Preferred Language
Articles
/
bsj-2533
Measurement of Photon Buildup Factor for Samples of Iraqi Carbon Black Material
...Show More Authors

The buildup factor was measured after irradiating Iraq carbon black powder using each of and sources respectively, using mixing ratios 40% & 50% for thickness range . The results showed that the buildup factor depends on energy and has limited dependence on the mixing ratio. The QIFT program succeeded accenting for the experimental results even for expected values more than 4 m.f.p outside the thickness range.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Sep 07 2014
Journal Name
Baghdad Science Journal
Detection of RAF fusion transcripts in FFPE samples of Medullablastoma and Ependymom in Iraqi children with RT-RQPCR assays
...Show More Authors

Medulloblastomas and ependymomas are the most common malignant brain tumors in children. However genetic abnormalities associated with their development and prognosis remain unclear. Recently two gene fusions, KIAA1549–BRAF and SRGAP3–RAF1 have been detected in a number of brain tumours. We report here our development and validation of RT-RQPCR assays to detect various isoforms of these two fusion genes in formalin fixed paraffin embedded (FFPE) tissues of medulloblastoma and ependymoma. We examined these fusion genes in 44 paediatric brain tumours, 33 medulloblastomas and 11 ependymomas. We detected both fusion transcripts in 8/33, 5/33 SRGAP3 ex10/RAF1 ex10, and 3/33 KIAA1549 ex16/BRAF ex9, meduloblastomas but none in the 11 ep

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Feb 20 2019
Journal Name
Iraqi Journal Of Physics
Measurement of radon concentrations for some houses in Al-Najaf city /Iraq
...Show More Authors

    Measurement of radon concentration level was carried out in 40 houses in Al – Najaf city during summer season of 2012. Long term measurement of indoor of old building radon concentrations have been taken, using a previously calibrated passive diffusion dosimeters containing CR – 39 solid state nuclear track detectors which are very sensitive for alpha particles. The measurement of the indoor radon concentration obtained in summer in these regions ranged from 11.654±4.216 Bq.m-3 to 53.610±8.777 Bq.m-3. The results were within universally permitted levels.     

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Feb 12 2024
Journal Name
Journal Mustansiriyah Of Sports Science
Standardization test for the measurement of offensive basketball composite skills(16) years
...Show More Authors

Summary of the researchThe style of playing in basketball, represented by the performance of complex movements as a result of the rapid movement and changing positions is one of the advantages of this game, which adds beauty and excitement to this game, so it was necessary for players to use forms of mobility and complex skills mixed with precision and speed, In the attack to overcome the difficult positions defenders are trying to impose on the attacking team.Complex offensive skills in basketball are difficult skills that a player can not easily perform so they need to be specially trained to handle those situations so that the player can use them in difficult situations.The research community represented a sample of Baghdad players for t

... Show More
Publication Date
Sun Jun 12 2011
Journal Name
Baghdad Science Journal
Measurement of Background Radioactivity in Sewage Sludge for Baghdad City Treatment Stations
...Show More Authors

Sewage sludge samples were collected from Al-rasafa and Al-karkh refinement stations which represent the main stations of Baghdad city. Samples were collected from all treatment stages: before, after, and during refinement processes. The High Purity Germanium Coaxial Detector system with energy resolution 1.8 keV for energy line 1333 keV of Co – 60 radioactive sources was used to measure radioactivity from both natural and artificial sources. GENIE – 2000 analysis the results statistically and qualitatively. The results showed that all sewage sludge samples exhibited natural radioactive level and sometimes less than the international regular standards, but Al–Karkh station showed increment in radioactive levels than Al– Rasa

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Nov 01 2016
Journal Name
2016 International Conference On Advances In Electrical, Electronic And Systems Engineering (icaees)
Efficient routing algorithm for VANETs based on distance factor
...Show More Authors

