Preferred Language
Articles
/
bsj-2683
Study affects Pulse Parameters versus cavity length for both Dispersion Regimes in FM mode locked.: Bushra.R.Mhdi|Gaillan H.Abdullah|Mohand M.Azzawi|Nahla.A.Hessin|Basher.R.Mhdi
...Show More Authors

To demonstrate the effect of changing cavity length for FM mode locked on pulse parameters and make comparison for both dispersion regime , a plot for each pulse parameter as Lr function are presented for normal and anomalous dispersion regimes . The analysis is based on the theoretical study and the results of numerical simulation using MATLAB. The effect of both normal and anomalous dispersion regimes on output pulses is investigate Fiber length effects on pulse parameters are investigated by driving the modulator into different values. A numerical solution for model equations using fourth-fifth order, Runge-Kutta method is performed through MATLAB 7.0 program. Fiber length effect on pulse parameters is investigated by driving the modulator into different values of lengths. Result shows that, the output pulse width equals to ?= 501ns anomalous regime and ?=518ns in normal regime.

Crossref
View Publication
Publication Date
Fri Mar 31 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Micro encapsulation of Naproxen By Complex Coacervation and Aqueous Colloid Dispersion Part ( 1 )
...Show More Authors

Naproxen is a non steroidal anti inflammatory and antipyretic drug which has local irritation effect  on  the  stomach, and  unpleasant taste,  besides bad   flowability and light sensitivity .The drug was prepared as microcapsules by complex coacervation method using acacia-gelatin coating materials , and aqueous colloid polymer dispersion method ( ACPD ), using ethyl cellulose and sodium alginate coating materials . The results indicated that microcapsules prepared by 2:1  core:wall ratio is the best for both methods, with an average encapsulation efficiency (75%) and avarege yield (90%) .

Moreover the drug release was affected mainly by core : ratio ,pH enviroment and method of microenca

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 01 2020
Journal Name
Baghdad Science Journal
Seasonal variation and correlation between the physical, chemical and microbiological parameters of Nile water in selected area in Egypt (Case study): physical, chemical and microbiological parameters of Nile water
...Show More Authors

Fresh water resources in terms of water quality is a crucial issue worldwide. In Egypt, the Nile River is the main source of fresh water in the country and monitoring its water quality is a major task on governments and research levels. In the present case study, the physical, chemical and algal distribution in Nile River was monitored over two seasons (winter and summer) in 2019. The aims of the study were to check the seasonal variation among the different water parameters and also to check the correlations between those parameters. Water samples were collected from the Nile in Cairo governorate in EGYPT. The different physiochemical and microbiological properties in water samples were assessed. The studied parameters were included: te

... Show More
View Publication Preview PDF
Scopus (18)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Mon Jun 30 2014
Journal Name
Al-kindy College Medical Journal
Ultrasound assessment of normal splenic length and spleen to left kidney ratio in sample of Iraqi population
...Show More Authors

Background: Spleen is a hemopoietic organ which is capable of supporting elements of different systems. It is affected by several groups of diseases; inflammatory, hematopoietic, reticuloendothelial proliferation, portal hypertension and storage diseases. Ultrasound (US) may detect mild splenomegaly before it is clinically palpable. Knowledge of the normal range of spleen size in the population being examined is a prerequisite. Racial differences in splenic length could result in incorrect interpretation of splenic measurements and such differences would make it difficult to standardize expected splenic length and to determine non- palpable splenic enlargement.Objectives: To measure the normal values of splenic lengthin Iraqi subjects an

... Show More
View Publication Preview PDF
Publication Date
Wed Feb 12 2020
Journal Name
Annals Of Tropical Medicine And Public Health
Microdebrider-assisted turbinoplasty versus submucosal diathermy in treatment of inferior turbinate hypertrophy
...Show More Authors

The surgical treatment of inferior turbinate hypertrophy (ITH) is challenging. Submucosal diathermy (SMD) is a well-known surgical procedure used for the treatment of ITH, microdebrider-assisted rhinoplasty (MAT) is relatively a newer technique used in the management of ITH. To evaluate the effect of MAT on inferior turbinate size and nasal airway patency in patients with bilateral ITH in comparison to SMD. Seventy-one patients presented with nasal obstruction due to bilateral ITH were allocated into two groups, group a (35 patients) were subjected to SMD and 36 patients in group B were subjected to MAT. All the patients had been sent to CT scan pre-operatively and at the third postoperative month to measure the cross-sectional areas

