A simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml respectively. The method was validated for its linearity, precision and accuracy .The proposed method was successfully applied for the determination of guaifenesin in syrups and industrial effluent samples.
Graphite nanoparticles were successfully synthesized using mixture of H2O2/NH4OH with three steps of oxidation. The process of oxidations were analysis by XRD and optics microscopic images which shows clear change in particle size of graphite after every steps of oxidation. The method depend on treatments the graphite with H2O2 in two steps than complete the last steps by reacting with H2O2/NH4OH with equal quantities. The process did not reduces the several sheets for graphite but dispersion the aggregates of multi-sheets carbon when removed the Van Der Waals forces through the oxidation process.
The aim of this research does not deal with evaluation occurs at any points in the design of the plan alternatives themselves or formulation of goals and objectives. The aim of this research is that test and evaluate the fully alternatives. We can therefore state as the principle that evaluation of alternative plans must be based on attempts to show how far each plan satisfies all the objectives are expressed as specification of the performance of the urban and regional system. The planner can submit the result (as in the traditional way) for each alternative, with particular reference to the weighting of objectives. The summery result can be presented and the preferred plan indicated that with largest index of Goals-achievement.
... Show MoreFrom different hospitals in Baghdad city, 25 clinical isolates of Proteus spp. were collected from different clinical samples, all isolates were identified as Proteus mirabilis by using bacteriological and biochemical assays in addition to Vitek-2 identification system. 15 (60%) isolates were identifying as Proteus mirabilis. The susceptibility of P. mirabilis isolates towards cefotaxime and ceftazidime was (66.6 %), (20%) consecutively; while extended spectrum β-lactamases producing P. mirabilis percentage was (30.7 %). Because blaVEB-1 was documented as an important indicator for increasing risk of extended spectrum beta ßlactamases producing P. mirabilis isolates that began to spread from many geographic area to Far east which inc
... Show MoreThe nonlinear optical properties response of nematic liquid crystal (6CHBT) and the impact of doping with two kinds of nanoparticles; Fe3O4 magnetic nanoparticles and SbSI ferroelectric nanoparticles have been studied using the non-linear dynamic method through z-scan measurement technique. This was achieved utilizing CW He-Ne laser. The pure LC and magnetic LC nanoparticle composite samples had a maximum absorption while the ferroelectric LC nanoparticle composite had a minimum absorption of the incident light. The nonlinear refractive index was positive for the pure LC and the rod-like ferronematic LC composite samples, while it was negative for the ferroelectric LC composite. The studying of the nonlinear optical
... Show MoreTo determine the relationship between celiac disease and reproductive disorder, twenty two women with recurrent spontaneous abortion (18-35) years have been investigated from the period 2017/11/1 – 2018/2/1 and compared wih twenty two parentally healthy women. All studied groups were carried out to measure antitissue transglutaminase IgA and IgG antibodies by Enzyme linked immunosorbent assay (ELISA) technique, There were a highly significant differences (P < 0.01) in the concentration of anti TtG IgA and IgG Ab compared to control group, while there was non-significant differences (P > 0.05) in the concentration of anti TtG IgA according to the age group and there was a significant difference (P < 0.05) in the concentration of anti TtG I
... Show MoreIn this research, the semiparametric Bayesian method is compared with the classical method to estimate reliability function of three systems : k-out of-n system, series system, and parallel system. Each system consists of three components, the first one represents the composite parametric in which failure times distributed as exponential, whereas the second and the third components are nonparametric ones in which reliability estimations depend on Kernel method using two methods to estimate bandwidth parameter h method and Kaplan-Meier method. To indicate a better method for system reliability function estimation, it has be
... Show More