Preferred Language
Articles
/
bsj-2458
Spectrophotometric Determination of Sulphite in Various Water Samples Via Chromium-1,5-Diphenylcarbazide Complex
...Show More Authors

A simple and rapid spectrophotometric method for the determination of sulphite SO3-2 is described. The method is based on the rapid reduction of known amount of chromate CrO4-2 in the presence of sulphite in acidic medium of 2N H2SO4. The amount of excess of chromate was measured after it reactions with 1,5-diphenylcarbazide which finally gives a pink-violet, water soluble and stable complex, which exhibit a maximum absorption at 542 nm. Beer's law was obeyed in the concentration range from 0.004-6.0 µg of sulphite in a final volume of 25 ml with a molar absorbtivity of 4.64×104 l.mol-1.cm-1, Sandal's sensitivity index of 0.001724 ?g .cm-2 and relative standard deviation of ±0.55 - ±0.83 depending on the concentration level. The present method has been developed for the determination of sulphite in the presence of thiosulphate. Good recoveries of sulphite from various water samples are achieved using the proposed method.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Sep 16 2019
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Determination of Ibuprofen in Pharmaceutical Formulations Using Differential Pulse Polarography
...Show More Authors

     A reliable differential pulse polarographic (DPP) method has been developed and applied for the determination of ibuprofen IBU in dosage form with dropping mercury electrode (DME) versus Ag/AgCl. The best peak was found at cathodic peak of -1.18 V in phosphate buffer at pH=4 and 0.025M of KNO3 as supporting electrolyte. In order to obtaine the highest sensitivity, instrumental and experimental parameters were examined including the type and concentration of supporting electrolyte, pH of buffer solution, pulse amplitude and voltage step time. Diffusion current showed a direct linear relationship to ibuprofen concentration in the range of (5 – 30) μg. mL-1 (2.43× 10-5

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Jun 30 2007
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Determination of Volumetric Mass Transfer Coefficient in Fixed Bed Adsorption
...Show More Authors

This work was conducted to determine the volumetric mass transfer coefficient (Ky.a) infixed bed adsorption using hexane-benzene mixture by adsorption onto a fixed bed of white silica gel. Benzene concentration was measured by gas chromatography. The effect of feed flow rate and initial concentration of benzene in hexane-benzene mixture on the volumetric mass transfer coefficient and on the adsorption capacity of silica gel was investigated.

In general, the volumetric mass transfer coefficient increases with increasing hexane flow rate, and with increasing initial concentration of benzene in the mixture. The ultimate value of (Ky.a) was at 53 ml/min of hexane flow rate with benzene initial concentration of (6.53 wt. %), and it wa

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 03 2012
Journal Name
Baghdad Science Journal
Spectrofluorimetric method for the determination of glibenclamide in pharmaceutical formulations
...Show More Authors

A sensitive spectrofluorimetric method for the determination of glibenclamide in its tablet formulations has been proposed. The method is based on the dissolving of glibenclamide in absolute ethanol and measuring the native fluorescence at 354 nm after excitation at 302 nm. Beers law is obeyed in the concentration of 1.4 to 10 µg.ml-1 of glibenclamide with a limit of detection (LD) of 0.067 µg.ml-1 and a standard deviation of 0.614. The range percent recoveries (N=3) is 94 - 103.

View Publication Preview PDF
Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Partial Differential Equations In Applied Mathematics
Determination of time-dependent coefficient in time fractional heat equation
...Show More Authors

View Publication
Scopus (13)
Crossref (3)
Scopus Crossref
Publication Date
Mon Sep 25 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Potentiometric Determination of Iodide in Magnesium Fluoride by Iodide Electrode
...Show More Authors

Iodide Ø¢ in samples Ø¢ containing Ø¢ magnesium Ø¢ fluoride Ø¢ was Ø¢ determinedØ¢  Ø¢ by using iodide selective Ø¢ electrode. Ø¢ Detecting Ø¢ the limit for iodide determination

was around Ø¢ 5x1 oآ·5Ø¢ Ø¢ M with a standard Ø¢ deviation Ø¢ ranged Ø¢ from Ø¢ Ø¢Â± 0.3 to آ± 0.6.