There has been a great deal of research into the considerable challenge of managing of traffic at road junctions; its application to vehicular ad hoc network (VANET) has proved to be of great interest in the developed world. Dynamic topology is one of the vital challenges facing VANET; as a result, routing of packets to their destination successfully and efficiently is a non-simplistic undertaking. This paper presents a MDORA, an efficient and uncomplicated algorithm enabling intelligent wireless vehicular communications. MDORA is a robust routing algorithm that facilitates reliable routing through communication between vehicles. As a position-based routing technique, the MDORA algorithm, vehicles' precise locations are used to establish th

... Show More
View Publication
Scopus (8)
Crossref (7)
Scopus Crossref
Publication Date
Sun Jun 30 2013
Journal Name
Al-kindy College Medical Journal
Diabetes Mellitus as a Risk Factor for Pulmonary Tuberculosis
...Show More Authors

Background: In the past, an association between Tuberculosis (TB) and Diabetes Mellitus (DM) was widely accepted, today the potential public health and clinical importance of this relationship seems to be largely ignored. The national clinical and policy guidance in the UK on the central of TB, for example, does not consider the relationship with DM.Objectives: To determine the risk of association between diabetes mellitus and pulmonary TB.Methods: A retrospective study conducted in Ibn Zuhr hospital for chest diseases from Jan 2008 – sep 2010 , included in the study 402 patients with TB divided into diabetic & non diabetic, 96 (23.8%) were diabetic while other 306 were TB not diabetic.Results: Risk of TB among DM patients were cle

... Show More
View Publication Preview PDF
Publication Date
Fri Aug 26 2022
Journal Name
Journal Of Contemporary Medical Sciences
Measurement of the serum level of Leucine-rich alpha-2-glycoprotein-1 in hospitalized Iraqi COVID-19 Patients
...Show More Authors

Objective: The study aimed to assess Leucine-rich alpha-2-glycoprotein-1 biomarker serum level in hospitalized COVID-19 patients. Methods: The case control study from multi-centers in Baghdad included 45 adult patients (19 females and 26 males) with COVID-19, diagnosed with a positive real-time reverse transcription polymerase chain reaction and excluded negative RT-PCR for COVID-19 and comorbidity conditions. Second group, was 43 control (20 females and 23 males). Results: This study found a decrease Leucine-rich alpha-2-glycoprotein-1 biomarker serum level in these patients and a significant difference in D. dimer, neutrophil count, lymphocyte count, and the neutrophil-lymphocyte ratio between the patients and controls at a P valu

... Show More
Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Tue Dec 01 2009
Journal Name
Journal Of Lightwave Technology
A Random Number Generator Based on Single-Photon Avalanche Photodiode Dark Counts
...Show More Authors

View Publication
Scopus (24)
Crossref (22)
Scopus Clarivate Crossref
Publication Date
Mon Aug 01 2011
Journal Name
International Journal Of Research And Reviews In Computer Science
Detection of the photon number splitting attack by using decoy states quantum key distribution system
...Show More Authors

The goal of this work is to check the presence of PNS (photon number splitting) attack in quantum cryptography system based on BB84 protocol, and to get a maximum secure key length as possible. This was achieved by randomly interleaving decoy states with mean photon numbers of 5.38, 1.588 and 0.48 between the signal states with mean photon numbers of 2.69, 0.794 and 0.24. The average length for a secure key obtained from our system discarding the cases with Eavesdropping was equal to 125 with 20 % decoy states and 82 with 50% decoy states for mean photon number of 0.794 for signal states and 1.588 for decoy states.

Publication Date
Sun Aug 01 2021
Journal Name
Laser Micro- And Nano-scale Processing
Physical principles of laser–material interaction regimes for laser machining processes
...Show More Authors

Lasers, with their unique characteristics in terms of excellent beam quality, especially directionality and coherency, make them the solution that is key for many processes that require high precision. Lasers have good susceptibility to integrate with automated systems, which provides high flexibility to reach difficult zones. In addition, as a processing tool, a laser can be considered as a contact-free tool of precise tip that became attractive for high precision machining at the micro and nanoscales for different materials. All of the above advantages may be not enough unless the laser technician/engineer has enough knowledge about the mechanism of interaction between the laser light with the processed material. Several sequential phenom

... Show More
View Publication
Crossref (1)
Crossref