Preferred Language
Articles
/
bsj-2610
Solvent Extraction And Spectrophotomteric Determination Of Cu(Ii) With Dicyclohexyl - 18- Crown-6
...Show More Authors

Liquid-Liquid Extraction of Cu(II) ion in aqueous solution by dicyclohexyl-18-crown-6 as extractant in dichloroethane was studied .The extraction efficiency was investigated by a spectrophometric method. The reagent form a coloured complex which has been a quantitatively extracted at pH 6.3. The method obeys Beer`s law over range from (2.5-22.5) ppm with the correlation coefficient of 0.9989. The molar absorptivity the stoichiometry of extracted complex is found to be 1:2. the proposed method is very sensitive and selective.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Dec 07 2018
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Effects of Aldosterone, Osteoprotegerin and Fibroblast Growth Factor-23 and Some Biochemical Markers in Chronic Kidney Disease Patients (Stage II-IV) among Patients with or without Cardiovascular Events
...Show More Authors

Chronic Kidney Disease (CKD) is a public health problem and many studies support the link between kidney dysfunction and cardiovascular events.  Aldosterone has been shown for decades that a plasma aldosterone concentration is elevated in CKD. Whilst, Osteoprotegerin (OPG), after its capacity to protect bone, also osteoprotegerin is elevated in patients with chronic kidney disease (CKD), where it could predict the deterioration of kidney function, cardiovascular, vascular events and all-cause mortality. On the other hand, fibroblast growth factors (FGFs), in patients with CKD, its levels seem to increase progressively as kidney function worsens. The aim of the present study is to assess the correlations between serum osteoprotegerin

... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Sat Oct 28 2023
Journal Name
Baghdad Science Journal
Indirect Flow Injection Spectrophotometric and Chromatographic Methods for the Determination of Mebendazole in Pharmaceutical Formulations
...Show More Authors

Chromatographic and spectrophotometric methods for the estimation of mebendazole in
pharmaceutical products were developed. The flow injection method was based on the oxidation of
mebendazole by a known excess of sodium hypochlorite at pH=9.5. The excess sodium hypochlorite is then
reacted with chloranilic acid (CAA) to bleach out its color. The absorbance of the excess CAA was recorded
at 530 nm. The method is fast, simple, selective, and sensitive. The chromatographic method was carried out
on a Varian C18 column. The mobile phase was a mixture of acetonitrile (ACN), methanol (MeOH), water
and triethylamine (TEA), (56% ACN, 20% MeOH, 23.5% H2O, 0.5% TEA, v/v), adjusted to pH = 3.0 with
1.0 M hy

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Journal Of Ovonic Research
Effect of copper on physical properties of CdO thin films and n-CdO: Cu / p-Si heterojunction
...Show More Authors

Publication Date
Tue Jan 01 2019
Journal Name
Progress In Industrial Ecology, An International Journal
Effect of V, In and Cu doping on properties of p-type ZnSe/Si heterojunction solar cell
...Show More Authors

View Publication
Scopus (16)
Crossref (19)
Scopus Crossref
Publication Date
Sun Jan 06 2019
Journal Name
Progress In Industrial Ecology – An International Journal,
Effect of V, In and Cu doping on properties of p-type ZnSe/Si heterojunction solar cell
...Show More Authors

The enhancement of ZnSe/Si Heterojunction by adding some elements (V, In and Cu) as impurities is the main goal because they contribute to the manufacturing of renewable energy equipment, such as solar cells. This paper describes the preparation of thin films ZnSe with V, In and Cu doped using thermal evaporation method with a vacuum of 10–5 Torr. The thin film was obtained from this work could be applied in heterojunction solar cell because of several advantages including high absorption coefficient value and direct band gap. The samples prepared on a glass and n-type Si wafer substrate. These films have been annealed for 1 h in 450 K. X-ray diffraction XRD results indicated that ZnSe thin film possesses poly-crystalline structure after

... Show More
View Publication
Publication Date
Tue Feb 01 2022
Journal Name
Journal Of Ovonic Research
Effect of copper on physical properties of CdO thin films and n-CdO: Cu / p-Si heterojunction
...Show More Authors

Scopus (16)
Scopus
Publication Date
Thu Jun 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Emulsion Liquid Membrane for Pesticides Removal from Aqueous Solution: Emulsion Stability, Extraction Efficiency and Mass Transfer Studies
...Show More Authors

The current study investigated the stability and the extraction efficiency of emulsion liquid membrane (ELM) for Abamectin pesticide removal from aqueous solution. The stability was investigated in terms of droplet emulsion size distribution and emulsion breakage percent. The proposed ELM included a mixture of corn oil and kerosene (1:1) as a diluent, Span 80 (sorbitan monooleate) as a surfactant and hydrochloric acid (HCl) as a stripping agent without utilizing a carrier agent. Parameters such as homogenizer speed, surfactant concentration, emulsification time and internal to organic volume ratio (I/O) were evaluated. Results show that the lower droplet size of 0.9 µm and higher stable emulsion in terms of breakage percent of 1.12 % we

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Mon Mar 11 2019
Journal Name
Baghdad Science Journal
Determination of Nicotine Extracted from Eggplant and Green Pepper by HPLC
...Show More Authors

Nicotine was separated from eggplant and green pepper seeds (Solanaceous) by High Performance Liquid Chromatography (HPLC).The concentration of nicotine in the eggplant extract (0.871-0.877 μg/ml) was determined by injecting standard material with 0.5 and 1.5 μg/ml, while the concentrations of nicotine in green pepper extract (0.613-0.618 μg/ml) was determined when the standard material was injected with 0.5 and 1.5 μg/ml. The qualitative chemical data was calculated from derivations of the standard material. Nicotine concentration was measured qualitatively in both extracts through the calibration curve and method of the standard addition. This technique has high accuracy and compatibility, bringing the proportion of relati

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (1)
Scopus Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Current Research In Microbiology And Biotechnology
Determination of the relationship between Celiac disease and recurrent spontaneous abortion
...Show More Authors

To determine the relationship between celiac disease and reproductive disorder, twenty two women with recurrent spontaneous abortion (18-35) years have been investigated from the period 2017/11/1 – 2018/2/1 and compared wih twenty two parentally healthy women. All studied groups were carried out to measure antitissue transglutaminase IgA and IgG antibodies by Enzyme linked immunosorbent assay (ELISA) technique, There were a highly significant differences (P < 0.01) in the concentration of anti TtG IgA and IgG Ab compared to control group, while there was non-significant differences (P > 0.05) in the concentration of anti TtG IgA according to the age group and there was a significant difference (P < 0.05) in the concentration of anti TtG I

... Show More
Publication Date
Tue Mar 30 2021
Journal Name
Baghdad Science Journal
Spectrophotometric and Spectrofluorimetric Determination of Terazosin in Tablets by Eosin Y
...Show More Authors

Simple, sensitive and accurate two methods were described for the determination of terazosin. The spectrophotometric method (A) is based on measuring the spectral absorption of the ion-pair complex formed between terazosin with eosin Y in the acetate buffer medium pH 3 at 545 nm. Method (B) is based on the quantitative quenching effect of terazosin on the native fluorescence of Eosin Y at the pH 3. The quenching of the fluorescence of Eosin Y was measured at 556 nm after excitation at 345 nm. The two methods obeyed Beer’s law over the concentration ranges of 0.1-8 and 0.05-7 µg/mL for method A and B respectively. Both methods succeeded in the determination of terazosin in its tablets

View Publication Preview PDF
Scopus Crossref