Preferred Language
Articles
/
bsj-2444
Effects of Gas Flow on Spectral Properties of Plasma Jet Induced by Microwave
...Show More Authors

In this paper, a construction microwave induced plasma jet(MIPJ) system was used to produce a non-thermal plasma jet at atmospheric pressure, at standard frequency of 2.45 GHz and microwave power of 800 W. The working gas Argon (Ar) was supplied to flow through the torch with adjustable flow rate using flow meter regulator. The influence of the MIPJ parameters such as applied voltage and argon gas flow rate on macroscopic microwave plasma parameters were studied. The macroscopic parameters results show increasing of microwave plasma jet length with increasing of applied voltage, argon gas flow rate where the plasma jet length exceed 12 cm as maximum value. While the increasing of argon gas flow rate will cause increasing into the argon gas temperature, where argon gas temperature the exceed 350 ? as maximum value and study the effect of gas flow rate on the optical properties

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Mar 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Effects of Drying Conditions on the Properties of Dried Particles of Powdered steep Liquor
...Show More Authors

View Publication Preview PDF
Publication Date
Sat Jun 19 2021
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Possible Protective Effects of Lutein against Ciprofloxacin Induced Bone Marrow Toxicity in Rats
...Show More Authors

Ciprofloxacin, which is a second generation of fluoroquinolone and one of the most effective and widely used drugs within fluoroquinolone. Unfamiliar adverse effects of ciprofloxacin such as bone marrow (BM) suppression, thrombocytopenia, anemia, agranulocytosis, renal failure, and others observed. Lutein, is a xanthophyll (an oxygenated carotenoid), was focused by most studies as it has a strong antioxidant activity in vitro; and also, it has been associated with reducing the risk of the age-related disorders. The current study was designed to describe the role of apoptosis through the measurement of Bcl-2 associated X protein (Bax) marker, as mechanisms of bone marrow toxicity induced by ciprofloxacin and to find whether lutei

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Thu Dec 06 2018
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Effects of Vitamin E and Q10 Supplementation against Doxorubicin-Induced Neurotoxicity in Rats
...Show More Authors

View Publication Preview PDF
Scopus (8)
Crossref (5)
Scopus Crossref
Publication Date
Sun Mar 17 2019
Journal Name
Baghdad Science Journal
Influence of Cold Atmospheric Plasma on Acinetobacter baumannii
...Show More Authors
  1. baumannii is an aerobic gram negative coccobacilli, it is considered multidrug resistance pathogen (MDR) and causes several infections that are difficult to treat. This study is aims to employ physical methods in sterilization and inactivation of A. baumannii, as an alternative way to reduce the using of drugs and antibiotics.
  2.             Cold Atmospheric Plasma was generated by one electrode at 20KV, 4 power supply and distance between electrode and sample was fixed on 1mm. A. baumannii (ATCC 19704 and HHR1) were exposed to  Dielectric Barrier Discharge type of Cold Atmospheric Plasma (DBD-CAP) for several periods

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees21gr
Effect of cold atmospheric plasma on the wound of diabetic rats by FE-DBD system
...Show More Authors

This study explains the effect of non-thermal (cold) plasma on wound of diabetic rats by (FE-DBD) system, 3cm probe diameter is used. The output power was ranged from (12-20) W. The effect of non-thermal plasma on wounds of a diabetic was observed with different exposure durations (20,30) sec., the plasma exposure duration decreases the sugar level in blood and the diameter of the wound. These results indicate the cold plasma can be used to enhance the insulin level (i.e., blood sugar) and wounds treatment.

View Publication
Scopus Crossref
Publication Date
Thu Apr 27 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
A Study of Structure and Optical Properties of ZnO Thin Films Deposited by Using Thermal Evaporation Technique under Different Flow Rate of Oxygen O2
...Show More Authors

 Zinc oxide (ZnO) transparent thin films with different oxygen flow rates (0.5, 1.0, and 1.5)Litter/min. were prepared by thermal evaporation technique on glass substrate at a temperature of 200℃ with rate (10±2)nm sec-1,  The crystallinity and structure of these films were analyzed  by X-ray diffraction (XRD). It exhibits a polycrystalline hexagonal wurtzite structure and the preferred orientation along (002) plane. The Optical properties of ZnO were determined through the optical transmission method using ulta violet–Visible spectrophotometer with in wave length (300-1100)nm. The optical transmittance of the ZnO films increases from 75% to 85% with increase flow rate of O2, and the optical band gap of ZnO

... Show More
View Publication Preview PDF
Publication Date
Sat Jul 01 2023
Journal Name
Journal Of Engineering
Review of Jet Grouting Practice around the World
...Show More Authors

This paper aims to make a historical review of jet grouting techniques and encountered problems at different sites in several countries.  This review is a good guide to understanding the performance and limitations of improved soils or lands. The basic concept of jet grouting technology is to use cement as a binder to accelerate the hardening process of an admixture of material grout and soil. The different case history was conducted in both sand soil and clay soil in the horizontal and vertical direction. Other papers on field construction showed that the grout can be gelled within 5-10 minutes. Due to different cases and studies, these will help improve soil by supporting the foundation load with a minimal settlement.

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Influence of non-thermal argon plasma needle on blood coagulation
...Show More Authors

Non-thermal argon plasma needle at atmospheric pressure was
constructed. The experimental setup was based on a simple and low
cost electric component that generates a sufficiently high electric
field at the electrodes to ionize the argon gas which flow at
atmospheric pressure. A high AC power supply was used with 1.1
kV and 19.57 kHz. Non-thermal Argon plasma used on blood
samples to show the ability of non-thermal plasma to promote blood
coagulation. Three tests have been done to show the ability of plasma
to coagulate both normal and anti-coagulant blood. Each blood
sample has been treated for varying time from 20sec. to 180sec. at
different distances. The results of the current study showed that the
co

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Preventive Effects of Different Doses of Pentoxyfilline Against CCl4-Induced Liver Toxicity in Rats
...Show More Authors

The liver protective effects of pentoxifylline were studied through pre-treatment of rats with various intraperitoneal (IP) doses (25, 50 and 100mg/kg/day) 14 days before induction of liver toxicity by carbon tetrachloride (CCl4). The parameters of oxidative stress, malondialdehyde (MDA) and reduced glutathione (GSH) were measured in liver homogenate in addition to histopathological examinations.  Analysis of data revealed significant amelioration of oxidative stress in groups of animals pre-treated with different doses of pentoxifylline (PTX) compared to group of animals intoxicated by CCl4 as evidenced by lowering MDA contents and elevation of GSH levels in liver tissue homogenate but the levels still signifi

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Aug 31 2019
Journal Name
Iraqi Journal Of Physics
The Q-switched Nd:YAG laser shock processing effects on mechanical properties of C86400 Cu-Zn alloy: Q-switched Nd:YAG laser shock processing effects on mechanical properties of C86400 Cu-Zn alloy
...Show More Authors

The aim of this paper is to investigate the effects of Nd:YAG laser shock processing (LSP) on micro-hardness and surface roughness of 86400Cu-Zn alloy. X-ray fluorescence technique was used to analyze the chemical composition of this alloy. LSP treatment was performed with a Q-switched Nd: YAG laser with a wavelength of 1064 nm. The results show that laser shock processing can significantly increase. The micro-hardness and surface roughness of the LSP-treated sample. Vickers diamond indenter was used to measure the micro-hardness of all samples with different laser pulse energy and the different number of laser pulses. It is found that the metal hardness can be significantly increased to more than 80% by increasing the laser energy and t

... Show More
View Publication Preview PDF
Crossref (1)
Crossref