Assessment of Radiological Air Contamination for Selected Places at Al-Tuwaitha Nuclear Site during Winter and Spring

This study presents the results of atmospheric particulates sampling using high volume air sampler for selected places at Al Tuwaitha nuclear site. The collected samples were analyzed for gross alpha /beta radioactivity using Ludlum model 3030 and measurement particles activity in Al Tuwaitha nuclear site and the surrounding areas for the period from 28/12/2016 to 13/4/2017.The measurement of activity concentrations ranged from (0.42±0.03 to 4.18±0.13) Bq/m3 for alpha particles and from(0.93±0.06 to 9.21±0.26) Bq/m3for beta particles. The activity concentration of nuclides inversely proportional with air temperature and wind speed while humidity is directly proportional with it. Highest value of activity concentration has been found at(Near nuclear and radiation safety directorate/ In the center of planning department/T9)while the lowest value has been found at (the right side of Nuclear application and researches directorate / building 61/T42). The results of this study show that the region has natural nuclides which are the daughters of the two decay series, namely the thorium and the uranium series. In both cases, it is a radioactive Radon isotope which can escape from the soil and ascend into the air.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jun 24 2022
Journal Name
Iraqi Journal Of Science
Computation of Climatic Water Balance for Greater Musaiyab Project Site in Babylon Governorate- Central of Iraq

The meteorological data recorded in Al-Hilla station for the period (1984-2014) were used to describe the climatic condition of the Greater Musaiyab Project lies in Babylon Governorate, 90Km southern of Baghdad City, central of Iraq. This study found that the summation of rainfall is (112.323 mm), average of relative humidity (47.44%), temperature (25.55 C◦), sunshine (8.748 h/day) and the total of evaporation is (2268.463 mm). In this research, three classifications were applied to find the type of climate in the study area. The results of the climate classification show that, the climate of study area is characterized by dry and relatively hot in summer, and cold with low rain in winter. Thornthwiat equation was used to determine the

... Show More
View Publication Preview PDF
Publication Date
Sun Nov 01 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
The effect of using Nano iron oxide in radiological shielding
Abstract<p>In this study, some attenuation parameters of gamma shields were studied. This shields consisting of composite materials of Unsaturated polyester as a base material and Nano iron oxide (Fe<sub>2</sub>O<sub>3</sub>) and, micro iron (Fe) as reinforcement materials at different percentages (1, 3,5,7and 9)wt%, and with different thickness (1, 1.5, 2, 2.5, 3, 3.5and 4) cm. The results showed that the use of nanoparticles is better than the microparticales in the field of radiation shielding. It has been shown that the values of attenuation parameters of gamma it bitter in the case of nanoparticles than case of the use of micro material.</p>
Scopus (3)
Crossref (2)
Scopus Crossref
View Publication
Publication Date
Thu Feb 28 2019
Journal Name
Iraqi Journal Of Science
The radiological effects of dust storms in Baghdad- Ramadi area

Twelve storm dust samples were collected from three cities in Iraq. The samples were collected in the same time during big storms which hit Iraq in summer, 2012 and 2013.  The deposited dust on 4 by 4 nylon sheet on surfaces of selected buildings in cities of Baghdad, Fallujah and Al-Ramadi were collected. Each sample was put in sealed Marinilli beaker and kept for 4 weeks to reach the equilibrium state between radium and its short half-life daughters. Gamma spectrometry system based on HPGe was used for analysis of natural and artificial radionuclides in the dust. The activities of natural radionuclides were found to be ranged between 13-19 Bq/kg, 9-14 Bq/kg and 200-240 Bq/kg for Ra-226, Th-232 and K-40 respectively, while Cs-137 w

... Show More
View Publication Preview PDF
Publication Date
Fri Dec 01 2023
Journal Name
Iraqi Journal Of Physics
Study of the Symmetry Energy and the Nuclear Equation of State for 13O -13B and 13N-13C Mirror Nuclei

In parallel with the shell model using the harmonic oscillator's single-particle wave functions, the Hartree-Fock approximation was also used to calculate the neutron skin thickness, the mirror charge radii, and the differences in proton radii for 13O-13B and 13N-13C mirror nuclei. The calculations were done for both mirror nuclei in the psdpn model space. Depending on the type of potential used, the calculated values of skin thickness are affected. The symmetry energy and the symmetry energy's slope at nuclear saturation density were also determined, and the ratio of the density to the saturation density of nuclear matter and the symmetry energy has a nearly linear correlation. The mirror ener

... Show More
Crossref
View Publication Preview PDF
Publication Date
Sat Feb 01 2014
Journal Name
Journal Of Engineering
Assessment Efficiency Evaluation of Al-Diwaniya Sewage Treatment Plant in Iraq

