A number of pulsed experiments have been carried out using a high-voltage circuit containing R,L, and C in certain arrangements. A spherical spark gap of steel electrodes was used as a high-current switch operated by a voltage of up to 8kV and triggered in both self-triggering and third-electrode triggering modes. Current measurements were carried out by using both current-viewing resistor and Rogowski coils designed for this purpose. Typical current waveforms have shown obvious dominating inductance effect of the circuit components in an underdamped oscillation. The behavior of the circuit impedance was studied by recording both pulsed current peaks and the charging voltages when currents of up to 2.5kA were recorded. The duration of these current pulses were found to extend between 0.1?s and 0.3?s depending on the values of the circuit components as well as the spacing of the spark gap electrodes along which the plasma propagates at atmospheric pressure. Over the whole range of experimental conditions, the average nominal impedance values were ranged between (2-10)? depending on the gap and circuit parameters. Typical damage patterns were observed with average diameters of up to 8.3 mm on the high voltage electrode and 10.5 mm on the grounded sphere resulting from accumulative discharges and power dissipation within the gap.
In this work a study and calculation of the normal approach between two bodies, spherical and rough flat surface, had been conducted by the aid of image processing technique. Four kinds of metals of different work hardening index had been used as a surface specimens and by capturing images of resolution of 0.006565 mm/pixel a good estimate of the normal approach may be obtained the compression tests had been done in strength of material laboratory in mechanical engineering department, a Monsanto tensometer had been used to conduct the indentation tests.
A light section measuring equipment microscope BK 70x50 was used to calculate the surface parameters of the texture profile like standard deviation of asperity peak heights, centre lin
A statistical optical potential has been used to analyze and
evaluate the neutron interaction with heavy nuclei 197Au at the
neutron energy range (1-20 MeV). Empirical formulae of the optical
potentials parameters are predicted by using ABAREX Code with
minimize accuracy compared with experimental bench work data.
The total elastic, absorption, shape elastic and total compound crosssections are calculated for different target nuclei and different
incident neutron energies to predict the appropriate optical
parameters that suit the present interaction. Also the dispersion
relation linking between real and imaginary potential is analyzed
with more accuracy. The results indicate the behavior of the
dispersion c
In this work a study and calculation of the normal approach between two bodies,
spherical and rough flat surface, had been conducted by the aid of image processing
technique. Four kinds of metals of different work hardening index had been used as a
surface specimens and by capturing images of resolution of 0.006565 mm/pixel a good estimate of the normal approach may be obtained the compression tests had been done in strength of material laboratory in mechanical engineering department, a Monsanto tensometer had been used to conduct the indentation tests. A light section measuring equipment microscope BK 70x50 was used to calculate the surface parameters of the texture profile like standard deviation of asperity peak heights
The significant shortage of usable water resources necessitated the creation of safe and non-polluting ways to sterilize water and rehabilitate it for use. The aim of the present study was to examine the ability of using a gliding arc discharge to inactivate bacteria in water. Three types of Bacteria satisfactory were used to pollute water which are Escherichia coli (Gram-negative), Staphylococcus aurous (Gram-positive) and salmonella (Gram-negative). A DC power supply 12V at 100 Hz frequency was employed to produce plasma. pH of water is measured gradually during the plasma treatment process. Contaminated water treated by gliding arc discharge at steadying the gas flow rate (1.5 l/mi
Background: Intense pulsed light (IPL) devices produce polychromatic incoherent high-intensity pulsed light with a specified wavelength spectrum, fluence, and pulse duration through the use of flashlamps and bandpass filters. Similar to lasers, IPL devices operate on the selective photothermolysis principle, with melanin acting as the chromophore. Despite this similarity, they are constructed differently and produce different amounts of light
Aim of the study: To investigate the efficacy of IPL home-use device in hair reduction technique for women with unwanted facial hair.
Subjects and methods: The study was conducted in Baghdad on forty-five female subjects with Fitzpatri
... Show MoreEbastine (EBS) is a poorly water-soluble antihistaminic drug; it belongs to the class II group according to the biopharmaceutical classification system (BCS). The aim of the present work was to enhance the solubility, dissolution rate and micromeritic properties of the drug, by formulating it as spherical crystal agglomerates by Quasi Emulsion Solvent Diffusion (QESD) method.
Spherical crystal agglomerates (SCAs) were prepared in presence of three solvents dichloromethane (DCM), water and chloroform as a good solvent, poor solvent and bridging solvent respectively. Agglomeration of EBS involved the use of some hydrophilic polymers like polyethylene glycol 4000 (PEG 4000), polyvinyl pyrrolidine K30 (PVP K30), D-?-tocopheryl
... Show MorePolycyclic aromatic hydrocarbons (PAHs) were measured in aerosol from air samples, which collected for the period from April 2012 to February 2013, in Baghdad city, at Daura Refinery. Aerosol samples were collected on cellulose fiber filters for 1.5 h in each site for the morning and evening time. These aerosol samples undergone soxhlet extraction.
After the extraction, 49 samples were analyzed by GC-MS in order to determin 16 PAH compounds. The parameters temperature, relative humidity and wind speed were measured during the measurement period. The PAH concentrations were different for location inside and outside Daura refinery. Naphthalene was the most abundant PAH detected in all points at the site sampling for all seasons. There i
In this paper, the fundamental harmonic of a Nd:YAG laser (Q-switched 1064nm wavelength, 1 Hz repetition rate and 9 ns pulse duration) has been used for the ablation of cadmium samples in air at atmospheric pressure and the generation of the cadmium plasma. The experimentally observed lines of cadmium plasma emission have been used to calculate the plasma parameters such as (electron temperature (TReR), electron density (nReR), Debye length (λRDR) and plasma frequency (ωRpR)). Line pair ratio of neutral species have been used for the electron temperature and electron density measurements. Plasma parameters were studied as a functions of laser pulse energy.
This work revealed the spherical aromaticity of some inorganic E4 cages and their protonated E4H+ ions (E=N, P, As, Sb, and Bi). For this purpose, we employed several evaluations like (0D-1D) nucleus independent chemical shift (NICS), multidimensional (2D-3D) off-nucleus isotropic shielding σiso(r), and natural bond orbital (NBO) analysis. The magnetic calculations involved gauge-including atomic orbitals (GIAO) with two density functionals B3LYP and WB97XD, and basis sets of Jorge-ATZP, 6-311+G(d,p), and Lanl2DZp. The Jorge-ATZP basis set showed the best consistency. Our findings disclosed non-classical aromatic characters in the above molecules, which decreased from N to Bi cages. Also, the results showed more aromaticity in E4 than E4H+
... Show MoreAbstract: A home-made dc sputtering is characterized by cathode potential of 250-2500 V and sputtering gas pressures of (3.5×10-2 – 1.5) mbar. This paper studies in experiment the breakdown of argon, nitrogen, and oxygen in a uniform dc electric field at different discharge gaps and cathode potentials. Paschen curves for Argon, Nitrogen, and oxygen are obtained by measuring the breakdown voltage of gas within a stainless steel vacuum chamber with two planar, stainless steel electrodes. The Paschen curves in Ar, N2, and O2 gases show that the breakdown voltage between two electrodes is a function of pd (The product of the pressure inside the chamber and distance between the electrodes). Current-voltage characteristics visualization of the
... Show More