Preferred Language
Articles
/
bsj-2605
In Vitro Study of MefenamateStarch as Drug Delivery System
...Show More Authors

Mefenamic acid was esterified with starchwith[1:1] Molar ratio, as drug substituted with natural polymer, to prolongthe period of hydrolysis of drug polymer with other advantages. The new prodrug starch was characterized by FT-IR and UV-Visible and 1H-NMR spectroscopies. The physical properties were studied and controlled drug release was studied in different pH values at 37oC. The stability of drug was carried out by measuring the absorbance of mefenamic starch which hydrolyzed in HCl solution of pH 1.1 (artificial gastric fluid) and phosphate buffer of pH 7.4 (simulating intestinal fluid SIF) at 37oC for several days. The thermal analysis such as DSC was studied.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Formulation and in vitro Evaluation of In-situ Gelling Liquid Suppositories for Naproxen
...Show More Authors

In-situ gelation is a process of gel formation at the site of application, in which a drug product formulation that exists as a liquid has been transformed into a gel upon contact with body fluids. As a drug delivery agent, the in-situ gel has an advantage of providing sustained release of the drug agent.  In-situ gelling liquid suppositories using poloxamer 188 (26-30% W/W) as a suppository base with 10% W/W naproxen were prepared, the gelation temperature of these preparations were measured and they were all above the physiological temperature. Additives such as polyvinylpyrrolidin "PVP" ,hydroxylpropylmethylcellulose  "HPMC", sodium alginate and sodium chloride were used in concentration ranging from (0.25-1

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Mar 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Different Pouring Interval of Conventional Impression on the Marginal Accuracy of Full Contour Zirconia Crowns in Comparison with Digital Impression (An in vitro study)
...Show More Authors

Background: The success and maintenance of indirect dental restorations is closely related to the marginal accuracy, which is affected by many factors like preparation design, using of different fabrication techniques, and the time of taking final impression and pouring it. The purpose of this in vitro study was to evaluate the effect of different pouring time of conventional impression on the vertical marginal gap of full contour zirconia crowns in comparison with digital impression technique. Materials and Methods: Forty sound recently extracted human permanent maxillary first premolar teeth of comparable size and shape were collected. Standardized preparation of all teeth samples were carried out to receive full contour zirconia crown re

... Show More
View Publication
Crossref
Publication Date
Fri Dec 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Different Pouring Interval of Conventional Impression on the Marginal Accuracy of Full Contour Zirconia Crowns in Comparison with Digital Impression (An in vitro study)
...Show More Authors

Background: The success and maintenance of indirect dental restorations is closely related to the marginal accuracy, which is affected by many factors like preparation design, using of different fabrication techniques, and the time of taking final impression and pouring it. The purpose of this in vitro study was to evaluate the effect of different pouring time of conventional impression on the vertical marginal gap of full contour zirconia crowns in comparison with digital impression technique. Materials and Methods: Forty sound recently extracted human permanent maxillary first premolar teeth of comparable size and shape were collected. Standardized preparation of all teeth samples were carried out to receive full contour zirconia crown re

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Nov 13 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of thermocycling on microleakage analysis of bulk filled base composite in comparison to incrementally placed nanohybrid composite in class II MOD restorations (An in vitro study)
...Show More Authors

Background: The study aim was to evaluate thermocycling effect on microleakage of occlusal and cervical margins of MOD cavity filled with bulk filled composites in comparison to incrementally placed nanohybrid composite and to evaluate the difference in microleakage between enamel and dentin margins for the three materials groups. Materials and method: Forty eight maxillary first premolars were prepared with MOD cavities. Samples were divided into three groups of sixteen teeth according to material used: Grandio: Grandio. SDR: SDR +Grandio. X-tra: X-tra base + Grandio. Each group was subdivided into two according to be thermocycled or not. After 24 hrs immersion in 2% methylene blue, samples weresectioned and microleakage was estimated. Res

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 01 2015
Journal Name
Baghdad Science Journal
Synthesis of Mixed Ligand Complexes of M(II) Dithiocarbamato Derivative and 2,2'-bipyridyl and Study their Cytotoxic Effect Against HepG2 Cell Line in vitro
...Show More Authors