This study aims to evaluate the performance of the sewage treatment plant in Al- Diwaniya, one of cities in the southern part in Iraq. This evaluation could be used to facilitate effluent quality assessment or optimal process control of the plant. The influent reaching the plant is considered a medium to strong in strength with BOD5/COD ratio in the range 0.23 and 0.69 which can be considered an easily degradable sewage by the biological processes performed by the activated sludge unit. The quality of the effluent was found to be higher than the Iraqi standards for disposal to water bodies. The BOD5/COD ratios of the treated sewage varied over a wide range as low of 0.13 to 1.48 indicating operational problems in the plant. Regressio

... Show More
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Assessment Efficiency Evaluation of Al-Diwaniya Sewage Treatment Plant in Iraq

This study aims to evaluate the performance of the sewage treatment plant in Al-Diwaniya, one of cities in the southern part in Iraq. This evaluation could be used to facilitate effluent quality assessment or optimal process control of the plant. The influent reaching the plant is considered a medium to strong in strength with BOD5/COD ratio in the range 0.23 and 0.69 which can be considered an easily degradable sewage by the biological processes performed by the activated sludge unit. The quality of the effluent was found to be higher than the Iraqi standards for disposal to water bodies. The BOD5/COD ratios of the treated sewage varied over a wide range as low of 0.13 to 1.48 indicating operational problems in the plant. Regression ana

... Show More
Crossref (1)
Crossref
View Publication Preview PDF
Publication Date
Tue Jun 30 2015
Journal Name
Al-kindy College Medical Journal
Epidemiological characteristics of acute symptomatic hepatitis A in Al Alwyia pediatric teaching hospital during 2013

ABSTRACTBackground: Concerns about hepatitis A infections is increasing worldwide specially after improving economic and sanitary conditions in many countries making older age groups who escape infection on early life vulnerable to infection.Objectives: The objectives were to estimate the frequency of hepatitis A among children consulting Al Alwyia pediatric Teaching Hospital during the year 2013 and to study some demographic characteristics of the disease.Methods: This cross - sectional hospital -based study wasconducted during 2013-2014 and include pediatric patients(43525 patients) who consult Al Alwyia pediatric hospitalduring that time. The outcome is total IgM antibodies tohepatitis A virus detected using Enzyme Linked FluorescentA

... Show More
View Publication Preview PDF
Publication Date
Thu May 18 2023
Journal Name
Journal Of Engineering
Experimental Investigation for TiO2 nanoparticles as a Lubricant-Additive for a Compressor ofWindow Type Air-Conditioner

The coefficient of performance of a window type Air-Conditioner system can be improved if a reduction in the work of compressor can be achieved by a suitable technique. The present study investigates the effect of dispersing a low concentration of TiO2 nanoparticles in the mineral oil based lubricant, as well as on the overall performance of a window type Air-Conditioner system using R22 as the working fluid. An enhancement in the COP of the refrigeration system has been observed and the existence of an optimum volume fraction noticed, with low concentrations of nanoparticles suspended in the mineral oil. Results showed that the average compressor work reduced by 13.3%, which ultimately resulted in an increase of 11.99% in the COP due to

... Show More
Crossref (4)
Crossref
View Publication Preview PDF
Publication Date
Sun Sep 01 2019
Journal Name
Civil Engineering Journal
Simulation and Assessment of Groundwater for Domestic and Irrigation Uses

The alluvial fan of Mandali located between latitude 30˚45’00” N longitude 45˚30’00” E in east of Diyala Governorate, Iraq. Thirty-five wells were identified in the study area with average depth of 84 m and estimated area of 21550 ha. A three-dimensional conceptual model was prepared by using GMS program. From wells cross sections, four geological layers have been identified. The hydraulic conductivity of these layers was calculated for steady state condition, where the water levels for nine wells distributed over the study area were observed at same time. Afterward, PEST facility in the GMS was used to estimate the aquifer hydraulic characteristics. Other characteristics such as storage coefficient and specific yield have

... Show More
Scopus (48)
Crossref (43)
Scopus Clarivate Crossref
View Publication
Publication Date
Sun Jan 30 2022
Journal Name
Heat Transfer
Theoretical and experimental investigation of a heat pipe heat exchanger for energy recovery of exhaust air

Heat pipes and two‐phase thermosyphon systems are passive heat transfer systems that employ a two‐phase cycle of a working fluid within a completely sealed system. Consequently, heat exchangers based on heat pipes have low thermal resistance and high effective thermal conductivity, which can reach up to the order of (105 W/(m K)). In energy recovery systems where the two streams should be unmixed, such as airconditioning systems of biological laboratories and operating rooms in hospitals, heat pipe heat exchangers (HPHEs) are recommended. In this study, an experimental and theoretical study was carried out on the thermal performance of an air‐to‐air HPHE filled with two refrigerants as working fluids, R22 and R407c. The heat pipe he

... Show More