Commercially pure titanium (cpTi) is widely used as dental implant material although it was found that titanium exhibited high modulus of elasticity and the lower corrosion tendency in oral environment. Niobium(Nb) was chosen for this study as an alternative to cpTi implant material due to its bioinert behavior and good elastic modulus and moderate cost in addition to corrosion resistance. This study was done to evaluate the effect of biomimetic coating on the surface properties of the commercially pure titanium and niobium implants by in vitro and in vivo experiments. The in vitro study was involved etching the samples of each material in HCl then soaking in 10M NaOH aqueous solution. These samples were then immersed in a 5 times concentrated simulated body fluid for 14 days. Scanning Electron Microscope, Energy Dispersive X-ray, and X-Ray Diffraction tests were done to analyze surface changes. The in vivo study was done by the implantation of screw-shaped implants (two from each material, uncoated and the other was biomimetically coated) in the tibias of New Zealand rabbits. After 2 and 4 weeks of healing period, 20 rabbits were sacrificed for each period. A removal torque was done for ten animals in each group, whereas the other ten were used for histological testing and histomorphometric analysis with optical microscope.The in vitro experiments showed that the use of 14 days immersion in a concentrated simulated body fluid produced a layer of calcium phosphate on metal surfaces. The removal torque values and new bone formation were increased significantly in Nb than Ti, in coated than uncoated screws, and in 4 weeks than 2 weeks healing periods. The Nb implants had better biomechanical and biological properties than the commercially pure titanium implants and can be used as an alternative dental implant.
The use of destructive weapons in wars without restrictions and controls, which eat green and dry land, pollute the environment and cause genocide, has become the problem of the times.
International conventions for the protection of the environment during armed conflicts are characterized by generality, ambiguity, and open to interpretation by the participating states in the agreement, and each state interprets these texts to serve its interests, but the Islamic Sharia stipulates the prohibition of the use of these comprehensive destructive weapons in an unambiguous manner, As stated in the Holy Quran:
... Show MoreResearch summary
Islam protects the environment and civilians in peace and war, and in international humanitarian law protection of the environment and civilians in international conflicts only. As for wars and internal conflicts, it is not within the jurisdiction of international humanitarian law. In Islamic law, the principles of protecting the environment and civilians are fixed in all wars and conflicts, whether internal or external, local. or international.
Islam laid down moral principles in war, including:
- Preserving the environment and avoiding corruption in the land by burning trees and killing animals unnecessarily.
- Not to be exposed to non-combatants, including women, boys, the elderly, the disa
... Show MoreThe research aims to show the relationship between artificial intelligence in accounting education and its role in achieving sustainable development goals in the Kingdom of Bahrain. The research dealt with the role of artificial intelligence applications in accounting education at the University of Applied Sciences as a model for Bahraini universities to achieve sustainable development goals. The application of artificial intelligence in accounting education achieves seven of the seventeen sustainable development goals. It also concludes that there is an artificial intelligence infrastructure in the Kingdom of Bahrain, as it occupies a leading regional position in digital transformation, as Bahrain ranks first in the Arab world i
... Show MoreElectronic properties including (bond length, energy gap, HOMO, LUMO and density of state) as well as spectroscopic properties such like infrared, Raman scattering, force constant, reduced mass and longitu- dinal optical mode as a function of frequency are based on size and concentration of the molecular and nanostructures of aluminum nitride ALN, boron nitride BN and AlxB7-XN7 as nanotubes has calculated using Ab –initio approximation method dependent on density functional theory and generalized gradient approximation. The geometrical structure are calculated by using Gauss view 05 as a complementary program. Shows the energy gap of ALN, BN and AlxB7-XN7 as a function of the total number of atoms , start from smallest molecule to reached
... Show MoreMetalloendo peptidase is a neutral endopeptidase that cleaves peptides at the amino side of hydrophobic residues and inactivates several peptide hormones, including atrial natriuretic factor, giucagon, enkephalin, substance p, neurotensin, oxytocin, and bradykinin. It is also a major enzyme for the degradation of beta-amyloid. This study aimed to measure enzyme activity and compare it with other biochemical changes in sera patients with diabetic nephropathy. The study included 35 pathological samples of people with diabetic nephropathy, 24 samples from males and 11 samples from females, as well as the same number of healthy people as a comparison group of 15 males, 20 females, with the ages of both groups of patients with diabetic nephropat
... Show MoreDespite all the possibilities held by Iraq for the production of poultry , but there is low and clear in the level of production and a rise in costs and a decline in per capita consumption is due to a number of reasons, including poor investment , stop government subsides , dumping policies , market Bolmottagat imported , the contribution of the merchant squandering of national capacity , weak base material for the growth of this sector , the security situation and the crisis of energy and others .
Despite all this research has shown that there are great investment opportunities in this very sector of the market size and absorptive capacity of his and the growth of per capita income and level of cul
... Show MoreAbstract
The study aimed to prepare a practical guide for procedures for auditing the strategies of municipal institutions in achieving sustainable development by adopting the idea of the audit matrix through which a classified report is prepared according to the dimensions of sustainable development, by preparing a specialized audit program for the purpose of auditing strategies for achieving sustainable development and emptying the results of the application of each of the paragraphs The program in the audit matrix that was prepared for the purpose of determining the impact of each observation and linkin
... Show MoreBackground: The purpose of this study was to evaluate and compare centering ability and canal transportation of simulated S-shaped canals instrumented with four different types of rotary nickel-titanium systems. Materials and Methods: Forty simulated S-shaped canals in resin blocks were divided into four groups of ten each and were instrumented to an apical size 25 by different instrumentation technique using ProTaper Universal files (group A), ProTaperNext (group B), Reciproc (group C) and WaveOne (group D).Centering ability and canal transportation was measured at (11) measuring points from D0 to D10 bysuperimposion of the pre- and post-operative images obtained by using digital camera in standardized manner. An assessment of the canals
... Show MoreIn this research we investigated the corrosion behavior of the commertialy pure titanium and Ti-6Al-4V alloy that coated with hydroxyapatite by electrochemical deposition with applied voltage (6,9,12) Volt from aqueous solution containing Ca(NO3)2.H2O =7.0 gm/l , (NH4)2HPO4 =3.5 gm/l , Na(NO3)2 = 8.5 gm/l in order to improve the bonding strength of hydroxyapetite and medical metals and alloys and increasing the biocompatibility. The coating layer morphology was investigated by XRD, Optical microscope , and SEM tests, the corrosio tests was made by use senthesys simulated body fluid (SBF) , and we found that the propreate voltage for coatint on Ti was 9 Volt and for Ti-6Al-4Vwas12Volt.