... Show More
Scopus
Publication Date
Sat Mar 14 2020
Journal Name
Medico-legal Update,
Fasting Versus Non-Fasting in Assessing Lipid Profile and Complete Blood Picture
...Show More Authors

Scopus (2)
Scopus
Publication Date
Fri Feb 25 2022
Journal Name
Open Access Macedonian Journal Of Medical Sciences
Prospective Comparative Study of Fixing Displaced Transverse Patellar Fracture by Tension Band Wiring Versus Cannulated Screws with Wiring
...Show More Authors

BACKGROUND: Transverse fractures of the patella are important fractures with a wide variety of subtypes, the common incidence in the age group of 20–50 years. Surgical interference aims to achieve a perfect alignment of the joint surface, in addition to rigid fixation of the fracture for early re-habitation and early movement to retain the extensor mechanism of the knee joint. AIM: The aim of this study was to compare the radiological and functional outcomes of the displaced transverse patella fracture in adult patients treated by ORIF using tension band wiring versus cannulated screws with wiring. METHODS: A prospective analytic comparative study was conducted in Al-Kindy Teaching Hospital/Baghdad/Iraq for 18 months from Apr

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sat Mar 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Selection of Suitable Drilling Parameters for obtaining high Rate of Penetration in Majnoon Oilfield
...Show More Authors

Several directional wells have been drilled in Majnoon oilfield at wide variation in drilling time due to different drilling parameters applied for each well. This technical paper shows the importance of proper selection of the bit, Mud type, applied weight on Bit (WOB), Revolution per minute (RPM), and flow rate based on the previous wells drilled. Utilizing the data during drilling each section for directional wells that's significantly could improve drilling efficiency presented at a high rate of penetration (ROP). Based on the extensive study of three directional wells of 35 degree inclination (MJ-51, MJ-52, and MJ-54) found that the applied drilling parameters for MJ-54 and the bit type within associated drilling parameters to drill

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 02 2017
Journal Name
Al-khwarizmi Engineering Journal
Mathematical Modeling for the Clarifier Units and Turbidity Parameters in AL-KARAMA Treatment Plant
...Show More Authors

The high cost of chemical analysis of water has necessitated various researches into finding alternative method of determining portable water quality. This paper is aimed at modelling the turbidity value as a water quality parameter. Mathematical models for turbidity removal were developed based on the relationships between water turbidity and other water criteria. Results showed that the turbidity of water is the cumulative effect of the individual parameters/factors affecting the system. A model equation for the evaluation and prediction of a clarifier’s performance was developed:

Model: T = T0(-1.36729 + 0.037101∙10λpH + 0.048928t + 0.00741387∙alk)

The developed model will aid the predictiv

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 02 2018
Journal Name
Iraqi Journal Of Physics
Optical emission spectroscopy for studying the exploding copper wire plasma parameters in distilled water
...Show More Authors

This work aims to study the exploding copper wire plasma parameters by optical emission spectroscopy. The emission spectra of the copper plasma have been recorded and analyzed The plasma electron temperature (Te), was calculated by Boltzmann plot, and the electron density (ne) calculated by using Stark broadening method for different copper wire diameter (0.18, 0.24 and 0.3 mm) and current
of 75A in distilled water. The hydrogen (Hα line) 656.279 nm was used to calculate the electron density for different wire diameters by Stark broadening. It was found that the electron density ne decrease from 22.4×1016 cm-3 to 17×1016 cm-3 with increasing wire diameter from 0.18 mm to 0.3 mm while the electron temperatures increase from 0.741 to

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Aip Conference Proceedings
Sliding mode control based on high-order extended state observer for flexible joint robot under time-varying disturbance
...Show More Authors

Abstract. In this paper, a high order extended state observer (HOESO) based a sliding mode control (SMC) is proposed for a flexible joint robot (FJR) system in the presence of time varying external disturbance. A composite controller is integrated the merits of both HOESO and SMC to enhance the tracking performance of FJR system under the time varying and fast lumped disturbance. First, the HOESO estimator is constructed based on only one measured state to precisely estimate unknown system states and lumped disturbance with its high order derivatives in the FJR system. Second, the SMC scheme is designed based on such accurate estimations to govern the nominal FJR system by well compensating the estimation errors in the states and the lumped

... Show More
View Publication
Scopus (7)
Crossref (3)
Scopus Crossref