Mixed ligand of Co and Ni (II) complexes were prepared from [5-(p-nitrophenyl)-4/-phenyl-1,2,4-triazole-3-dithiocarbamato hydrazide](TRZ.DTC) as primary ligand and 2,2'-bipyridyl (bipy) as a co-ligand with metal salts. These complexes were analytically and spectroscopically characterized in solid state by elemental analyses, flame atomic absorption, magnetic susceptibility and molar conductance measurements, as well as by UV–Vis and FTIR spectroscopy. Infrared, ultra violet spectra reveal a bidentate coordination of the two ligands with metal ions 1:1:1 mole ratio. Room temperature magnetic moments and solid reflectance spectra data indicate paramagnetic complexes with five-coordinate square pyramidal geometry for nickel (II) comple

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed May 01 2013
Journal Name
Chemical And Process Engineering Research
Synthesis and Characterization of Polycyclicacetal Derived from PEG & Erythro-Ascorbic Acid Derivative and Study Its Effect on the Activity of ACh Enzyme (In Vitro)
...Show More Authors

Polycyclicacetal was prepared from the reaction of PEG with aldehyde derived from Erythro-ascorbic acid (pentulosono-ɣ-lactone-2,3-enedianisoate).All these compounds were characterized by Thin Layer Chromatography (TLC) and FTIR spectra and aldehyde was also characterized by (U.V-Vis), 1HNMR, 13CNMR, and mass spectra.The inhibitory effect of prepared polymer on the activity of human serum AcetylCholinesterase has been studied in vitro. The polymer showed a remarkable activity at low concentration (4.7x10-3 – 4.7x10-8M).

Preview PDF
Publication Date
Thu Nov 13 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Aging effect of different types of composite resin restoration on shear bond strength to different orthodontic adhesives with sapphire bracket (In vitro comparative study)
...Show More Authors

Background: This study was performed to determine the effect of aging of different types of composite material restorations on: Shear bond strength (SBS) to light cure and no mix chemical cure orthodontic adhesives with sapphire bracket and the debonding failure sites. Materials and methods: One hundred forty four composite disks were made from three different composite resin materials which are: 3M Filtek Z250, 3M filtek Z350 and 3M Valux plus, each group with (48) disks each, then according to the duration of storage each group was subdivided into two equal groups one of them stored for one day and the other was stored for one month, then each group was further subdivided into two equal subgroups with (12) disks each one bonded with ligh

... Show More
View Publication Preview PDF
Publication Date
Fri Sep 15 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Enamel Protective Agent on Shear and Tensile Bond Strength of Stainless Steel Brackets by Using Different Adhesive Agents (In Vitro Study)
...Show More Authors

Background: Decalcification of surface enamel adjacent to fixed orthodontic appliances, in the form of white spot lesions, is a wide spread and familiar well-known side effect of orthodontic treatment. The present study was carried out to evaluate the effect of enamel protective agent (Clinpro white varnish) on shear and tensile bond strength of Dentaurum orthodontic stainless steel brackets by using 3M Unitek and Ormco as orthodontic adhesive agents. Materials and methods: Sixty-four extracted human upper first premolar teeth were selected and randomly divided into two groups with 32 teeth each, representing the shear and tensile bond strength testing groups. Then according to the type of bonding adhesive and the addition of Clinpro before

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 30 2022
Journal Name
International Journal Of Drug Delivery Technology
Physiological and Immunological Assessment in Infertile Women Undergoing In-vitro Fertilization
...Show More Authors

All the available reports on the issue of infertility confirmed the increase in this population problem worldwide. Although the accurate estimate of the number of infertile people is due to several reasons, including the discrepancy in the true definition of infertility (whether it extends for one, two or five years of failed pregnancy attempts), as well as the great discrepancy in the size of the selected population groups (large population sample size versus epidemiological studies) and defining the category that diagnosed included (individuals, women, or couples). The goal of today’s IVF program is to obtain high-quality embryos with high efficiency in development, which leads to an increase in live birth rates.

View Publication Preview PDF
Scopus Crossref
Publication Date
Tue Sep 01 2015
Journal Name
Journal Of Biomechanics
In vitro wear testing of a contemporary design of reverse shoulder prosthesis
...Show More Authors

Reverse shoulder arthroplasty is an increasingly common surgical intervention. However there are concerns and known limitations in relation to such joint replacement, while novel designs of reverse shoulder prostheses continue to appear on the market. Many claim to offer improvements over older designs but such assertions are difficult to validate when there is no consensus as to how such implants should be tested in vitro or even if such testing is necessary. In order to permit appropriate in vitro testing of reverse shoulder prostheses a unique, multi-station test rig was designed which was capable of applying motion in three axes to test prostheses. The shoulder simulator can apply up to 110° of motion in the flexion–extension and abd

... Show More
View Publication
Scopus (29)
Crossref (28)
Scopus Clarivate Crossref