QuantitativeØ¢  Ø¢ methodsØ¢  Ø¢ including; standard Ø¢ additionØ¢  Ø¢ method, Ø¢ Potentiometric

titration Ø¢ by using a Gran plot paper for an equivalent Ø¢ point determination and a Ø¢ directØ¢  Ø¢ methodØ¢&n

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 25 2020
Journal Name
International Journal Of Drug Delivery Technology
Development and Characterization of Controlled Release Tablets of Candesartan Cilexetil/ β‑Cyclodextrin Inclusion Complex
...Show More Authors

Objective: Matrix tablet approach is one of the delivery systems intended for poorly water-soluble drugs, like candesartan cilexetil (CC). CC is a class II drug used for the treatment of hypertension. Methods: Matrix tablets from (F1x to F18z) were prepared in the presence of β‑cyclodextrin. Matrix tablet formulation ensures control release of the drug and higher dissolution by β‑cyclodextrin. Fourier transform infrared spectroscopy (FTIR), and differential scanning calorimetry (DSC) were used to study compatibility. Results: The angle of repose determination showed good flow for most of the formulas, besides having good compressibility. Weight variation test for all formulas showed accepted value. Drug content measurement sho

... Show More
Scopus (6)
Crossref (2)
Scopus Crossref
Publication Date
Thu Jun 25 2020
Journal Name
International Journal Of Drug Delivery Technology
Development and Characterization of Controlled Release Tablets of Candesartan Cilexetil/ β‑Cyclodextrin Inclusion Complex
...Show More Authors

Objective: Matrix tablet approach is one of the delivery systems intended for poorly water-soluble drugs, like candesartan cilexetil (CC). CC is a class II drug used for the treatment of hypertension. Methods: Matrix tablets from (F1x to F18z) were prepared in the presence of β‑cyclodextrin. Matrix tablet formulation ensures control release of the drug and higher dissolution by β‑cyclodextrin. Fourier transform infrared spectroscopy (FTIR), and differential scanning calorimetry (DSC) were used to study compatibility. Results: The angle of repose determination showed good flow for most of the formulas, besides having good compressibility. Weight variation test for all formulas showed accepted value. Drug content measurement sho

... Show More
View Publication
Scopus (6)
Crossref (2)
Scopus Crossref
Publication Date
Tue Dec 01 2020
Journal Name
2020 5th Ieee International Conference On Recent Advances And Innovations In Engineering (icraie)
The New Way of Estimating the PCB's Lifetime of Fatigue using the Principle of Linear Accumulated Damage in Various Boundary Condition
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Thu Jun 23 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Flow Injection Spectrophotometric Technique for Determining of Genistein in Pure and Supplements Formulations Through Diazotization Coupling Reaction
...Show More Authors

Genistein (GEN) is The major isoflavone found in soybeans, has a number of cardiovascular health benefits, Postmenopausal syndrome and osteoporosis. A direct flow injection analysis method for estimation of (GEN) in pure and supplements formulation . This system is based on diazotization coupling reactions between procaine penciline (PR) and genistein in basic medium, they formed yellow dyes have maximum absorption at 416 nm. Calibration curve were constructed over different GEN concentrations, linearity for GEN was 10-100 µg.mL-1 and detection limits of 1.51 ?g/mL. In the FIA technique, all analytical factors were analyzed and optimized. The established method was successfully used to determine GEN in the formulations of its supplement

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Wed Oct 01 2014
Journal Name
Iraqi Journal Of Science
Removal of chromium (III) ions from its aqueous solution on adsorbent surfaces: Charcoal, Attapulgite and Date Palm Leaflet Powder
...Show More Authors

In the present work, a study is carried out to remove chromium (III) from aqueous solution by: activated charcoal, attapulgite and date palm leaflet powder (pinnae). The effect of various parameters such as contact time, and temperature has been studied. The isotherm equilibrium data were well fitted by Freundlich and Langmuir isotherm models. The adsorption capacity of chromium (III) that was observed by activated charcoal, attapulgite and date palm leaflet powder (pinnae) increased with the rise of temperature when the concentrations of Cr (III) were 600, 700 and 100mg/L respectively. The greatest adsorption capacity ofactivated charcoal, attapulgite and date palm leaflet powder (pinnae) at 10°C was 7.51, 5.39 and 0.77mg.gˉ¹ respective

... Show More