liver Function and Rh Blood Group between both Physiological and Pathological Neonatal Jaundice
...Show More Authors

Abstract

Backgrounds: Jaundice occurs in most newborn due to increased bilirubin concentration. Jaundice is observed during the first week after birth in approximately 60% of term neonates. A high level of bilirubin is neurotoxic and may cause neonatal kernicterus, auditory neuropathy or death.

Objectives: to compare the Rh group compatibility, serum bilirubin (total and direct), serum albumin and several liver enzymes between physiological and pathological neonatal jaundice

Materials and Methods: A cross sectional study for one hundred neonates with jaundice divided into group 1: 50 newborns with physiological jaundice, Group 2: 50 newborns with

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sat Aug 20 2022
Journal Name
International Journal Of Health Sciences
Study the efficacy of intralesional pentoxifylline versus triamcinolone acetonide in keloid scars patients
...Show More Authors

Keloids are prevalent fibro-proliferative tumors, and treating them is still a challenge although intralesional injections of triamcinolone acetonide (TAC) are effective, they have frequently linked adverse effects. Pentoxifylline (PTX) is an anti-fibrotic and anti-inflammatory, and vasodilator. It has not yet been tested for intralesional injection in keloids. The aim of the study is to study the efficacy of intralesional pentoxifylline versus triamcinolone acetonide in keloid scars of 40 patients. In this study, 40 patients with keloid scars regardless of the cause of keloid born, 20 patients have injected with intralesional triamcinolone acetonide, and 20 patients with intralesional pentoxifylline every two weeks until the lesi

... Show More
View Publication
Crossref
Publication Date
Thu Feb 01 2024
Journal Name
Baghdad Science Journal
Comparative Study of Gamma- Ray Shielding Parameters for Different Epoxy Composites
...Show More Authors

In the current work various types of epoxy composites were added to concrete to enhance its effectiveness as a gamma- ray shield. Four epoxy samples of (E/clay/B4C) S1, (E/Mag/B4C) S2, (EPIL) S3 and (Ep) S4 were used in a comparative study of gamma radiation attenuation properties of these shields that calculating using Mont Carlo code (MCNP-5). Adopting Win X-com software and Artificial Neural Network (ANN), µ/ρ revealed great compliance with MCNP-5. By applying (µ/ρ) output for gamma at different energies, HVL, TVL and MFP have been also estimated. ANN technique was simulated to estimate (µ/ρ) and dose rates. According to the results, µ/ρ of all epoxy samples scored higher than standard concrete. Both S2 and S3 samples having h

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Crossref