Four samples were collected from the wastewater of State Battery Manufacturing Company (SBMC); Babylon 2 factory in AL-Waziriya district, as triplicates. Physical and chemical measurements were carried out such as temperature, pH, Lead concentrations and their ranges were: (19.5-34.5) °C, (6.1-6.4) and (4.5-6.5) mg/L, respectively. Six dominant Bacillus spp. isolates were isolated from these samples; namely, Bacillus subtilis N1, Bacillus subtilis N2, Bacillus subtilis N3, Bacillus cereus N4, Bacillus cereus N5 , Bacillus cereus N6. These isolates were capable of removing Lead from aqueous solutions in a capacity reached 27.6 ± 1.4, 10.1 ± 1.7, 74.5 ± 0.7, 8.93 ± 2.8, 8.1 ± 3.5, 1.6± 0.7 mg/L, respectively. Whereas cell walls, extracted from the same isolates, were able to remove Pb with high efficiency reached 77.7 ± 0.3, 18.6 ± 1.2, 9.5 ± 0.7, 42.4 ± 6.3, 9.9 ± 0.9, 6.7 ± 2.1 mg/L, respectively. This study showed that there is high variation (P<0.05) in the ability of the isolated bacteria for lead biosorption. However, Bacillus subtilis N3 were the most efficient (P<0.05) in uptaking the lead from its aqueous solutions in average of (74.5 ± 0.7) mg/L compared to other bacterial species. FTIR spectrum illustrated that hydroxyl groups, carboxyl, amide, and carbonyl are the major sites for Pb binding. Cell walls of B. subtilis were able to remove almost all Pb ions from the wastewater sample (4.5 mg/L) taken from the wastewater treatment unit in the State Battery Manufacturing Company.
Staphylococcus Sp.is the most common type of bacteria found in contamination place, we design this
study to compare the contamination accident between two hospitals in Baghdad.One of them isthe Burns
Specialist Hospital in the Medical CityinRusafa and another one is Al-Karama Hospital in Karkh. The
samples were collected fromOperativeWard No1 (OW1), Operative Ward No2 (OW2), Consulting Pharmacy
(CP), Emergency Room (ER), Reception Room (RR), Women's Ward (WW) and Men's Ward (MW).The
samples were taken from inside each clinical unit, surfaces, food, and air. The results showed that the
number of samples containing Staphylococcus sp. bacteria is 81, including 45 belonging to Al-Karama Burns
Ward Ho
Leuconostoc bacteria was isolated from local pickled cabbage (Brassica oleracea capitata) and identified as Leuconostoc mesenteroides by morphology,biochemical and physiological. The local isolated L. mesenteroides bacteria under the optimal conditions of dextran production showed that, the highly production of dextran was 7.7g achieved by using a modified natural media comprised of 100ml whey, 10g refined sugar, 0.5g heated yeast extract, 0.01g CaCl2, 0.001g MgSO4, 0.001g MnCl2 and 0.001g NaCl at pH 6 and 25̊C for 24 hr of fermentation and by using 1ᵡ106 cell/ml as initial inoculums volume. Some applications in food technology (Ice cream, Loaf, Ketchup and Beef preservation) have been performed with processed dextran. The result
In this study, the optimum conditions for COD removal from petroleum refinery wastewater by using a combined electrocoagulation- electro-oxidation system were attained by Taguchi method. An orthogonal array experimental design (L18) which is of four controllable parameters including NaCl concentration, C.D. (current density), PH, and time (time of electrolysis) was employed. Chemical oxygen demand (COD) removal percentage was considered as the quality characteristics to be enhanced. Also, the value of turbidity and TDS (total dissolved solid) were estimated. The optimum levels of the studied parameters were determined precisely by implementing S/N analysis and analysis of variance (ANOVA). The optimum conditions were found to be NaCl = 2.5
... Show MoreThere are still areas around the world suffer from severe shortage of freshwater supplies. Desalination technologies are not widely used due to their high energy usage, cost, and environmental damaging effects. In this study, a mathematical model of single-bed adsorption desalination system using silica gel-water as working pair is developed and validated via earlier experiments. A very good match between the model predictions and the experimental results is recorded. The objective is to reveal the factors affecting the productivity of fresh water and cooling effect in the solar adsorption system. The proposed model is setup for solving within the commercially-available software (Engineering Equation Solver). It is implemented to so
... Show MoreEnvironmental exposures to lead remain a serious problem in the developing and industrializing countries. Children are the highest risk aged-group for lead poisoning. This study was designed to assess lead exposure in Al-Fallujah city by analyzing blood lead levels in children and adults and to explain the relationship between blood lead levels, hematological parameters and ferritin levels in the children. The study was performed on-(90) subjects, (65children and 25 adults).Venous blood samples were taken for estimation of hematological parameters, serum ferritin levels and blood lead levels. The children group was subdivided into four groups as: group (A) (low ferritin, low Hb), group (B) (low ferritin, normal Hb), group (C) (normal fer
... Show More