A simple ,accurate and sensitive spectrophotometric method has been developed the determination of Cobalt(II) and Cupper (II) .The method is based on the chelation of Co(II) and Cu(II) ions with 4-(4´-pyrazolon azo) -2-Naphthol(APAN) in aqueous medium . The complexes have a maximum absorption at (513) and (506) nm and ? max 0.531×10 4 and 0.12×10 5 L.mol -1.cm -1 for Co(II) and Cu(II) respectively .The reagent and two complexes have been prepared in ethanolic solution.The stoichiometry of both complexes were found to be 1:2 (metal :legend) .The effects of various cations and anions on Co(II) and Cu(II) determination have been investigated .The stability constants and standard deviations for Co(II) and Cu(II) 0.291 x107 ,0.909X108 L.mol -1 ,(0.291) and (0.332) respectively .The optimum condition for full color development for described methods were applied satisfactorily to synthetic samples.
In this research study the synodic month for the moon and their
relationship with the mean anomaly for the moon orbit and date A.D
and for long periods of time (100 years), we was design a computer
program that calculates the period of synodic months, and the
coordinates of the moon at the moment of the new moon with high
accuracy. During the 100 year, there are 1236 period of synodic
months.
We found that the when New Moon occurs near perigee (mean
anomaly = 0°), the length of the synodic month at a minimum.
Similarly, when New Moon occurs near apogee (mean anomaly =
180°), the length of the synodic month reaches a maximum. The
shortest synodic month on 2053 /1/ 16 and lasted (29.27436) days.
The lo
Roughness length is one of the key variables in micrometeorological studies and environmental studies in regards to describing development of cities and urban environments. By utilizing the three dimensions ultrasonic anemometer installed at Mustansiriyah university, we determined the rate of the height of the rough elements (trees, buildings and bridges) to the surrounding area of the university for a radius of 1 km. After this, we calculated the zero-plane displacement length of eight sections and calculated the length of surface roughness. The results proved that the ranges of the variables above are ZH (9.2-13.8) m, Zd (4.3-8.1) m and Zo (0.24-0.48) m.
In this research study the synodic month for the moon and theirrelationship with the mean anomaly for the moon orbit and date A.Dand for long periods of time (100 years), we was design a computerprogram that calculates the period of synodic months, and thecoordinates of the moon at the moment of the new moon with highaccuracy. During the 100 year, there are 1236 period of synodicmonths.We found that the when New Moon occurs near perigee (meananomaly = 0°), the length of the synodic month at a minimum.Similarly, when New Moon occurs near apogee (mean anomaly =180°), the length of the synodic month reaches a maximum. Theshortest synodic month on 2053 /1/ 16 and lasted (29.27436) days.The longest synodic month began on 2008 /11/ 27 a
... Show MoreThe liver (hepatic) is one of the largest glands or organs of the digestive system in the body of living organisms, including rodents, take the squirrel in this study for example. The study and the collection of sources emerged to be put into the hands of those, especially those interested in histological studies, including junior or professionals and veterinarians, knowledge of the stains used in the research and their final results.
Abstract: Objectives: The lowest dose of bromocriptine, necessary for suppression of lactation in rats, was estimated in this investigation. Methodology: Fifty healthy lactating rats were treated with different doses of bromocriptine. Cessation of lactation was assessed clinically and histologically. Results: Revealed that the lowest dose capable of lactation suppression is 4 mg bromocriptine / kg body wt. / day. It is very important to know the exact dose, which can suppress lactation in rats because these laboratory animals are commonly employed in experiments concerning this topic. Key words: Bromoci
In this study, the sonochemical degradation of phenol in water was investigated using two types of ultrasonic wave generators; 20 kHz ultrasonic processor and 40 kHz ultrasonic cleaner bath. Mineralization rates were determined as a function of phenol concentration, contact time, pH, power density, and type of ultrasonic generator. Results revealed that sonochemical degradation of the phenol conversion was enhanced at increased applied power densities and acidic conditions. At 10 mg/L initial concentration of phenol, pH 7, and applied power density of 3000 W/L, the maximum removal efficiency of phenol was 93% using ultrasonic processor at 2h contact time. Whereby, it was 87% using and ultrasonic cleaner bath at 16h contact time and 150 W
... Show MoreABSTRACT Background: Diabetes and periodontitis are complicated prolonged disorders through a recognized two-way association. There is elongated-conventional mark that hyperglycaemia in diabetes is affected on immune-inflammatory response and disturb the action of osteoclast and in balance bone turnover, which might rise the person vulnerability to the progress of prolonged periodontitis. Osteocalcin is one of the greatest plentiful matrix proteins originate in bones and produced absolutely there. Small osteocalcin crumbles are noticed in regions of bone remodeling and are in fact degradation products of the bone matrix, that is released outside cells into the Gingival Crevicular Fluid (GCF) and saliva after destruction of periodontal tissu
... Show MoreMany designs have been suggested for unipolar magnetic lenses based on changing the width of the inner bore and fixing the other geometrical parameters of the lens to improve the performance of unipolar magnetic lenses. The investigation of a study of each design included the calculation of its axial magnetic field the magnetization of the lens in addition to the magnetic flux density using the Finite Element Method (FEM) the Magnetic Electron Lenses Operation (MELOP) program version 1 at three different values of current density (6,4,2 A/mm2). As a result, the clearest values and behaviors were obtained at current density (2 A/mm2). it was found that the best magnetizing properties, the high
... Show More