Preferred Language
Articles
/
bsj-2619
Theoretical Study of Thermal Cracking For Acenaphthylene Molecule
...Show More Authors

Density Functional Theory (DFT) calculations were carried out to study the thermal cracking for acenaphthylene molecule to estimate the bond energies for breaking C8b-C5a , C5a-C5 , C5-C4 , and C5-H5 bonds as well as the activation energies. It was found that for C8b-C5a , C5-C4 , and C5-H5 reactions it is often possible to identify one pathway for bond breakage through the singlet or triplet states. The atomic charges , dipole moment and nuclear – nuclear repulsion energy supported the breakage bond .Also, it was found that the activation energy value for C5-H5 bond breakage is lower than that required for C8b-C5a , C5a-C5 , C5-C4 bonds which refer to C5-H5 bond in acenaphthylene molecule are weaker than C8b-C5a , C5a-C5 , C5-C4 bonds .It is reasonable to presume that C5-H5 bonds are broken first when a acenaphthylene molecule is exposed to thermal cracking. It seems that the characteristic planarity for the polyaromatic hydrocarbons is an important factor to acquire the molecule structure of the required stability along the reaction path . The trends in the bond energies and the configuration structures are discussed .

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Feb 01 2023
Journal Name
Baghdad Science Journal
Spectrophotometric Method Combined with HPLC for Bisphenol F Determination in Plastic Bottled Water and Thermal Paper
...Show More Authors

Based on the diazotization-coupling reaction, a new, simple, and sensitive spectrophotometric method for determining of a trace amount of (BPF) is presented in this paper. Diazotized metoclopramide reagent react with bisphenol F produces an orange azo-compound with a maximum absorbance at 461 nm in alkaline solution. The experimental parameters were optimized such as type of alkaline medium, concentration of NaOH, diazotized metoclopramide amount, order additions, reaction time, temperature, and effect of organic solvents to achieve the optimal performance for the proposed method. The absorbance increased linearly with increasing bisphenol F concentration in the range of 0.5-10 μg mL-1 under ideal conditions, with a correlati

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Sep 01 2019
Journal Name
Gazi University Journal Of Science
Reliable Iterative Methods for Solving Convective Straight and Radial Fins with Temperature-Dependent Thermal Conductivity Problems
...Show More Authors

In our article, three iterative methods are performed to solve the nonlinear differential equations that represent the straight and radial fins affected by thermal conductivity. The iterative methods are the Daftardar-Jafari method namely (DJM), Temimi-Ansari method namely (TAM) and Banach contraction method namely (BCM) to get the approximate solutions. For comparison purposes, the numerical solutions were further achieved by using the fourth Runge-Kutta (RK4) method, Euler method and previous analytical methods that available in the literature. Moreover, the convergence of the proposed methods was discussed and proved. In addition, the maximum error remainder values are also evaluated which indicates that the propo

... Show More
View Publication
Crossref (6)
Crossref
Publication Date
Tue Nov 01 2022
Journal Name
Computers And Electronics In Agriculture
A novel heat-pulse probe for measuring soil thermal conductivity: Field test under different tillage practices
...Show More Authors

View Publication
Scopus (11)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
The Study of properties structure and some optical properties forcopper Oxid (CuO) Thin film prepared by thermal evaporation in Vacume
...Show More Authors

in this paper copper oxide (cuO thin films were prepared by the method of vacum thermal evaporation a pressure.

View Publication Preview PDF
Publication Date
Thu Jul 16 2020
Journal Name
Polymer Bulletin
Fabrication and evaluation of structural, thermal, mechanical and optical behavior of epoxy–TEOS/MWCNTs composites for solar cell covering
...Show More Authors

View Publication
Crossref (35)
Crossref
Publication Date
Wed May 01 2019
Journal Name
Journal Of Engineering
Theoretical Analysis of Seepage through Homogeneous and Non-homogeneous Saturated-Unsaturated Soil
...Show More Authors

In this research, the program SEEP / W was used to compute the value of seepage through the homogenous and non-homogeneous earth dam with known dimensions. The results show that the relationship between the seepage and water height in upstream of the dam to its length for saturated soil was nonlinear when the dam is homogenous. For the non-homogeneous dam, the relationship was linear and the amount of seepage increase with the height of water in upstream to its length. Also the quantity of seepage was calculated using the method of (Fredlund and Xing, 1994) and (Van Genuchten, 1980) when the soil is saturated – unsaturated, the results referred to that the higher value of seepage when the soil is saturated and the lowe

... Show More
View Publication Preview PDF
Crossref (10)
Crossref
Publication Date
Sun Jan 01 2023
Journal Name
3rd International Conference On Smart Cities And Sustainable Planning
Theoretical structure of apparent and latent in the urban townscape: Subject review
...Show More Authors

View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Thu Oct 31 2013
Journal Name
Al-khwarizmi Engineering Journal
Theoretical and Practical Investigation of Blood Flow through Stenosed Coronary Lad Artery
...Show More Authors

Atherosclerosis is the most common causes of vascular diseases and it is associated with a restriction in the lumen of blood vessels. So; the study of blood flow in arteries is very important to understand the relation between hemodynamic characteristics of blood flow and the occurrence of atherosclerosis.

looking for the physical factors and correlations that explain the phenomena of existence the atherosclerosis disease in the proximal site of LAD artery in some people rather than others is achieved in this study by analysis data from coronary angiography as well as estimating the blood velocity from coronary angiography scans without having a required data on velocity by using some mathematical equations and physical laws. Fif

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 20 2022
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Theoretical Calculation of Photon Emission from Quark-Antiquark Annihilation Using QCD Theory
...Show More Authors

In this work, we calculate and analyze the photon emission from quark and anti-quark interaction during annihilation process using simple model depending on phenomenology of quantum chromodynamic theory (QCD). The parameters, which include the running strength coupling, temperature of the system and the critical temperature, carry information regarding photon emission and have a significant impact on the photons yield. The emission of photon from strange interaction with anti-strange is large sensitive to decreases or increases there running strength coupling. The photons emission increases with decreases running strength coupling and vice versa. We introduce the influence of critical temperature on the  photon emission  rate in o

... Show More
Crossref (4)
Crossref
Publication Date
Sun Apr 30 2017
Journal Name
Journal Of Engineering
The Effect of Fin Design on Thermal Performance of Heat Sink
...Show More Authors

      An experimental and computational study is conducted to analyze the thermal performance of heat sinks and to pick up more profound information in this imperative field in the electronic cooling. One important approach to improve the heat transfer on the air-side of the heat exchanger is to adjust the fin geometry. Experiments are conducted to explore the impact of the changing of diverse operational and geometrical parameters on the heat sink thermal
performance. The working fluid used is air. Operational parameters includes: air Reynolds number (from 23597 to 3848.9) and heat flux (from 3954 to 38357 W/m
2 ). Conformational parameters includes: change the direction of air flow and the area of conduct

... Show More
View Publication Preview PDF